summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorAndrzej Hajda <a.hajda@samsung.com>2018-02-16 15:57:53 +0100
committerSylwester Nawrocki <s.nawrocki@samsung.com>2018-02-23 15:15:16 +0100
commit179db533c08431f509a3823077549773d519358b (patch)
tree90a9b62fc4687a61d2b3cc5702d800e03c723731
parent7e4db0c2836e892766565965207eee051c8037b9 (diff)
downloadblackbird-op-linux-179db533c08431f509a3823077549773d519358b.tar.gz
blackbird-op-linux-179db533c08431f509a3823077549773d519358b.zip
clk: samsung: s3c2410: Fix PLL rates
Rates declared in PLL rate tables should match exactly rates calculated from the PLL coefficients. If that is not the case, rate of the PLL's child clock might be set not as expected. For instance, if in the PLL rates table we have a 393216000 Hz entry and the real value as returned by the PLL's recalc_rate callback is 393216003, after setting PLL's clk rate to 393216000 clk_get_rate will return 393216003. If we now attempt to set rate of a PLL's child divider clock to 393216000/2 its rate will be 131072001, rather than 196608000. That is, the divider will be set to 3 instead of 2, because 393216003/2 is greater than 196608000. To fix this issue declared rates are changed to exactly match rates generated by the PLL, as calculated from the P, M, S, K coefficients. Signed-off-by: Andrzej Hajda <a.hajda@samsung.com> Acked-by: Tomasz Figa <tomasz.figa@gmail.com> Acked-by: Chanwoo Choi <cw00.choi@samsung.com> Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
-rw-r--r--drivers/clk/samsung/clk-s3c2410.c16
1 files changed, 8 insertions, 8 deletions
diff --git a/drivers/clk/samsung/clk-s3c2410.c b/drivers/clk/samsung/clk-s3c2410.c
index e0650c33863b..d8e58a659467 100644
--- a/drivers/clk/samsung/clk-s3c2410.c
+++ b/drivers/clk/samsung/clk-s3c2410.c
@@ -168,7 +168,7 @@ static struct samsung_pll_rate_table pll_s3c2410_12mhz_tbl[] __initdata = {
PLL_35XX_RATE(226000000, 105, 1, 1),
PLL_35XX_RATE(210000000, 132, 2, 1),
/* 2410 common */
- PLL_35XX_RATE(203000000, 161, 3, 1),
+ PLL_35XX_RATE(202800000, 161, 3, 1),
PLL_35XX_RATE(192000000, 88, 1, 1),
PLL_35XX_RATE(186000000, 85, 1, 1),
PLL_35XX_RATE(180000000, 82, 1, 1),
@@ -178,18 +178,18 @@ static struct samsung_pll_rate_table pll_s3c2410_12mhz_tbl[] __initdata = {
PLL_35XX_RATE(147000000, 90, 2, 1),
PLL_35XX_RATE(135000000, 82, 2, 1),
PLL_35XX_RATE(124000000, 116, 1, 2),
- PLL_35XX_RATE(118000000, 150, 2, 2),
+ PLL_35XX_RATE(118500000, 150, 2, 2),
PLL_35XX_RATE(113000000, 105, 1, 2),
- PLL_35XX_RATE(101000000, 127, 2, 2),
+ PLL_35XX_RATE(101250000, 127, 2, 2),
PLL_35XX_RATE(90000000, 112, 2, 2),
- PLL_35XX_RATE(85000000, 105, 2, 2),
+ PLL_35XX_RATE(84750000, 105, 2, 2),
PLL_35XX_RATE(79000000, 71, 1, 2),
- PLL_35XX_RATE(68000000, 82, 2, 2),
- PLL_35XX_RATE(56000000, 142, 2, 3),
+ PLL_35XX_RATE(67500000, 82, 2, 2),
+ PLL_35XX_RATE(56250000, 142, 2, 3),
PLL_35XX_RATE(48000000, 120, 2, 3),
- PLL_35XX_RATE(51000000, 161, 3, 3),
+ PLL_35XX_RATE(50700000, 161, 3, 3),
PLL_35XX_RATE(45000000, 82, 1, 3),
- PLL_35XX_RATE(34000000, 82, 2, 3),
+ PLL_35XX_RATE(33750000, 82, 2, 3),
{ /* sentinel */ },
};
OpenPOWER on IntegriCloud