summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings
diff options
context:
space:
mode:
authorBoris Brezillon <boris.brezillon@free-electrons.com>2016-06-14 11:13:22 +0200
committerThierry Reding <thierry.reding@gmail.com>2016-07-25 15:34:06 +0200
commit58fd822b2e344edae6b4dbc09b19bd0c4a2f8f60 (patch)
tree3d9e96437051d333484662acdc007196a89fc300 /Documentation/devicetree/bindings
parentea398e28739e25651ede7ddf5aeb57cbcbc8ca7d (diff)
downloadblackbird-op-linux-58fd822b2e344edae6b4dbc09b19bd0c4a2f8f60.tar.gz
blackbird-op-linux-58fd822b2e344edae6b4dbc09b19bd0c4a2f8f60.zip
regulator: pwm: Document pwm-dutycycle-unit and pwm-dutycycle-range
Document the pwm-dutycycle-unit and pwm-dutycycle-range properties. Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com> Acked-by: Brian Norris <briannorris@chromium.org> Acked-by: Rob Herring <robh@kernel.org> Acked-by: Mark Brown <broonie@kernel.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
Diffstat (limited to 'Documentation/devicetree/bindings')
-rw-r--r--Documentation/devicetree/bindings/regulator/pwm-regulator.txt19
1 files changed, 19 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/regulator/pwm-regulator.txt b/Documentation/devicetree/bindings/regulator/pwm-regulator.txt
index dd6f59cf1455..3aeba9f86ed8 100644
--- a/Documentation/devicetree/bindings/regulator/pwm-regulator.txt
+++ b/Documentation/devicetree/bindings/regulator/pwm-regulator.txt
@@ -34,6 +34,18 @@ Only required for Voltage Table Mode:
First cell is voltage in microvolts (uV)
Second cell is duty-cycle in percent (%)
+Optional properties for Continuous mode:
+- pwm-dutycycle-unit: Integer value encoding the duty cycle unit. If not
+ defined, <100> is assumed, meaning that
+ pwm-dutycycle-range contains values expressed in
+ percent.
+
+- pwm-dutycycle-range: Should contain 2 entries. The first entry is encoding
+ the dutycycle for regulator-min-microvolt and the
+ second one the dutycycle for regulator-max-microvolt.
+ Duty cycle values are expressed in pwm-dutycycle-unit.
+ If not defined, <0 100> is assumed.
+
NB: To be clear, if voltage-table is provided, then the device will be used
in Voltage Table Mode. If no voltage-table is provided, then the device will
be used in Continuous Voltage Mode.
@@ -53,6 +65,13 @@ Continuous Voltage With Enable GPIO Example:
regulator-min-microvolt = <1016000>;
regulator-max-microvolt = <1114000>;
regulator-name = "vdd_logic";
+ /* unit == per-mille */
+ pwm-dutycycle-unit = <1000>;
+ /*
+ * Inverted PWM logic, and the duty cycle range is limited
+ * to 30%-70%.
+ */
+ pwm-dutycycle-range <700 300>; /* */
};
Voltage Table Example:
OpenPOWER on IntegriCloud