summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/phy/phy-mtk-tphy.txt
blob: 41e09ed2ca70e2caaf7ee65b2f67651fba7bb9f4 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
MediaTek T-PHY binding
--------------------------

T-phy controller supports physical layer functionality for a number of
controllers on MediaTek SoCs, such as, USB2.0, USB3.0, PCIe, and SATA.

Required properties (controller (parent) node):
 - compatible	: should be one of
		  "mediatek,generic-tphy-v1"
		  "mediatek,generic-tphy-v2"
		  "mediatek,mt2701-u3phy" (deprecated)
		  "mediatek,mt2712-u3phy" (deprecated)
		  "mediatek,mt8173-u3phy";
		  make use of "mediatek,generic-tphy-v1" on mt2701 instead and
		  "mediatek,generic-tphy-v2" on mt2712 instead.
 - clocks	: (deprecated, use port's clocks instead) a list of phandle +
		  clock-specifier pairs, one for each entry in clock-names
 - clock-names	: (deprecated, use port's one instead) must contain
		  "u3phya_ref": for reference clock of usb3.0 analog phy.

Required nodes	: a sub-node is required for each port the controller
		  provides. Address range information including the usual
		  'reg' property is used inside these nodes to describe
		  the controller's topology.

Optional properties (controller (parent) node):
 - reg		: offset and length of register shared by multiple ports,
		  exclude port's private register. It is needed on mt2701
		  and mt8173, but not on mt2712.

Required properties (port (child) node):
- reg		: address and length of the register set for the port.
- clocks	: a list of phandle + clock-specifier pairs, one for each
		  entry in clock-names
- clock-names	: must contain
		  "ref": 48M reference clock for HighSpeed analog phy; and 26M
			reference clock for SuperSpeed analog phy, sometimes is
			24M, 25M or 27M, depended on platform.
- #phy-cells	: should be 1 (See second example)
		  cell after port phandle is phy type from:
			- PHY_TYPE_USB2
			- PHY_TYPE_USB3
			- PHY_TYPE_PCIE
			- PHY_TYPE_SATA

Example:

u3phy: usb-phy@11290000 {
	compatible = "mediatek,mt8173-u3phy";
	reg = <0 0x11290000 0 0x800>;
	#address-cells = <2>;
	#size-cells = <2>;
	ranges;

	u2port0: usb-phy@11290800 {
		reg = <0 0x11290800 0 0x100>;
		clocks = <&apmixedsys CLK_APMIXED_REF2USB_TX>;
		clock-names = "ref";
		#phy-cells = <1>;
	};

	u3port0: usb-phy@11290900 {
		reg = <0 0x11290800 0 0x700>;
		clocks = <&clk26m>;
		clock-names = "ref";
		#phy-cells = <1>;
	};

	u2port1: usb-phy@11291000 {
		reg = <0 0x11291000 0 0x100>;
		clocks = <&apmixedsys CLK_APMIXED_REF2USB_TX>;
		clock-names = "ref";
		#phy-cells = <1>;
	};
};

Specifying phy control of devices
---------------------------------

Device nodes should specify the configuration required in their "phys"
property, containing a phandle to the phy port node and a device type;
phy-names for each port are optional.

Example:

#include <dt-bindings/phy/phy.h>

usb30: usb@11270000 {
	...
	phys = <&u2port0 PHY_TYPE_USB2>, <&u3port0 PHY_TYPE_USB3>;
	phy-names = "usb2-0", "usb3-0";
	...
};


Layout differences of banks between mt8173/mt2701 and mt2712
-------------------------------------------------------------
mt8173 and mt2701:
port        offset    bank
shared      0x0000    SPLLC
            0x0100    FMREG
u2 port0    0x0800    U2PHY_COM
u3 port0    0x0900    U3PHYD
            0x0a00    U3PHYD_BANK2
            0x0b00    U3PHYA
            0x0c00    U3PHYA_DA
u2 port1    0x1000    U2PHY_COM
u3 port1    0x1100    U3PHYD
            0x1200    U3PHYD_BANK2
            0x1300    U3PHYA
            0x1400    U3PHYA_DA
u2 port2    0x1800    U2PHY_COM
            ...

mt2712:
port        offset    bank
u2 port0    0x0000    MISC
            0x0100    FMREG
            0x0300    U2PHY_COM
u3 port0    0x0700    SPLLC
            0x0800    CHIP
            0x0900    U3PHYD
            0x0a00    U3PHYD_BANK2
            0x0b00    U3PHYA
            0x0c00    U3PHYA_DA
u2 port1    0x1000    MISC
            0x1100    FMREG
            0x1300    U2PHY_COM
u3 port1    0x1700    SPLLC
            0x1800    CHIP
            0x1900    U3PHYD
            0x1a00    U3PHYD_BANK2
            0x1b00    U3PHYA
            0x1c00    U3PHYA_DA
u2 port2    0x2000    MISC
            ...

    SPLLC shared by u3 ports and FMREG shared by u2 ports on
mt8173/mt2701 are put back into each port; a new bank MISC for
u2 ports and CHIP for u3 ports are added on mt2712.
OpenPOWER on IntegriCloud