summaryrefslogtreecommitdiffstats
path: root/drivers/cpufreq
diff options
context:
space:
mode:
authorZhang Rui <rui.zhang@intel.com>2017-07-05 14:51:32 +0800
committerZhang Rui <rui.zhang@intel.com>2017-07-05 14:51:32 +0800
commit467aebee872af7f5e703809e19a66de633a1aa2c (patch)
tree21a80e16c5e7a3c1d34c60fb6f6274eb9e6c1347 /drivers/cpufreq
parentc0bc126f97fb929b3ae02c1c62322645d70eb408 (diff)
parent1fe3854a83b580727c9464b37b62ba77ead1d6f6 (diff)
downloadblackbird-op-linux-467aebee872af7f5e703809e19a66de633a1aa2c.tar.gz
blackbird-op-linux-467aebee872af7f5e703809e19a66de633a1aa2c.zip
Merge branch 'linus' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal into thermal-soc
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r--drivers/cpufreq/arm_big_little.c2
-rw-r--r--drivers/cpufreq/cpufreq-dt.c2
-rw-r--r--drivers/cpufreq/cpufreq_stats.c13
-rw-r--r--drivers/cpufreq/dbx500-cpufreq.c2
-rw-r--r--drivers/cpufreq/mt8173-cpufreq.c4
-rw-r--r--drivers/cpufreq/qoriq-cpufreq.c3
6 files changed, 9 insertions, 17 deletions
diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c
index 418042201e6d..ea6d62547b10 100644
--- a/drivers/cpufreq/arm_big_little.c
+++ b/drivers/cpufreq/arm_big_little.c
@@ -540,7 +540,7 @@ static void bL_cpufreq_ready(struct cpufreq_policy *policy)
&power_coefficient);
cdev[cur_cluster] = of_cpufreq_power_cooling_register(np,
- policy->related_cpus, power_coefficient, NULL);
+ policy, power_coefficient, NULL);
if (IS_ERR(cdev[cur_cluster])) {
dev_err(cpu_dev,
"running cpufreq without cooling device: %ld\n",
diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c
index c943787d761e..fef3c2160691 100644
--- a/drivers/cpufreq/cpufreq-dt.c
+++ b/drivers/cpufreq/cpufreq-dt.c
@@ -326,7 +326,7 @@ static void cpufreq_ready(struct cpufreq_policy *policy)
&power_coefficient);
priv->cdev = of_cpufreq_power_cooling_register(np,
- policy->related_cpus, power_coefficient, NULL);
+ policy, power_coefficient, NULL);
if (IS_ERR(priv->cdev)) {
dev_err(priv->cpu_dev,
"running cpufreq without cooling device: %ld\n",
diff --git a/drivers/cpufreq/cpufreq_stats.c b/drivers/cpufreq/cpufreq_stats.c
index f570ead62454..9c3d319dc129 100644
--- a/drivers/cpufreq/cpufreq_stats.c
+++ b/drivers/cpufreq/cpufreq_stats.c
@@ -170,11 +170,10 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy)
unsigned int i = 0, count = 0, ret = -ENOMEM;
struct cpufreq_stats *stats;
unsigned int alloc_size;
- struct cpufreq_frequency_table *pos, *table;
+ struct cpufreq_frequency_table *pos;
- /* We need cpufreq table for creating stats table */
- table = policy->freq_table;
- if (unlikely(!table))
+ count = cpufreq_table_count_valid_entries(policy);
+ if (!count)
return;
/* stats already initialized */
@@ -185,10 +184,6 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy)
if (!stats)
return;
- /* Find total allocation size */
- cpufreq_for_each_valid_entry(pos, table)
- count++;
-
alloc_size = count * sizeof(int) + count * sizeof(u64);
alloc_size += count * count * sizeof(int);
@@ -205,7 +200,7 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy)
stats->max_state = count;
/* Find valid-unique entries */
- cpufreq_for_each_valid_entry(pos, table)
+ cpufreq_for_each_valid_entry(pos, policy->freq_table)
if (freq_table_get_index(stats, pos->frequency) == -1)
stats->freq_table[i++] = pos->frequency;
diff --git a/drivers/cpufreq/dbx500-cpufreq.c b/drivers/cpufreq/dbx500-cpufreq.c
index 3575b82210ba..4ee0431579c1 100644
--- a/drivers/cpufreq/dbx500-cpufreq.c
+++ b/drivers/cpufreq/dbx500-cpufreq.c
@@ -43,7 +43,7 @@ static int dbx500_cpufreq_exit(struct cpufreq_policy *policy)
static void dbx500_cpufreq_ready(struct cpufreq_policy *policy)
{
- cdev = cpufreq_cooling_register(policy->cpus);
+ cdev = cpufreq_cooling_register(policy);
if (IS_ERR(cdev))
pr_err("Failed to register cooling device %ld\n", PTR_ERR(cdev));
else
diff --git a/drivers/cpufreq/mt8173-cpufreq.c b/drivers/cpufreq/mt8173-cpufreq.c
index fd1886faf33a..f9f00fb4bc3a 100644
--- a/drivers/cpufreq/mt8173-cpufreq.c
+++ b/drivers/cpufreq/mt8173-cpufreq.c
@@ -320,9 +320,7 @@ static void mtk_cpufreq_ready(struct cpufreq_policy *policy)
of_property_read_u32(np, DYNAMIC_POWER, &capacitance);
info->cdev = of_cpufreq_power_cooling_register(np,
- policy->related_cpus,
- capacitance,
- NULL);
+ policy, capacitance, NULL);
if (IS_ERR(info->cdev)) {
dev_err(info->cpu_dev,
diff --git a/drivers/cpufreq/qoriq-cpufreq.c b/drivers/cpufreq/qoriq-cpufreq.c
index e2ea433a5f9c..4ada55b8856e 100644
--- a/drivers/cpufreq/qoriq-cpufreq.c
+++ b/drivers/cpufreq/qoriq-cpufreq.c
@@ -278,8 +278,7 @@ static void qoriq_cpufreq_ready(struct cpufreq_policy *policy)
struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
if (of_find_property(np, "#cooling-cells", NULL)) {
- cpud->cdev = of_cpufreq_cooling_register(np,
- policy->related_cpus);
+ cpud->cdev = of_cpufreq_cooling_register(np, policy);
if (IS_ERR(cpud->cdev) && PTR_ERR(cpud->cdev) != -ENOSYS) {
pr_err("cpu%d is not running as cooling device: %ld\n",
OpenPOWER on IntegriCloud