diff options
author | Ashok Nagarajan <ashok@cozybit.com> | 2012-04-30 14:20:30 -0700 |
---|---|---|
committer | John W. Linville <linville@tuxdriver.com> | 2012-05-08 21:53:57 -0400 |
commit | 57aac7c51c07ca7a2361477f352af422259301bd (patch) | |
tree | b7c4e8a79335d11a46e667d1d555d537faae7a7e /net/mac80211/mesh_plink.c | |
parent | 431e31542383b71bc5f2642572a1e6ef07f1bb87 (diff) | |
download | blackbird-op-linux-57aac7c51c07ca7a2361477f352af422259301bd.tar.gz blackbird-op-linux-57aac7c51c07ca7a2361477f352af422259301bd.zip |
mac80211: Implement HT mixed protection mode
Section 9.23.3.5 of IEEE 80211s standard describes the protection rules for
HT mesh STA in a MBSS. Three HT protection modes are supported for now:
non-HT mixed mode - is selected if any non-HT peers are present in our MBSS.
20MHz-protection mode - is selected if all peers in our 20/40MHz MBSS support
HT and atleast one HT20 peer is present.
no-protection mode - is selected otherwise.
This is a limited implementation of 9.23.3.5, which only considers mesh peers
when determining the HT protection mode. Station's channel_type needs to be
maintained.
Signed-off-by: Ashok Nagarajan <ashok@cozybit.com>
Reviewed-by: Thomas Pedersen <thomas@cozybit.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
Diffstat (limited to 'net/mac80211/mesh_plink.c')
-rw-r--r-- | net/mac80211/mesh_plink.c | 83 |
1 files changed, 76 insertions, 7 deletions
diff --git a/net/mac80211/mesh_plink.c b/net/mac80211/mesh_plink.c index 6209327840f7..2e0ae7310697 100644 --- a/net/mac80211/mesh_plink.c +++ b/net/mac80211/mesh_plink.c @@ -105,6 +105,66 @@ static struct sta_info *mesh_plink_alloc(struct ieee80211_sub_if_data *sdata, return sta; } +/** mesh_set_ht_prot_mode - set correct HT protection mode + * + * Section 9.23.3.5 of IEEE 80211s standard describes the protection rules for + * HT mesh STA in a MBSS. Three HT protection modes are supported for now, + * non-HT mixed mode, 20MHz-protection and no-protection mode. non-HT mixed + * mode is selected if any non-HT peers are present in our MBSS. + * 20MHz-protection mode is selected if all peers in our 20/40MHz MBSS support + * HT and atleast one HT20 peer is present. Otherwise no-protection mode is + * selected. + */ +static u32 mesh_set_ht_prot_mode(struct ieee80211_sub_if_data *sdata) +{ + struct ieee80211_local *local = sdata->local; + struct sta_info *sta; + u32 changed = 0; + u16 ht_opmode; + bool non_ht_sta = false, ht20_sta = false; + + if (local->_oper_channel_type == NL80211_CHAN_NO_HT) + return 0; + + rcu_read_lock(); + list_for_each_entry_rcu(sta, &local->sta_list, list) { + if (sdata == sta->sdata && + sta->plink_state == NL80211_PLINK_ESTAB) { + switch (sta->ch_type) { + case NL80211_CHAN_NO_HT: + mpl_dbg("mesh_plink %pM: nonHT sta (%pM) is present", + sdata->vif.addr, sta->sta.addr); + non_ht_sta = true; + goto out; + case NL80211_CHAN_HT20: + mpl_dbg("mesh_plink %pM: HT20 sta (%pM) is present", + sdata->vif.addr, sta->sta.addr); + ht20_sta = true; + default: + break; + } + } + } +out: + rcu_read_unlock(); + + if (non_ht_sta) + ht_opmode = IEEE80211_HT_OP_MODE_PROTECTION_NONHT_MIXED; + else if (ht20_sta && local->_oper_channel_type > NL80211_CHAN_HT20) + ht_opmode = IEEE80211_HT_OP_MODE_PROTECTION_20MHZ; + else + ht_opmode = IEEE80211_HT_OP_MODE_PROTECTION_NONE; + + if (sdata->vif.bss_conf.ht_operation_mode != ht_opmode) { + sdata->vif.bss_conf.ht_operation_mode = ht_opmode; + changed = BSS_CHANGED_HT; + mpl_dbg("mesh_plink %pM: protection mode changed to %d", + sdata->vif.addr, ht_opmode); + } + + return changed; +} + /** * __mesh_plink_deactivate - deactivate mesh peer link * @@ -302,11 +362,14 @@ static struct sta_info *mesh_peer_init(struct ieee80211_sub_if_data *sdata, else memset(&sta->sta.ht_cap, 0, sizeof(sta->sta.ht_cap)); - if (elems->ht_operation) + if (elems->ht_operation) { if (!(elems->ht_operation->ht_param & IEEE80211_HT_PARAM_CHAN_WIDTH_ANY)) sta->sta.ht_cap.cap &= ~IEEE80211_HT_CAP_SUP_WIDTH_20_40; + sta->ch_type = + ieee80211_ht_oper_to_channel_type(elems->ht_operation); + } rate_control_rate_init(sta); spin_unlock_bh(&sta->lock); @@ -495,9 +558,10 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m enum plink_event event; enum ieee80211_self_protected_actioncode ftype; size_t baselen; - bool deactivated, matches_local = true; + bool matches_local = true; u8 ie_len; u8 *baseaddr; + u32 changed = 0; __le16 plid, llid, reason; #ifdef CONFIG_MAC80211_VERBOSE_MPL_DEBUG static const char *mplstates[] = { @@ -783,7 +847,8 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m sta->plink_state = NL80211_PLINK_ESTAB; spin_unlock_bh(&sta->lock); mesh_plink_inc_estab_count(sdata); - ieee80211_bss_info_change_notify(sdata, BSS_CHANGED_BEACON); + changed |= mesh_set_ht_prot_mode(sdata); + changed |= BSS_CHANGED_BEACON; mpl_dbg("Mesh plink with %pM ESTABLISHED\n", sta->sta.addr); break; @@ -818,7 +883,8 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m sta->plink_state = NL80211_PLINK_ESTAB; spin_unlock_bh(&sta->lock); mesh_plink_inc_estab_count(sdata); - ieee80211_bss_info_change_notify(sdata, BSS_CHANGED_BEACON); + changed |= mesh_set_ht_prot_mode(sdata); + changed |= BSS_CHANGED_BEACON; mpl_dbg("Mesh plink with %pM ESTABLISHED\n", sta->sta.addr); mesh_plink_frame_tx(sdata, @@ -836,13 +902,13 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m case CLS_ACPT: reason = cpu_to_le16(WLAN_REASON_MESH_CLOSE); sta->reason = reason; - deactivated = __mesh_plink_deactivate(sta); + __mesh_plink_deactivate(sta); sta->plink_state = NL80211_PLINK_HOLDING; llid = sta->llid; mod_plink_timer(sta, dot11MeshHoldingTimeout(sdata)); spin_unlock_bh(&sta->lock); - if (deactivated) - ieee80211_bss_info_change_notify(sdata, BSS_CHANGED_BEACON); + changed |= mesh_set_ht_prot_mode(sdata); + changed |= BSS_CHANGED_BEACON; mesh_plink_frame_tx(sdata, WLAN_SP_MESH_PEERING_CLOSE, sta->sta.addr, llid, plid, reason); break; @@ -889,4 +955,7 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m } rcu_read_unlock(); + + if (changed) + ieee80211_bss_info_change_notify(sdata, changed); } |