diff options
author | Tobin C. Harding <me@tobin.cc> | 2018-07-12 07:42:50 +1000 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2018-07-16 11:23:54 -0700 |
commit | 2880984970ddf3f3a4600f1725621792352b8627 (patch) | |
tree | 6d83cab978d64b1de7851ea48ecba9bf8b03d742 /Documentation/networking | |
parent | d95768d3cccd0bfb258f04e0fa21768332b153a0 (diff) | |
download | blackbird-op-linux-2880984970ddf3f3a4600f1725621792352b8627.tar.gz blackbird-op-linux-2880984970ddf3f3a4600f1725621792352b8627.zip |
docs: networking: Fix failover build warnings
Currently building the net_failover docs causes a bunch of warnings to
be emitted. These warnings are all related to indentation and correctly
highlight missing '::' (for code sections). It looks, from other rst
files in Documentation, that the first column should be indented 2
spaces.
Add '::' before code snippets and indent all snippets uniformly starting
with 2 spaces.
Cc: Jonathan Corbet <corbet@lwn.net>
Signed-off-by: Tobin C. Harding <me@tobin.cc>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'Documentation/networking')
-rw-r--r-- | Documentation/networking/net_failover.rst | 111 |
1 files changed, 57 insertions, 54 deletions
diff --git a/Documentation/networking/net_failover.rst b/Documentation/networking/net_failover.rst index 70ca2f5800c4..06c97dcb57ca 100644 --- a/Documentation/networking/net_failover.rst +++ b/Documentation/networking/net_failover.rst @@ -36,37 +36,39 @@ feature on the virtio-net interface and assign the same MAC address to both virtio-net and VF interfaces. Here is an example XML snippet that shows such configuration. - - <interface type='network'> - <mac address='52:54:00:00:12:53'/> - <source network='enp66s0f0_br'/> - <target dev='tap01'/> - <model type='virtio'/> - <driver name='vhost' queues='4'/> - <link state='down'/> - <address type='pci' domain='0x0000' bus='0x00' slot='0x0a' function='0x0'/> - </interface> - <interface type='hostdev' managed='yes'> - <mac address='52:54:00:00:12:53'/> - <source> - <address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/> - </source> - <address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/> - </interface> +:: + + <interface type='network'> + <mac address='52:54:00:00:12:53'/> + <source network='enp66s0f0_br'/> + <target dev='tap01'/> + <model type='virtio'/> + <driver name='vhost' queues='4'/> + <link state='down'/> + <address type='pci' domain='0x0000' bus='0x00' slot='0x0a' function='0x0'/> + </interface> + <interface type='hostdev' managed='yes'> + <mac address='52:54:00:00:12:53'/> + <source> + <address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/> + </source> + <address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/> + </interface> Booting a VM with the above configuration will result in the following 3 netdevs created in the VM. - -4: ens10: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000 - link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff - inet 192.168.12.53/24 brd 192.168.12.255 scope global dynamic ens10 - valid_lft 42482sec preferred_lft 42482sec - inet6 fe80::97d8:db2:8c10:b6d6/64 scope link - valid_lft forever preferred_lft forever -5: ens10nsby: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc fq_codel master ens10 state UP group default qlen 1000 - link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff -7: ens11: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master ens10 state UP group default qlen 1000 - link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff +:: + + 4: ens10: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000 + link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff + inet 192.168.12.53/24 brd 192.168.12.255 scope global dynamic ens10 + valid_lft 42482sec preferred_lft 42482sec + inet6 fe80::97d8:db2:8c10:b6d6/64 scope link + valid_lft forever preferred_lft forever + 5: ens10nsby: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc fq_codel master ens10 state UP group default qlen 1000 + link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff + 7: ens11: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master ens10 state UP group default qlen 1000 + link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff ens10 is the 'failover' master netdev, ens10nsby and ens11 are the slave 'standby' and 'primary' netdevs respectively. @@ -80,37 +82,38 @@ the paravirtual datapath when the VF is unplugged. Here is a sample script that shows the steps to initiate live migration on the source hypervisor. +:: -# cat vf_xml -<interface type='hostdev' managed='yes'> - <mac address='52:54:00:00:12:53'/> - <source> - <address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/> - </source> - <address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/> -</interface> + # cat vf_xml + <interface type='hostdev' managed='yes'> + <mac address='52:54:00:00:12:53'/> + <source> + <address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/> + </source> + <address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/> + </interface> -# Source Hypervisor -#!/bin/bash + # Source Hypervisor + #!/bin/bash -DOMAIN=fedora27-tap01 -PF=enp66s0f0 -VF_NUM=5 -TAP_IF=tap01 -VF_XML= + DOMAIN=fedora27-tap01 + PF=enp66s0f0 + VF_NUM=5 + TAP_IF=tap01 + VF_XML= -MAC=52:54:00:00:12:53 -ZERO_MAC=00:00:00:00:00:00 + MAC=52:54:00:00:12:53 + ZERO_MAC=00:00:00:00:00:00 -virsh domif-setlink $DOMAIN $TAP_IF up -bridge fdb del $MAC dev $PF master -virsh detach-device $DOMAIN $VF_XML -ip link set $PF vf $VF_NUM mac $ZERO_MAC + virsh domif-setlink $DOMAIN $TAP_IF up + bridge fdb del $MAC dev $PF master + virsh detach-device $DOMAIN $VF_XML + ip link set $PF vf $VF_NUM mac $ZERO_MAC -virsh migrate --live $DOMAIN qemu+ssh://$REMOTE_HOST/system + virsh migrate --live $DOMAIN qemu+ssh://$REMOTE_HOST/system -# Destination Hypervisor -#!/bin/bash + # Destination Hypervisor + #!/bin/bash -virsh attach-device $DOMAIN $VF_XML -virsh domif-setlink $DOMAIN $TAP_IF down + virsh attach-device $DOMAIN $VF_XML + virsh domif-setlink $DOMAIN $TAP_IF down |