summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon
diff options
context:
space:
mode:
authorMatt Ranostay <mranostay@gmail.com>2016-07-09 23:49:18 -0700
committerGuenter Roeck <linux@roeck-us.net>2016-07-16 08:40:13 -0700
commit50c22cd154e5f7d13072d98ef3e2baba3c074734 (patch)
treef5157e7ba3626a0b886260a18a79b2aecc102288 /Documentation/hwmon
parent803deccec2513379ff0873a386d955af6f43d005 (diff)
downloadblackbird-op-linux-50c22cd154e5f7d13072d98ef3e2baba3c074734.tar.gz
blackbird-op-linux-50c22cd154e5f7d13072d98ef3e2baba3c074734.zip
hwmon: (sht3x) add humidity heater element control
The enables control of the SHT31 sensors heating element that can turned on to remove excess humidity. Cc: Guenter Roeck <linux@roeck-us.net> Cc: David Frey <david.frey@sensirion.com> Signed-off-by: Matt Ranostay <mranostay@gmail.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/sht3x4
1 files changed, 4 insertions, 0 deletions
diff --git a/Documentation/hwmon/sht3x b/Documentation/hwmon/sht3x
index f5aa633ed383..b0d88184f48e 100644
--- a/Documentation/hwmon/sht3x
+++ b/Documentation/hwmon/sht3x
@@ -67,6 +67,10 @@ temp1_alarm: alarm flag is set to 1 if the temperature is outside the
configured limits. Alarm only works in periodic measure mode
humidity1_alarm: alarm flag is set to 1 if the humidity is outside the
configured limits. Alarm only works in periodic measure mode
+heater_enable: heater enable, heating element removes excess humidity from
+ sensor
+ 0: turned off
+ 1: turned on
update_interval: update interval, 0 for single shot, interval in msec
for periodic measurement. If the interval is not supported
by the sensor, the next faster interval is chosen
OpenPOWER on IntegriCloud