hwmon: (pmbus) Support for TI UCD90xxx series Sequencer and System Health Controllers
Hardware monitoring support for TI UCD90120, UCD90124, UCD9090, and UCD90910 Sequencer and System Health Controllers. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Tom Grennan <tom.grennan@ericsson.com>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/ucd9000110
1 files changed, 110 insertions, 0 deletions
diff --git a/Documentation/hwmon/ucd9000 b/Documentation/hwmon/ucd9000
new file mode 100644
index 000000000000..40ca6db50c48
--- /dev/null
+++ b/Documentation/hwmon/ucd9000
@@ -0,0 +1,110 @@
+Kernel driver ucd9000
+=====================
+
+Supported chips:
+ * TI UCD90120, UCD90124, UCD9090, and UCD90910
+ Prefixes: 'ucd90120', 'ucd90124', 'ucd9090', 'ucd90910'
+ Addresses scanned: -
+ Datasheets:
+ http://focus.ti.com/lit/ds/symlink/ucd90120.pdf
+ http://focus.ti.com/lit/ds/symlink/ucd90124.pdf
+ http://focus.ti.com/lit/ds/symlink/ucd9090.pdf
+ http://focus.ti.com/lit/ds/symlink/ucd90910.pdf
+
+Author: Guenter Roeck <guenter.roeck@ericsson.com>
+
+
+Description
+-----------
+
+From datasheets:
+
+The UCD90120 Power Supply Sequencer and System Health Monitor monitors and
+sequences up to 12 independent voltage rails. The device integrates a 12-bit
+ADC with a 2.5V internal reference for monitoring up to 13 power supply voltage,
+current, or temperature inputs.
+
+The UCD90124 is a 12-rail PMBus/I2C addressable power-supply sequencer and
+system-health monitor. The device integrates a 12-bit ADC for monitoring up to
+13 power-supply voltage, current, or temperature inputs. Twenty-six GPIO pins
+can be used for power supply enables, power-on reset signals, external
+interrupts, cascading, or other system functions. Twelve of these pins offer PWM
+functionality. Using these pins, the UCD90124 offers support for fan control,
+margining, and general-purpose PWM functions.
+
+The UCD9090 is a 10-rail PMBus/I2C addressable power-supply sequencer and
+monitor. The device integrates a 12-bit ADC for monitoring up to 10 power-supply
+voltage inputs. Twenty-three GPIO pins can be used for power supply enables,
+power-on reset signals, external interrupts, cascading, or other system
+functions. Ten of these pins offer PWM functionality. Using these pins, the
+UCD9090 offers support for margining, and general-purpose PWM functions.
+
+The UCD90910 is a ten-rail I2C / PMBus addressable power-supply sequencer and
+system-health monitor. The device integrates a 12-bit ADC for monitoring up to
+13 power-supply voltage, current, or temperature inputs.
+
+This driver is a client driver to the core PMBus driver. Please see
+Documentation/hwmon/pmbus for details on PMBus client drivers.
+
+
+Usage Notes
+-----------
+
+This driver does not auto-detect devices. You will have to instantiate the
+devices explicitly. Please see Documentation/i2c/instantiating-devices for
+details.
+
+
+Platform data support
+---------------------
+
+The driver supports standard PMBus driver platform data. Please see
+Documentation/hwmon/pmbus for details.
+
+
+Sysfs entries
+-------------
+
+The following attributes are supported. Limits are read-write; all other
+attributes are read-only.
+
+in[1-12]_label "vout[1-12]".
+in[1-12]_input Measured voltage. From READ_VOUT register.
+in[1-12]_min Minumum Voltage. From VOUT_UV_WARN_LIMIT register.
+in[1-12]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
+in[1-12]_lcrit Critical minumum Voltage. VOUT_UV_FAULT_LIMIT register.
+in[1-12]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
+in[1-12]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
+in[1-12]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
+in[1-12]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
+in[1-12]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
+
+curr[1-12]_label "iout[1-12]".
+curr[1-12]_input Measured current. From READ_IOUT register.
+curr[1-12]_max Maximum current. From IOUT_OC_WARN_LIMIT register.
+curr[1-12]_lcrit Critical minumum output current. From IOUT_UC_FAULT_LIMIT
+ register.
+curr[1-12]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
+curr[1-12]_max_alarm Current high alarm. From IOUT_OC_WARNING status.
+curr[1-12]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
+
+ For each attribute index, either voltage or current is
+ reported, but not both. If voltage or current is
+ reported depends on the chip configuration.
+
+temp[1-2]_input Measured temperatures. From READ_TEMPERATURE_1 and
+ READ_TEMPERATURE_2 registers.
+temp[1-2]_max Maximum temperature. From OT_WARN_LIMIT register.
+temp[1-2]_crit Critical high temperature. From OT_FAULT_LIMIT register.
+temp[1-2]_max_alarm Temperature high alarm.
+temp[1-2]_crit_alarm Temperature critical high alarm.
+
+fan[1-4]_input Fan RPM.
+fan[1-4]_alarm Fan alarm.
+fan[1-4]_fault Fan fault.
+
+ Fan attributes are only available on chips supporting
+ fan control (UCD90124, UCD90910). Attribute files are
+ created only for enabled fans.
+ Note that even though UCD90910 supports up to 10 fans,
+ only up to four fans are currently supported.