diff options
author | Yaniv Rosner <yanivr@broadcom.com> | 2012-01-17 02:33:27 +0000 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2012-01-17 10:44:43 -0500 |
commit | 75318327802235ecd7e90b0760cceb994bf975ca (patch) | |
tree | 0d57527bc7f139656ea95ff25c4e05fe7340098f /drivers/net/ethernet | |
parent | 127302bb42257eef5d357722d670c4ac53327088 (diff) | |
download | blackbird-op-linux-75318327802235ecd7e90b0760cceb994bf975ca.tar.gz blackbird-op-linux-75318327802235ecd7e90b0760cceb994bf975ca.zip |
bnx2x: Remove 100Mb force speed for BCM84833
Remove unsupported speed of 100Mb force for BCM84833 due to hardware
limitation.
Signed-off-by: Yaniv Rosner <yanivr@broadcom.com>
Signed-off-by: Eilon Greenstein <eilong@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/ethernet')
-rw-r--r-- | drivers/net/ethernet/broadcom/bnx2x/bnx2x_ethtool.c | 7 | ||||
-rw-r--r-- | drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c | 20 |
2 files changed, 21 insertions, 6 deletions
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_ethtool.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_ethtool.c index a688b9d975a2..f99c6e312a5d 100644 --- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_ethtool.c +++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_ethtool.c @@ -365,13 +365,18 @@ static int bnx2x_set_settings(struct net_device *dev, struct ethtool_cmd *cmd) DP(NETIF_MSG_LINK, "cfg_idx = %x\n", cfg_idx); if (cmd->autoneg == AUTONEG_ENABLE) { + u32 an_supported_speed = bp->port.supported[cfg_idx]; + if (bp->link_params.phy[EXT_PHY1].type == + PORT_HW_CFG_XGXS_EXT_PHY_TYPE_BCM84833) + an_supported_speed |= (SUPPORTED_100baseT_Half | + SUPPORTED_100baseT_Full); if (!(bp->port.supported[cfg_idx] & SUPPORTED_Autoneg)) { DP(NETIF_MSG_LINK, "Autoneg not supported\n"); return -EINVAL; } /* advertise the requested speed and duplex if supported */ - if (cmd->advertising & ~(bp->port.supported[cfg_idx])) { + if (cmd->advertising & ~an_supported_speed) { DP(NETIF_MSG_LINK, "Advertisement parameters " "are not supported\n"); return -EINVAL; diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c index cc806378464d..1d1a8093e62e 100644 --- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c +++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c @@ -9454,13 +9454,10 @@ static int bnx2x_848xx_cmn_config_init(struct bnx2x_phy *phy, an_1000_val); /* set 100 speed advertisement */ - if (((phy->req_line_speed == SPEED_AUTO_NEG) && + if ((phy->req_line_speed == SPEED_AUTO_NEG) && (phy->speed_cap_mask & (PORT_HW_CFG_SPEED_CAPABILITY_D0_100M_FULL | - PORT_HW_CFG_SPEED_CAPABILITY_D0_100M_HALF)) && - (phy->supported & - (SUPPORTED_100baseT_Half | - SUPPORTED_100baseT_Full)))) { + PORT_HW_CFG_SPEED_CAPABILITY_D0_100M_HALF))) { an_10_100_val |= (1<<7); /* Enable autoneg and restart autoneg for legacy speeds */ autoneg_val |= (1<<9 | 1<<12); @@ -11528,6 +11525,19 @@ static int bnx2x_populate_ext_phy(struct bnx2x *bp, } phy->mdio_ctrl = bnx2x_get_emac_base(bp, mdc_mdio_access, port); + if ((phy->type == PORT_HW_CFG_XGXS_EXT_PHY_TYPE_BCM84833) && + (phy->ver_addr)) { + /* + * Remove 100Mb link supported for BCM84833 when phy fw + * version lower than or equal to 1.39 + */ + u32 raw_ver = REG_RD(bp, phy->ver_addr); + if (((raw_ver & 0x7F) <= 39) && + (((raw_ver & 0xF80) >> 7) <= 1)) + phy->supported &= ~(SUPPORTED_100baseT_Half | + SUPPORTED_100baseT_Full); + } + /* * In case mdc/mdio_access of the external phy is different than the * mdc/mdio access of the XGXS, a HW lock must be taken in each access |