authorCédric Le Goater <clg@fr.ibm.com>2015-03-19 18:44:45 +0100
committerGuenter Roeck <linux@roeck-us.net>2015-03-20 08:25:14 -0700
commitfcaf57b67dd03314ade476b847f246ae377160a8 (patch)
treee4dcede2cdd9cc359cb9abec6f25b6d179286893 /drivers
parentf9f54f16bfa1bc76d827d4a2c80f72acbee72b05 (diff)
downloadblackbird-obmc-linux-fcaf57b67dd03314ade476b847f246ae377160a8.tar.gz
blackbird-obmc-linux-fcaf57b67dd03314ade476b847f246ae377160a8.zip
hwmon: (ibmpowernv) do not use the OPAL index for hwmon attribute names
The current OPAL firmware exposes the different sensors of an IBM Power system using node names such as : sensors/amb-temp#1-data sensors/amb-temp#1-thrs cooling-fan#1-data cooling-fan#1-faulted cooling-fan#1-thrs cooling-fan#2-data ... The ibmpowernv driver, when loaded, parses these names to extract the sensor index and the sensor attribute name. Unfortunately, this scheme makes it difficult to add sensors with a different layout (specially of the same type, like temperature) as the sensor index calculated in OPAL is directly used in the hwmon sysfs interface. What this patch does is add a independent hwmon index for each sensor. The increment of the hwmon index (temp, fan, power, etc.) is kept per sensor type in the sensor_group table. The sensor_data table is used to store the association of the hwmon and OPAL indexes, as we need to have the same hwmon index for different attributes of a same sensor. Signed-off-by: Cédric Le Goater <clg@fr.ibm.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/hwmon/ibmpowernv.c23
1 files changed, 22 insertions, 1 deletions
diff --git a/drivers/hwmon/ibmpowernv.c b/drivers/hwmon/ibmpowernv.c
index adfdf59e8f6c..99ca5362dbca 100644
--- a/drivers/hwmon/ibmpowernv.c
+++ b/drivers/hwmon/ibmpowernv.c
@@ -55,6 +55,7 @@ static struct sensor_group {
const char *compatible;
struct attribute_group group;
u32 attr_count;
+ u32 hwmon_index;
} sensor_groups[] = {
{"fan", "ibm,opal-sensor-cooling-fan"},
{"temp", "ibm,opal-sensor-amb-temp"},
@@ -64,6 +65,8 @@ static struct sensor_group {
struct sensor_data {
u32 id; /* An opaque id of the firmware for each sensor */
+ u32 hwmon_index;
+ u32 opal_index;
enum sensors type;
char name[MAX_ATTR_LEN];
struct device_attribute dev_attr;
@@ -181,6 +184,19 @@ static int get_sensor_type(struct device_node *np)
return MAX_SENSOR_TYPE;
}
+static u32 get_sensor_hwmon_index(struct sensor_data *sdata,
+ struct sensor_data *sdata_table, int count)
+{
+ int i;
+
+ for (i = 0; i < count; i++)
+ if (sdata_table[i].opal_index == sdata->opal_index &&
+ sdata_table[i].type == sdata->type)
+ return sdata_table[i].hwmon_index;
+
+ return ++sensor_groups[sdata->type].hwmon_index;
+}
+
static int populate_attr_groups(struct platform_device *pdev)
{
struct platform_data *pdata = platform_get_drvdata(pdev);
@@ -270,8 +286,13 @@ static int create_device_attrs(struct platform_device *pdev)
goto exit_put_node;
}
+ sdata[count].opal_index = opal_index;
+ sdata[count].hwmon_index =
+ get_sensor_hwmon_index(&sdata[count], sdata, count);
+
snprintf(sdata[count].name, MAX_ATTR_LEN, "%s%d_%s",
- sensor_groups[type].name, opal_index, attr_name);
+ sensor_groups[type].name, sdata[count].hwmon_index,
+ attr_name);
sysfs_attr_init(&sdata[count].dev_attr.attr);
sdata[count].dev_attr.attr.name = sdata[count].name;