summaryrefslogtreecommitdiffstats
path: root/fs/nfsd
diff options
context:
space:
mode:
authorBenjamin Coddington <bcodding@redhat.com>2018-06-19 04:57:24 -0400
committerJ. Bruce Fields <bfields@redhat.com>2018-06-19 10:12:31 -0400
commit8163496e78db100a6b5cfbdaece385686ae50129 (patch)
tree10d7798429edd25a56fb8769c18ddbfebf30aa0c /fs/nfsd
parent5b7b15aee641904ae269be9846610a3950cbd64c (diff)
downloadblackbird-obmc-linux-8163496e78db100a6b5cfbdaece385686ae50129.tar.gz
blackbird-obmc-linux-8163496e78db100a6b5cfbdaece385686ae50129.zip
nfsd: don't advertise a SCSI layout for an unsupported request_queue
Commit 30181faae37f ("nfsd: Check queue type before submitting a SCSI request") did the work of ensuring that we don't send SCSI requests to a request queue that won't support them, but that check is in the GETDEVICEINFO path. Let's not set the SCSI layout in fs_layout_type in the first place, and then we'll have less clients sending GETDEVICEINFO for non-SCSI request queues and less unnecessary WARN_ONs. While we're in here, remove some outdated comments that refer to "overwriting" layout seletion because commit 8a4c3926889e ("nfsd: allow nfsd to advertise multiple layout types") changed things to no longer overwrite the layout type. Signed-off-by: Benjamin Coddington <bcodding@redhat.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: J. Bruce Fields <bfields@redhat.com>
Diffstat (limited to 'fs/nfsd')
-rw-r--r--fs/nfsd/nfs4layouts.c11
1 files changed, 2 insertions, 9 deletions
diff --git a/fs/nfsd/nfs4layouts.c b/fs/nfsd/nfs4layouts.c
index 228faf00a594..2b36aa037ce0 100644
--- a/fs/nfsd/nfs4layouts.c
+++ b/fs/nfsd/nfs4layouts.c
@@ -133,27 +133,20 @@ void nfsd4_setup_layout_type(struct svc_export *exp)
if (!(exp->ex_flags & NFSEXP_PNFS))
return;
- /*
- * If flex file is configured, use it by default. Otherwise
- * check if the file system supports exporting a block-like layout.
- * If the block device supports reservations prefer the SCSI layout,
- * otherwise advertise the block layout.
- */
#ifdef CONFIG_NFSD_FLEXFILELAYOUT
exp->ex_layout_types |= 1 << LAYOUT_FLEX_FILES;
#endif
#ifdef CONFIG_NFSD_BLOCKLAYOUT
- /* overwrite flex file layout selection if needed */
if (sb->s_export_op->get_uuid &&
sb->s_export_op->map_blocks &&
sb->s_export_op->commit_blocks)
exp->ex_layout_types |= 1 << LAYOUT_BLOCK_VOLUME;
#endif
#ifdef CONFIG_NFSD_SCSILAYOUT
- /* overwrite block layout selection if needed */
if (sb->s_export_op->map_blocks &&
sb->s_export_op->commit_blocks &&
- sb->s_bdev && sb->s_bdev->bd_disk->fops->pr_ops)
+ sb->s_bdev && sb->s_bdev->bd_disk->fops->pr_ops &&
+ blk_queue_scsi_passthrough(sb->s_bdev->bd_disk->queue))
exp->ex_layout_types |= 1 << LAYOUT_SCSI;
#endif
}
OpenPOWER on IntegriCloud