summaryrefslogtreecommitdiffstats
path: root/drivers/scsi/lpfc/lpfc_init.c
diff options
context:
space:
mode:
authorJames Smart <jsmart2021@gmail.com>2018-10-23 13:41:01 -0700
committerMartin K. Petersen <martin.petersen@oracle.com>2018-11-06 20:42:50 -0500
commitcd71348ad75705aab857c098a74e99700e173b77 (patch)
treebd47db89038eccef64912af8901e4a61f10a37df /drivers/scsi/lpfc/lpfc_init.c
parentc47b6f2d54d40c053f6a15d52489eb9e1a319da2 (diff)
downloadblackbird-op-linux-cd71348ad75705aab857c098a74e99700e173b77.tar.gz
blackbird-op-linux-cd71348ad75705aab857c098a74e99700e173b77.zip
scsi: lpfc: Correct speeds on SFP swap
Supported speeds is not updated when SFP is removed or replaced Supported speed is obtained from lmt field in READ_CONFIG mailbox response. Driver updates supported speeds only once from PCI probe path. After that it is never updated. So, supported speeds remains the same till reboot or driver reload. When SFP is removed or inserted, driver gets SLI-Port Event ACQE. If SFP is removed, lmt wil have value 0. If a different SFP is inserted, lmt will have value according to its supported speeds. So, afterr SLI-Port Event ACQE handling path, send READ_CONFIG mailbox and update supported speeds. If READ_CONFIG fails, set supported speeds to unknown and log. Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: James Smart <jsmart2021@gmail.com> Reviewed-by: Hannes Reinecke <hare@suse.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Diffstat (limited to 'drivers/scsi/lpfc/lpfc_init.c')
-rw-r--r--drivers/scsi/lpfc/lpfc_init.c63
1 files changed, 46 insertions, 17 deletions
diff --git a/drivers/scsi/lpfc/lpfc_init.c b/drivers/scsi/lpfc/lpfc_init.c
index 20fa6785a0e2..df0ec52a9b56 100644
--- a/drivers/scsi/lpfc/lpfc_init.c
+++ b/drivers/scsi/lpfc/lpfc_init.c
@@ -4102,6 +4102,30 @@ finished:
return stat;
}
+void lpfc_host_supported_speeds_set(struct Scsi_Host *shost)
+{
+ struct lpfc_vport *vport = (struct lpfc_vport *)shost->hostdata;
+ struct lpfc_hba *phba = vport->phba;
+
+ fc_host_supported_speeds(shost) = 0;
+ if (phba->lmt & LMT_64Gb)
+ fc_host_supported_speeds(shost) |= FC_PORTSPEED_64GBIT;
+ if (phba->lmt & LMT_32Gb)
+ fc_host_supported_speeds(shost) |= FC_PORTSPEED_32GBIT;
+ if (phba->lmt & LMT_16Gb)
+ fc_host_supported_speeds(shost) |= FC_PORTSPEED_16GBIT;
+ if (phba->lmt & LMT_10Gb)
+ fc_host_supported_speeds(shost) |= FC_PORTSPEED_10GBIT;
+ if (phba->lmt & LMT_8Gb)
+ fc_host_supported_speeds(shost) |= FC_PORTSPEED_8GBIT;
+ if (phba->lmt & LMT_4Gb)
+ fc_host_supported_speeds(shost) |= FC_PORTSPEED_4GBIT;
+ if (phba->lmt & LMT_2Gb)
+ fc_host_supported_speeds(shost) |= FC_PORTSPEED_2GBIT;
+ if (phba->lmt & LMT_1Gb)
+ fc_host_supported_speeds(shost) |= FC_PORTSPEED_1GBIT;
+}
+
/**
* lpfc_host_attrib_init - Initialize SCSI host attributes on a FC port
* @shost: pointer to SCSI host data structure.
@@ -4129,23 +4153,7 @@ void lpfc_host_attrib_init(struct Scsi_Host *shost)
lpfc_vport_symbolic_node_name(vport, fc_host_symbolic_name(shost),
sizeof fc_host_symbolic_name(shost));
- fc_host_supported_speeds(shost) = 0;
- if (phba->lmt & LMT_64Gb)
- fc_host_supported_speeds(shost) |= FC_PORTSPEED_64GBIT;
- if (phba->lmt & LMT_32Gb)
- fc_host_supported_speeds(shost) |= FC_PORTSPEED_32GBIT;
- if (phba->lmt & LMT_16Gb)
- fc_host_supported_speeds(shost) |= FC_PORTSPEED_16GBIT;
- if (phba->lmt & LMT_10Gb)
- fc_host_supported_speeds(shost) |= FC_PORTSPEED_10GBIT;
- if (phba->lmt & LMT_8Gb)
- fc_host_supported_speeds(shost) |= FC_PORTSPEED_8GBIT;
- if (phba->lmt & LMT_4Gb)
- fc_host_supported_speeds(shost) |= FC_PORTSPEED_4GBIT;
- if (phba->lmt & LMT_2Gb)
- fc_host_supported_speeds(shost) |= FC_PORTSPEED_2GBIT;
- if (phba->lmt & LMT_1Gb)
- fc_host_supported_speeds(shost) |= FC_PORTSPEED_1GBIT;
+ lpfc_host_supported_speeds_set(shost);
fc_host_maxframe_size(shost) =
(((uint32_t) vport->fc_sparam.cmn.bbRcvSizeMsb & 0x0F) << 8) |
@@ -4758,6 +4766,8 @@ lpfc_sli4_async_sli_evt(struct lpfc_hba *phba, struct lpfc_acqe_sli *acqe_sli)
struct temp_event temp_event_data;
struct lpfc_acqe_misconfigured_event *misconfigured;
struct Scsi_Host *shost;
+ struct lpfc_vport **vports;
+ int rc, i;
evt_type = bf_get(lpfc_trailer_type, acqe_sli);
@@ -4883,6 +4893,25 @@ lpfc_sli4_async_sli_evt(struct lpfc_hba *phba, struct lpfc_acqe_sli *acqe_sli)
sprintf(message, "Unknown event status x%02x", status);
break;
}
+
+ /* Issue READ_CONFIG mbox command to refresh supported speeds */
+ rc = lpfc_sli4_read_config(phba);
+ if (rc == -EIO) {
+ phba->lmt = 0;
+ lpfc_printf_log(phba, KERN_ERR, LOG_SLI,
+ "3194 Unable to retrieve supported "
+ "speeds\n");
+ }
+ vports = lpfc_create_vport_work_array(phba);
+ if (vports != NULL) {
+ for (i = 0; i <= phba->max_vports && vports[i] != NULL;
+ i++) {
+ shost = lpfc_shost_from_vport(vports[i]);
+ lpfc_host_supported_speeds_set(shost);
+ }
+ }
+ lpfc_destroy_vport_work_array(phba, vports);
+
phba->sli4_hba.lnk_info.optic_state = status;
lpfc_printf_log(phba, KERN_ERR, LOG_SLI,
"3176 Port Name %c %s\n", port_name, message);
OpenPOWER on IntegriCloud