summaryrefslogtreecommitdiffstats
path: root/drivers/message/fusion/lsi/mpi_ioc.h
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/message/fusion/lsi/mpi_ioc.h')
-rw-r--r--drivers/message/fusion/lsi/mpi_ioc.h22
1 files changed, 20 insertions, 2 deletions
diff --git a/drivers/message/fusion/lsi/mpi_ioc.h b/drivers/message/fusion/lsi/mpi_ioc.h
index 5cbb6bd048e1..8faa4fab7b89 100644
--- a/drivers/message/fusion/lsi/mpi_ioc.h
+++ b/drivers/message/fusion/lsi/mpi_ioc.h
@@ -1,12 +1,12 @@
/*
- * Copyright (c) 2000-2007 LSI Corporation.
+ * Copyright (c) 2000-2008 LSI Corporation.
*
*
* Name: mpi_ioc.h
* Title: MPI IOC, Port, Event, FW Download, and FW Upload messages
* Creation Date: August 11, 2000
*
- * mpi_ioc.h Version: 01.05.14
+ * mpi_ioc.h Version: 01.05.16
*
* Version History
* ---------------
@@ -113,6 +113,16 @@
* added _MULTI_PORT_DOMAIN.
* 05-24-07 01.05.14 Added Common Boot Block type to FWDownload Request.
* Added Common Boot Block type to FWUpload Request.
+ * 08-07-07 01.05.15 Added MPI_EVENT_SAS_INIT_RC_REMOVED define.
+ * Added MPI_EVENT_IR2_RC_DUAL_PORT_ADDED and
+ * MPI_EVENT_IR2_RC_DUAL_PORT_REMOVED for IR2 event data.
+ * Added SASAddress field to SAS Initiator Device Table
+ * Overflow event data structure.
+ * 03-28-08 01.05.16 Added two new ReasonCode values to SAS Device Status
+ * Change Event data to indicate completion of internally
+ * generated task management.
+ * Added MPI_EVENT_DSCVRY_ERR_DS_SATA_INIT_FAILURE define.
+ * Added MPI_EVENT_SAS_INIT_RC_INACCESSIBLE define.
* --------------------------------------------------------------------------
*/
@@ -612,6 +622,8 @@ typedef struct _EVENT_DATA_SAS_DEVICE_STATUS_CHANGE
#define MPI_EVENT_SAS_DEV_STAT_RC_CLEAR_TASK_SET_INTERNAL (0x0B)
#define MPI_EVENT_SAS_DEV_STAT_RC_QUERY_TASK_INTERNAL (0x0C)
#define MPI_EVENT_SAS_DEV_STAT_RC_ASYNC_NOTIFICATION (0x0D)
+#define MPI_EVENT_SAS_DEV_STAT_RC_CMPL_INTERNAL_DEV_RESET (0x0E)
+#define MPI_EVENT_SAS_DEV_STAT_RC_CMPL_TASK_ABORT_INTERNAL (0x0F)
/* SCSI Event data for Queue Full event */
@@ -708,6 +720,8 @@ typedef struct _MPI_EVENT_DATA_IR2
#define MPI_EVENT_IR2_RC_PD_REMOVED (0x05)
#define MPI_EVENT_IR2_RC_FOREIGN_CFG_DETECTED (0x06)
#define MPI_EVENT_IR2_RC_REBUILD_MEDIUM_ERROR (0x07)
+#define MPI_EVENT_IR2_RC_DUAL_PORT_ADDED (0x08)
+#define MPI_EVENT_IR2_RC_DUAL_PORT_REMOVED (0x09)
/* defines for logical disk states */
#define MPI_LD_STATE_OPTIMAL (0x00)
@@ -867,6 +881,7 @@ typedef struct _EVENT_DATA_DISCOVERY_ERROR
#define MPI_EVENT_DSCVRY_ERR_DS_UNSUPPORTED_DEVICE (0x00000800)
#define MPI_EVENT_DSCVRY_ERR_DS_MAX_SATA_TARGETS (0x00001000)
#define MPI_EVENT_DSCVRY_ERR_DS_MULTI_PORT_DOMAIN (0x00002000)
+#define MPI_EVENT_DSCVRY_ERR_DS_SATA_INIT_FAILURE (0x00004000)
/* SAS SMP Error Event data */
@@ -902,6 +917,8 @@ typedef struct _EVENT_DATA_SAS_INIT_DEV_STATUS_CHANGE
/* defines for the ReasonCode field of the SAS Initiator Device Status Change event */
#define MPI_EVENT_SAS_INIT_RC_ADDED (0x01)
+#define MPI_EVENT_SAS_INIT_RC_REMOVED (0x02)
+#define MPI_EVENT_SAS_INIT_RC_INACCESSIBLE (0x03)
/* SAS Initiator Device Table Overflow Event data */
@@ -910,6 +927,7 @@ typedef struct _EVENT_DATA_SAS_INIT_TABLE_OVERFLOW
U8 MaxInit; /* 00h */
U8 CurrentInit; /* 01h */
U16 Reserved1; /* 02h */
+ U64 SASAddress; /* 04h */
} EVENT_DATA_SAS_INIT_TABLE_OVERFLOW,
MPI_POINTER PTR_EVENT_DATA_SAS_INIT_TABLE_OVERFLOW,
MpiEventDataSasInitTableOverflow_t,
OpenPOWER on IntegriCloud