diff options
author | Finn Thain <fthain@telegraphics.com.au> | 2018-05-09 11:04:48 +1000 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2018-05-14 16:27:08 +0200 |
commit | bdeeed098811b36d1f988521600a89a400830a4b (patch) | |
tree | 7447eae93d4e230c85f70eee6ea57c95f3566784 /Documentation/clearing-warn-once.txt | |
parent | 6be5b5b9c5e0104b009cf6996e4df21877576b91 (diff) | |
download | blackbird-op-linux-bdeeed098811b36d1f988521600a89a400830a4b.tar.gz blackbird-op-linux-bdeeed098811b36d1f988521600a89a400830a4b.zip |
nubus: Call bus_register unconditionally
Loading a NuBus driver module on a non-NuBus machine triggers the
BUG_ON(!drv->bus->p) in driver_register(), because bus_register() was
not called, because it is conditional on MACH_IS_MAC.
Fix the crash by calling bus_register() unconditionally. Call it from
a postcore_initcall(), like other busses do.
Hence, the bus type is available for device_register(), which happens
in a subsys initcall, and for driver_register(), which happens in a
device or module initcall.
Cc: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Reported-by: Michael Schmitz <schmitzmic@gmail.com>
Tested-by: Stan Johnson <userm57@yahoo.com>
Fixes: 7f86c765a6a2 ("nubus: Add support for the driver model")
Signed-off-by: Finn Thain <fthain@telegraphics.com.au>
Reviewed-by: Geert Uytterhoeven <geert@linux-m68k.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'Documentation/clearing-warn-once.txt')
0 files changed, 0 insertions, 0 deletions