diff options
author | Marcin Tomczak <marcin.tomczak@intel.com> | 2011-07-29 17:16:50 -0700 |
---|---|---|
committer | James Bottomley <JBottomley@Parallels.com> | 2011-08-23 19:52:14 -0700 |
commit | 985af6f70dbb8a33b3af8a7c7df508d924650e37 (patch) | |
tree | 7607fbd7e2162b5e0e16ab57720cea682fa0b9d1 /drivers/scsi/isci/phy.c | |
parent | ee33e2b771f9e9e4aaba2bb2ace7b727fe451a8b (diff) | |
download | blackbird-op-linux-985af6f70dbb8a33b3af8a7c7df508d924650e37.tar.gz blackbird-op-linux-985af6f70dbb8a33b3af8a7c7df508d924650e37.zip |
[SCSI] isci: change sas phy timeouts from 54us to 59us
Need the following workaround in the driver for interoperability with
the older Intel SSD drives and any other SATA drive that may exhibit the
same behavior. This is a corner case where SCU speed is limited to
either 3G or 1.5G and the drive has a period of DC idle when it switches
speed during SATA speed negotiation. Workaround :change PHYTOV[31:24]
from 0x36 to 0x3B.
Signed-off-by: Marcin Tomczak <marcin.tomczak@intel.com>
Signed-off-by: Dan Williams <dan.j.williams@intel.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Diffstat (limited to 'drivers/scsi/isci/phy.c')
-rw-r--r-- | drivers/scsi/isci/phy.c | 13 |
1 files changed, 13 insertions, 0 deletions
diff --git a/drivers/scsi/isci/phy.c b/drivers/scsi/isci/phy.c index 79313a7a2356..430fc8ff014a 100644 --- a/drivers/scsi/isci/phy.c +++ b/drivers/scsi/isci/phy.c @@ -104,6 +104,7 @@ sci_phy_link_layer_initialization(struct isci_phy *iphy, u32 parity_count = 0; u32 llctl, link_rate; u32 clksm_value = 0; + u32 sp_timeouts = 0; iphy->link_layer_registers = reg; @@ -211,6 +212,18 @@ sci_phy_link_layer_initialization(struct isci_phy *iphy, llctl |= SCU_SAS_LLCTL_GEN_VAL(MAX_LINK_RATE, link_rate); writel(llctl, &iphy->link_layer_registers->link_layer_control); + sp_timeouts = readl(&iphy->link_layer_registers->sas_phy_timeouts); + + /* Clear the default 0x36 (54us) RATE_CHANGE timeout value. */ + sp_timeouts &= ~SCU_SAS_PHYTOV_GEN_VAL(RATE_CHANGE, 0xFF); + + /* Set RATE_CHANGE timeout value to 0x3B (59us). This ensures SCU can + * lock with 3Gb drive when SCU max rate is set to 1.5Gb. + */ + sp_timeouts |= SCU_SAS_PHYTOV_GEN_VAL(RATE_CHANGE, 0x3B); + + writel(sp_timeouts, &iphy->link_layer_registers->sas_phy_timeouts); + if (is_a2(ihost->pdev)) { /* Program the max ARB time for the PHY to 700us so we inter-operate with * the PMC expander which shuts down PHYs if the expander PHY generates too |