summaryrefslogtreecommitdiffstats
path: root/drivers/md
diff options
context:
space:
mode:
authorNeilBrown <neilb@suse.de>2012-05-31 15:39:11 +1000
committerNeilBrown <neilb@suse.de>2012-05-31 15:56:30 +1000
commitaba336bd1d46d6b0404b06f6915ed76150739057 (patch)
tree6517e35ba3f6df77276d9c4e81d8ec726228aacd /drivers/md
parent2aa4ee2a8805ec0260dde971e9e6699917c868a7 (diff)
downloadblackbird-op-linux-aba336bd1d46d6b0404b06f6915ed76150739057.tar.gz
blackbird-op-linux-aba336bd1d46d6b0404b06f6915ed76150739057.zip
md: raid1/raid10: fix problem with merge_bvec_fn
The new merge_bvec_fn which calls the corresponding function in subsidiary devices requires that mddev->merge_check_needed be set if any child has a merge_bvec_fn. However were were only setting that when a device was hot-added, not when a device was present from the start. This bug was introduced in 3.4 so patch is suitable for 3.4.y kernels. However that are conflicts in raid10.c so a separate patch will be needed for 3.4.y. Cc: stable@vger.kernel.org Reported-by: Sebastian Riemer <sebastian.riemer@profitbricks.com> Signed-off-by: NeilBrown <neilb@suse.de>
Diffstat (limited to 'drivers/md')
-rw-r--r--drivers/md/raid1.c4
-rw-r--r--drivers/md/raid10.c4
2 files changed, 8 insertions, 0 deletions
diff --git a/drivers/md/raid1.c b/drivers/md/raid1.c
index 835de7168cd3..a9c7981ddd24 100644
--- a/drivers/md/raid1.c
+++ b/drivers/md/raid1.c
@@ -2550,6 +2550,7 @@ static struct r1conf *setup_conf(struct mddev *mddev)
err = -EINVAL;
spin_lock_init(&conf->device_lock);
rdev_for_each(rdev, mddev) {
+ struct request_queue *q;
int disk_idx = rdev->raid_disk;
if (disk_idx >= mddev->raid_disks
|| disk_idx < 0)
@@ -2562,6 +2563,9 @@ static struct r1conf *setup_conf(struct mddev *mddev)
if (disk->rdev)
goto abort;
disk->rdev = rdev;
+ q = bdev_get_queue(rdev->bdev);
+ if (q->merge_bvec_fn)
+ mddev->merge_check_needed = 1;
disk->head_position = 0;
}
diff --git a/drivers/md/raid10.c b/drivers/md/raid10.c
index 987db37cb875..99ae6068e456 100644
--- a/drivers/md/raid10.c
+++ b/drivers/md/raid10.c
@@ -3475,6 +3475,7 @@ static int run(struct mddev *mddev)
rdev_for_each(rdev, mddev) {
long long diff;
+ struct request_queue *q;
disk_idx = rdev->raid_disk;
if (disk_idx < 0)
@@ -3493,6 +3494,9 @@ static int run(struct mddev *mddev)
goto out_free_conf;
disk->rdev = rdev;
}
+ q = bdev_get_queue(rdev->bdev);
+ if (q->merge_bvec_fn)
+ mddev->merge_check_needed = 1;
diff = (rdev->new_data_offset - rdev->data_offset);
if (!mddev->reshape_backwards)
diff = -diff;