summaryrefslogtreecommitdiffstats
path: root/drivers/md
diff options
context:
space:
mode:
authorKent Overstreet <kmo@daterainc.com>2013-07-10 18:44:40 -0700
committerKent Overstreet <kmo@daterainc.com>2013-07-12 00:22:46 -0700
commit54d12f2b4fd0f218590d1490b41a18d0e2328a9a (patch)
tree2a7eb0a2749191087c120ae1eda0e73cabf4af34 /drivers/md
parentd2a65ce2ac224413b291307201c5dafb03aa90d7 (diff)
downloadblackbird-op-linux-54d12f2b4fd0f218590d1490b41a18d0e2328a9a.tar.gz
blackbird-op-linux-54d12f2b4fd0f218590d1490b41a18d0e2328a9a.zip
bcache: Advertise that flushes are supported
Whoops - bcache's flush/FUA was mostly correct, but flushes get filtered out unless we say we support them... Signed-off-by: Kent Overstreet <kmo@daterainc.com> Cc: linux-stable <stable@vger.kernel.org> # >= v3.10
Diffstat (limited to 'drivers/md')
-rw-r--r--drivers/md/bcache/request.c8
-rw-r--r--drivers/md/bcache/super.c2
2 files changed, 9 insertions, 1 deletions
diff --git a/drivers/md/bcache/request.c b/drivers/md/bcache/request.c
index b6e74d3c8faf..786a1a4f74d8 100644
--- a/drivers/md/bcache/request.c
+++ b/drivers/md/bcache/request.c
@@ -488,6 +488,12 @@ static void bch_insert_data_loop(struct closure *cl)
bch_queue_gc(op->c);
}
+ /*
+ * Journal writes are marked REQ_FLUSH; if the original write was a
+ * flush, it'll wait on the journal write.
+ */
+ bio->bi_rw &= ~(REQ_FLUSH|REQ_FUA);
+
do {
unsigned i;
struct bkey *k;
@@ -710,7 +716,7 @@ static struct search *search_alloc(struct bio *bio, struct bcache_device *d)
s->task = current;
s->orig_bio = bio;
s->write = (bio->bi_rw & REQ_WRITE) != 0;
- s->op.flush_journal = (bio->bi_rw & REQ_FLUSH) != 0;
+ s->op.flush_journal = (bio->bi_rw & (REQ_FLUSH|REQ_FUA)) != 0;
s->op.skip = (bio->bi_rw & REQ_DISCARD) != 0;
s->recoverable = 1;
s->start_time = jiffies;
diff --git a/drivers/md/bcache/super.c b/drivers/md/bcache/super.c
index cff2d182dfb0..728fdc673f31 100644
--- a/drivers/md/bcache/super.c
+++ b/drivers/md/bcache/super.c
@@ -806,6 +806,8 @@ static int bcache_device_init(struct bcache_device *d, unsigned block_size,
set_bit(QUEUE_FLAG_NONROT, &d->disk->queue->queue_flags);
set_bit(QUEUE_FLAG_DISCARD, &d->disk->queue->queue_flags);
+ blk_queue_flush(q, REQ_FLUSH|REQ_FUA);
+
return 0;
}
OpenPOWER on IntegriCloud