diff options
author | Zhang Rui <rui.zhang@intel.com> | 2017-07-05 14:51:32 +0800 |
---|---|---|
committer | Zhang Rui <rui.zhang@intel.com> | 2017-07-05 14:51:32 +0800 |
commit | 467aebee872af7f5e703809e19a66de633a1aa2c (patch) | |
tree | 21a80e16c5e7a3c1d34c60fb6f6274eb9e6c1347 /drivers/cpufreq | |
parent | c0bc126f97fb929b3ae02c1c62322645d70eb408 (diff) | |
parent | 1fe3854a83b580727c9464b37b62ba77ead1d6f6 (diff) | |
download | blackbird-op-linux-467aebee872af7f5e703809e19a66de633a1aa2c.tar.gz blackbird-op-linux-467aebee872af7f5e703809e19a66de633a1aa2c.zip |
Merge branch 'linus' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal into thermal-soc
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r-- | drivers/cpufreq/arm_big_little.c | 2 | ||||
-rw-r--r-- | drivers/cpufreq/cpufreq-dt.c | 2 | ||||
-rw-r--r-- | drivers/cpufreq/cpufreq_stats.c | 13 | ||||
-rw-r--r-- | drivers/cpufreq/dbx500-cpufreq.c | 2 | ||||
-rw-r--r-- | drivers/cpufreq/mt8173-cpufreq.c | 4 | ||||
-rw-r--r-- | drivers/cpufreq/qoriq-cpufreq.c | 3 |
6 files changed, 9 insertions, 17 deletions
diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c index 418042201e6d..ea6d62547b10 100644 --- a/drivers/cpufreq/arm_big_little.c +++ b/drivers/cpufreq/arm_big_little.c @@ -540,7 +540,7 @@ static void bL_cpufreq_ready(struct cpufreq_policy *policy) &power_coefficient); cdev[cur_cluster] = of_cpufreq_power_cooling_register(np, - policy->related_cpus, power_coefficient, NULL); + policy, power_coefficient, NULL); if (IS_ERR(cdev[cur_cluster])) { dev_err(cpu_dev, "running cpufreq without cooling device: %ld\n", diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c index c943787d761e..fef3c2160691 100644 --- a/drivers/cpufreq/cpufreq-dt.c +++ b/drivers/cpufreq/cpufreq-dt.c @@ -326,7 +326,7 @@ static void cpufreq_ready(struct cpufreq_policy *policy) &power_coefficient); priv->cdev = of_cpufreq_power_cooling_register(np, - policy->related_cpus, power_coefficient, NULL); + policy, power_coefficient, NULL); if (IS_ERR(priv->cdev)) { dev_err(priv->cpu_dev, "running cpufreq without cooling device: %ld\n", diff --git a/drivers/cpufreq/cpufreq_stats.c b/drivers/cpufreq/cpufreq_stats.c index f570ead62454..9c3d319dc129 100644 --- a/drivers/cpufreq/cpufreq_stats.c +++ b/drivers/cpufreq/cpufreq_stats.c @@ -170,11 +170,10 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy) unsigned int i = 0, count = 0, ret = -ENOMEM; struct cpufreq_stats *stats; unsigned int alloc_size; - struct cpufreq_frequency_table *pos, *table; + struct cpufreq_frequency_table *pos; - /* We need cpufreq table for creating stats table */ - table = policy->freq_table; - if (unlikely(!table)) + count = cpufreq_table_count_valid_entries(policy); + if (!count) return; /* stats already initialized */ @@ -185,10 +184,6 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy) if (!stats) return; - /* Find total allocation size */ - cpufreq_for_each_valid_entry(pos, table) - count++; - alloc_size = count * sizeof(int) + count * sizeof(u64); alloc_size += count * count * sizeof(int); @@ -205,7 +200,7 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy) stats->max_state = count; /* Find valid-unique entries */ - cpufreq_for_each_valid_entry(pos, table) + cpufreq_for_each_valid_entry(pos, policy->freq_table) if (freq_table_get_index(stats, pos->frequency) == -1) stats->freq_table[i++] = pos->frequency; diff --git a/drivers/cpufreq/dbx500-cpufreq.c b/drivers/cpufreq/dbx500-cpufreq.c index 3575b82210ba..4ee0431579c1 100644 --- a/drivers/cpufreq/dbx500-cpufreq.c +++ b/drivers/cpufreq/dbx500-cpufreq.c @@ -43,7 +43,7 @@ static int dbx500_cpufreq_exit(struct cpufreq_policy *policy) static void dbx500_cpufreq_ready(struct cpufreq_policy *policy) { - cdev = cpufreq_cooling_register(policy->cpus); + cdev = cpufreq_cooling_register(policy); if (IS_ERR(cdev)) pr_err("Failed to register cooling device %ld\n", PTR_ERR(cdev)); else diff --git a/drivers/cpufreq/mt8173-cpufreq.c b/drivers/cpufreq/mt8173-cpufreq.c index fd1886faf33a..f9f00fb4bc3a 100644 --- a/drivers/cpufreq/mt8173-cpufreq.c +++ b/drivers/cpufreq/mt8173-cpufreq.c @@ -320,9 +320,7 @@ static void mtk_cpufreq_ready(struct cpufreq_policy *policy) of_property_read_u32(np, DYNAMIC_POWER, &capacitance); info->cdev = of_cpufreq_power_cooling_register(np, - policy->related_cpus, - capacitance, - NULL); + policy, capacitance, NULL); if (IS_ERR(info->cdev)) { dev_err(info->cpu_dev, diff --git a/drivers/cpufreq/qoriq-cpufreq.c b/drivers/cpufreq/qoriq-cpufreq.c index e2ea433a5f9c..4ada55b8856e 100644 --- a/drivers/cpufreq/qoriq-cpufreq.c +++ b/drivers/cpufreq/qoriq-cpufreq.c @@ -278,8 +278,7 @@ static void qoriq_cpufreq_ready(struct cpufreq_policy *policy) struct device_node *np = of_get_cpu_node(policy->cpu, NULL); if (of_find_property(np, "#cooling-cells", NULL)) { - cpud->cdev = of_cpufreq_cooling_register(np, - policy->related_cpus); + cpud->cdev = of_cpufreq_cooling_register(np, policy); if (IS_ERR(cpud->cdev) && PTR_ERR(cpud->cdev) != -ENOSYS) { pr_err("cpu%d is not running as cooling device: %ld\n", |