summaryrefslogtreecommitdiffstats
path: root/drivers/clk
diff options
context:
space:
mode:
authorStephen Warren <swarren@nvidia.com>2019-10-03 14:50:30 -0600
committerThierry Reding <treding@nvidia.com>2020-01-08 12:55:19 +0100
commitbf83b96f87ae2abb1e535306ea53608e8de5dfbb (patch)
tree1af88da15b2145022e184d3e5e2d2cf22075d09e /drivers/clk
parente42617b825f8073569da76dc4510bfa019b1c35a (diff)
downloadblackbird-op-linux-bf83b96f87ae2abb1e535306ea53608e8de5dfbb.tar.gz
blackbird-op-linux-bf83b96f87ae2abb1e535306ea53608e8de5dfbb.zip
clk: tegra: Mark fuse clock as critical
For a little over a year, U-Boot on Tegra124 has configured the flow controller to perform automatic RAM re-repair on off->on power transitions of the CPU rail[1]. This is mandatory for correct operation of Tegra124. However, RAM re-repair relies on certain clocks, which the kernel must enable and leave running. The fuse clock is one of those clocks. Mark this clock as critical so that LP1 power mode (system suspend) operates correctly. [1] 3cc7942a4ae5 ARM: tegra: implement RAM repair Reported-by: Jonathan Hunter <jonathanh@nvidia.com> Cc: stable@vger.kernel.org Signed-off-by: Stephen Warren <swarren@nvidia.com> Signed-off-by: Thierry Reding <treding@nvidia.com>
Diffstat (limited to 'drivers/clk')
-rw-r--r--drivers/clk/tegra/clk-tegra-periph.c6
1 files changed, 5 insertions, 1 deletions
diff --git a/drivers/clk/tegra/clk-tegra-periph.c b/drivers/clk/tegra/clk-tegra-periph.c
index 0d07c0ba49b6..2b2a3b81c16b 100644
--- a/drivers/clk/tegra/clk-tegra-periph.c
+++ b/drivers/clk/tegra/clk-tegra-periph.c
@@ -777,7 +777,11 @@ static struct tegra_periph_init_data gate_clks[] = {
GATE("ahbdma", "hclk", 33, 0, tegra_clk_ahbdma, 0),
GATE("apbdma", "pclk", 34, 0, tegra_clk_apbdma, 0),
GATE("kbc", "clk_32k", 36, TEGRA_PERIPH_ON_APB | TEGRA_PERIPH_NO_RESET, tegra_clk_kbc, 0),
- GATE("fuse", "clk_m", 39, TEGRA_PERIPH_ON_APB, tegra_clk_fuse, 0),
+ /*
+ * Critical for RAM re-repair operation, which must occur on resume
+ * from LP1 system suspend and as part of CCPLEX cluster switching.
+ */
+ GATE("fuse", "clk_m", 39, TEGRA_PERIPH_ON_APB, tegra_clk_fuse, CLK_IS_CRITICAL),
GATE("fuse_burn", "clk_m", 39, TEGRA_PERIPH_ON_APB, tegra_clk_fuse_burn, 0),
GATE("kfuse", "clk_m", 40, TEGRA_PERIPH_ON_APB, tegra_clk_kfuse, 0),
GATE("apbif", "clk_m", 107, TEGRA_PERIPH_ON_APB, tegra_clk_apbif, 0),
OpenPOWER on IntegriCloud