summaryrefslogtreecommitdiffstats
path: root/fs/nfs/pnfs.c
diff options
context:
space:
mode:
authorAndy Adamson <andros@netapp.com>2012-05-23 05:02:37 -0400
committerTrond Myklebust <Trond.Myklebust@netapp.com>2012-05-24 16:15:49 -0400
commitd23d61c8d351f5ced44ce87caf1fa3baab4c3f89 (patch)
tree4d35f14887a3a61dcfc2c76a64ce3e84655f949e /fs/nfs/pnfs.c
parent2701d086dbfca03b2d28b25c6dc11dd78d0e26ad (diff)
downloadblackbird-op-linux-d23d61c8d351f5ced44ce87caf1fa3baab4c3f89.tar.gz
blackbird-op-linux-d23d61c8d351f5ced44ce87caf1fa3baab4c3f89.zip
NFSv4.1 test the mdsthreshold hint parameters
Signed-off-by: Andy Adamson <andros@netapp.com> Signed-off-by: Trond Myklebust <Trond.Myklebust@netapp.com>
Diffstat (limited to 'fs/nfs/pnfs.c')
-rw-r--r--fs/nfs/pnfs.c79
1 files changed, 79 insertions, 0 deletions
diff --git a/fs/nfs/pnfs.c b/fs/nfs/pnfs.c
index 6620606f2687..b8323aa7b543 100644
--- a/fs/nfs/pnfs.c
+++ b/fs/nfs/pnfs.c
@@ -936,6 +936,81 @@ pnfs_find_lseg(struct pnfs_layout_hdr *lo,
}
/*
+ * Use mdsthreshold hints set at each OPEN to determine if I/O should go
+ * to the MDS or over pNFS
+ *
+ * The nfs_inode read_io and write_io fields are cumulative counters reset
+ * when there are no layout segments. Note that in pnfs_update_layout iomode
+ * is set to IOMODE_READ for a READ request, and set to IOMODE_RW for a
+ * WRITE request.
+ *
+ * A return of true means use MDS I/O.
+ *
+ * From rfc 5661:
+ * If a file's size is smaller than the file size threshold, data accesses
+ * SHOULD be sent to the metadata server. If an I/O request has a length that
+ * is below the I/O size threshold, the I/O SHOULD be sent to the metadata
+ * server. If both file size and I/O size are provided, the client SHOULD
+ * reach or exceed both thresholds before sending its read or write
+ * requests to the data server.
+ */
+static bool pnfs_within_mdsthreshold(struct nfs_open_context *ctx,
+ struct inode *ino, int iomode)
+{
+ struct nfs4_threshold *t = ctx->mdsthreshold;
+ struct nfs_inode *nfsi = NFS_I(ino);
+ loff_t fsize = i_size_read(ino);
+ bool size = false, size_set = false, io = false, io_set = false, ret = false;
+
+ if (t == NULL)
+ return ret;
+
+ dprintk("%s bm=0x%x rd_sz=%llu wr_sz=%llu rd_io=%llu wr_io=%llu\n",
+ __func__, t->bm, t->rd_sz, t->wr_sz, t->rd_io_sz, t->wr_io_sz);
+
+ switch (iomode) {
+ case IOMODE_READ:
+ if (t->bm & THRESHOLD_RD) {
+ dprintk("%s fsize %llu\n", __func__, fsize);
+ size_set = true;
+ if (fsize < t->rd_sz)
+ size = true;
+ }
+ if (t->bm & THRESHOLD_RD_IO) {
+ dprintk("%s nfsi->read_io %llu\n", __func__,
+ nfsi->read_io);
+ io_set = true;
+ if (nfsi->read_io < t->rd_io_sz)
+ io = true;
+ }
+ break;
+ case IOMODE_RW:
+ if (t->bm & THRESHOLD_WR) {
+ dprintk("%s fsize %llu\n", __func__, fsize);
+ size_set = true;
+ if (fsize < t->wr_sz)
+ size = true;
+ }
+ if (t->bm & THRESHOLD_WR_IO) {
+ dprintk("%s nfsi->write_io %llu\n", __func__,
+ nfsi->write_io);
+ io_set = true;
+ if (nfsi->write_io < t->wr_io_sz)
+ io = true;
+ }
+ break;
+ }
+ if (size_set && io_set) {
+ if (size && io)
+ ret = true;
+ } else if (size || io)
+ ret = true;
+
+ dprintk("<-- %s size %d io %d ret %d\n", __func__, size, io, ret);
+ return ret;
+}
+
+/*
* Layout segment is retreived from the server if not cached.
* The appropriate layout segment is referenced and returned to the caller.
*/
@@ -962,6 +1037,10 @@ pnfs_update_layout(struct inode *ino,
if (!pnfs_enabled_sb(NFS_SERVER(ino)))
return NULL;
+
+ if (pnfs_within_mdsthreshold(ctx, ino, iomode))
+ return NULL;
+
spin_lock(&ino->i_lock);
lo = pnfs_find_alloc_layout(ino, ctx, gfp_flags);
if (lo == NULL) {
OpenPOWER on IntegriCloud