summaryrefslogtreecommitdiffstats
path: root/drivers/scsi/ibmvscsi
diff options
context:
space:
mode:
authorBrian King <brking@linux.vnet.ibm.com>2010-04-20 14:21:33 -0500
committerJames Bottomley <James.Bottomley@suse.de>2010-05-02 11:03:03 -0400
commitf5832fa2f8dc39adcf3ae348d2d6383163235e79 (patch)
tree1fea25c52248b213dd44d2ad693959ff29d56495 /drivers/scsi/ibmvscsi
parent859e816704b4139d15b1ec6a3505f12faef5333a (diff)
downloadblackbird-op-linux-f5832fa2f8dc39adcf3ae348d2d6383163235e79.tar.gz
blackbird-op-linux-f5832fa2f8dc39adcf3ae348d2d6383163235e79.zip
[SCSI] ibmvfc: Fix command completion handling
Commands which are completed by the VIOS are placed on a CRQ in kernel memory for the ibmvfc driver to process. Each CRQ entry is 16 bytes. The ibmvfc driver reads the first 8 bytes to check if the entry is valid, then reads the next 8 bytes to get the handle, which is a pointer the completed command. This fixes an issue seen on Power 7 where the processor reordered the loads from memory, resulting in processing command completion with a stale handle. This could result in command timeouts, and also early completion of commands. Signed-off-by: Brian King <brking@linux.vnet.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Diffstat (limited to 'drivers/scsi/ibmvscsi')
-rw-r--r--drivers/scsi/ibmvscsi/ibmvfc.c6
1 files changed, 6 insertions, 0 deletions
diff --git a/drivers/scsi/ibmvscsi/ibmvfc.c b/drivers/scsi/ibmvscsi/ibmvfc.c
index c2eea711a5ce..9372169374e2 100644
--- a/drivers/scsi/ibmvscsi/ibmvfc.c
+++ b/drivers/scsi/ibmvscsi/ibmvfc.c
@@ -3013,6 +3013,7 @@ static struct ibmvfc_async_crq *ibmvfc_next_async_crq(struct ibmvfc_host *vhost)
if (crq->valid & 0x80) {
if (++async_crq->cur == async_crq->size)
async_crq->cur = 0;
+ rmb();
} else
crq = NULL;
@@ -3035,6 +3036,7 @@ static struct ibmvfc_crq *ibmvfc_next_crq(struct ibmvfc_host *vhost)
if (crq->valid & 0x80) {
if (++queue->cur == queue->size)
queue->cur = 0;
+ rmb();
} else
crq = NULL;
@@ -3083,12 +3085,14 @@ static void ibmvfc_tasklet(void *data)
while ((async = ibmvfc_next_async_crq(vhost)) != NULL) {
ibmvfc_handle_async(async, vhost);
async->valid = 0;
+ wmb();
}
/* Pull all the valid messages off the CRQ */
while ((crq = ibmvfc_next_crq(vhost)) != NULL) {
ibmvfc_handle_crq(crq, vhost);
crq->valid = 0;
+ wmb();
}
vio_enable_interrupts(vdev);
@@ -3096,10 +3100,12 @@ static void ibmvfc_tasklet(void *data)
vio_disable_interrupts(vdev);
ibmvfc_handle_async(async, vhost);
async->valid = 0;
+ wmb();
} else if ((crq = ibmvfc_next_crq(vhost)) != NULL) {
vio_disable_interrupts(vdev);
ibmvfc_handle_crq(crq, vhost);
crq->valid = 0;
+ wmb();
} else
done = 1;
}
OpenPOWER on IntegriCloud