summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorArnd Bergmann <arnd@arndb.de>2018-11-02 16:44:13 +0100
committerMartin K. Petersen <martin.petersen@oracle.com>2018-11-05 22:35:01 -0500
commit77409c4cdc44560e1b3b839e62d7f73478199680 (patch)
tree9c81699623c047c86be545defeaa8ed5649e9df7
parentf8d294324598ec85bea2779512e48c94cbe4d7c6 (diff)
downloadblackbird-op-linux-77409c4cdc44560e1b3b839e62d7f73478199680.tar.gz
blackbird-op-linux-77409c4cdc44560e1b3b839e62d7f73478199680.zip
scsi: myrs: avoid stack overflow warning
Putting a 1024 byte data structure on the stack is generally a bad idea. On 32-bit systems, it also triggers a compile-time warning when building with -Og: drivers/scsi/myrs.c: In function 'myrs_get_ctlr_info': drivers/scsi/myrs.c:212:1: error: the frame size of 1028 bytes is larger than 1024 bytes [-Werror=frame-larger-than=] We only really need three members of the structure, so just read them manually here instead of copying the entire structure. Fixes: 77266186397c ("scsi: myrs: Add Mylex RAID controller (SCSI interface)") Signed-off-by: Arnd Bergmann <arnd@arndb.de> Reviewed-by: Hannes Reinecke <hare@suse.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-rw-r--r--drivers/scsi/myrs.c13
1 files changed, 8 insertions, 5 deletions
diff --git a/drivers/scsi/myrs.c b/drivers/scsi/myrs.c
index 0264a2e2bc19..b8d54ef8cf6d 100644
--- a/drivers/scsi/myrs.c
+++ b/drivers/scsi/myrs.c
@@ -163,9 +163,12 @@ static unsigned char myrs_get_ctlr_info(struct myrs_hba *cs)
dma_addr_t ctlr_info_addr;
union myrs_sgl *sgl;
unsigned char status;
- struct myrs_ctlr_info old;
+ unsigned short ldev_present, ldev_critical, ldev_offline;
+
+ ldev_present = cs->ctlr_info->ldev_present;
+ ldev_critical = cs->ctlr_info->ldev_critical;
+ ldev_offline = cs->ctlr_info->ldev_offline;
- memcpy(&old, cs->ctlr_info, sizeof(struct myrs_ctlr_info));
ctlr_info_addr = dma_map_single(&cs->pdev->dev, cs->ctlr_info,
sizeof(struct myrs_ctlr_info),
DMA_FROM_DEVICE);
@@ -198,9 +201,9 @@ static unsigned char myrs_get_ctlr_info(struct myrs_hba *cs)
cs->ctlr_info->rbld_active +
cs->ctlr_info->exp_active != 0)
cs->needs_update = true;
- if (cs->ctlr_info->ldev_present != old.ldev_present ||
- cs->ctlr_info->ldev_critical != old.ldev_critical ||
- cs->ctlr_info->ldev_offline != old.ldev_offline)
+ if (cs->ctlr_info->ldev_present != ldev_present ||
+ cs->ctlr_info->ldev_critical != ldev_critical ||
+ cs->ctlr_info->ldev_offline != ldev_offline)
shost_printk(KERN_INFO, cs->host,
"Logical drive count changes (%d/%d/%d)\n",
cs->ctlr_info->ldev_critical,
OpenPOWER on IntegriCloud