thermal: use integers rather than strings for thermal values
The thermal API currently uses strings to pass values to userspace. This makes it difficult to use from within the kernel. Change the interface to use integers and fix up the consumers. Signed-off-by: Matthew Garrett <mjg@redhat.com> Acked-by: Zhang Rui <rui.zhang@intel.com> Acked-by: Thomas Renninger <trenn@suse.de> Signed-off-by: Len Brown <len.brown@intel.com>
Diffstat (limited to 'include/linux/thermal.h')
-rw-r--r--include/linux/thermal.h32
1 files changed, 24 insertions, 8 deletions
diff --git a/include/linux/thermal.h b/include/linux/thermal.h
index 917707e6151d..4cb3292fb6e4 100644
--- a/include/linux/thermal.h
+++ b/include/linux/thermal.h
@@ -31,23 +31,39 @@
struct thermal_zone_device;
struct thermal_cooling_device;
+enum thermal_device_mode {
+ THERMAL_DEVICE_DISABLED = 0,
+ THERMAL_DEVICE_ENABLED,
+};
+
+enum thermal_trip_type {
+ THERMAL_TRIP_ACTIVE = 0,
+ THERMAL_TRIP_PASSIVE,
+ THERMAL_TRIP_HOT,
+ THERMAL_TRIP_CRITICAL,
+};
+
struct thermal_zone_device_ops {
int (*bind) (struct thermal_zone_device *,
struct thermal_cooling_device *);
int (*unbind) (struct thermal_zone_device *,
struct thermal_cooling_device *);
- int (*get_temp) (struct thermal_zone_device *, char *);
- int (*get_mode) (struct thermal_zone_device *, char *);
- int (*set_mode) (struct thermal_zone_device *, const char *);
- int (*get_trip_type) (struct thermal_zone_device *, int, char *);
- int (*get_trip_temp) (struct thermal_zone_device *, int, char *);
+ int (*get_temp) (struct thermal_zone_device *, unsigned long *);
+ int (*get_mode) (struct thermal_zone_device *,
+ enum thermal_device_mode *);
+ int (*set_mode) (struct thermal_zone_device *,
+ enum thermal_device_mode);
+ int (*get_trip_type) (struct thermal_zone_device *, int,
+ enum thermal_trip_type *);
+ int (*get_trip_temp) (struct thermal_zone_device *, int,
+ unsigned long *);
int (*get_crit_temp) (struct thermal_zone_device *, unsigned long *);
};
struct thermal_cooling_device_ops {
- int (*get_max_state) (struct thermal_cooling_device *, char *);
- int (*get_cur_state) (struct thermal_cooling_device *, char *);
- int (*set_cur_state) (struct thermal_cooling_device *, unsigned int);
+ int (*get_max_state) (struct thermal_cooling_device *, unsigned long *);
+ int (*get_cur_state) (struct thermal_cooling_device *, unsigned long *);
+ int (*set_cur_state) (struct thermal_cooling_device *, unsigned long);
};
#define THERMAL_TRIPS_NONE -1