summaryrefslogtreecommitdiffstats
path: root/drivers/scsi/megaraid
diff options
context:
space:
mode:
authorYang, Bo <Bo.Yang@lsi.com>2009-10-06 14:33:06 -0600
committerJames Bottomley <James.Bottomley@suse.de>2009-10-29 13:03:19 -0400
commit044833b572b96afe91506a0edec42efd84ba4939 (patch)
tree51b603f30279efd721690bbf9e7b0763eaf34a1a /drivers/scsi/megaraid
parent81e403ce3c6a34cd705bf54d4cdeefdeb7068a8d (diff)
downloadblackbird-obmc-linux-044833b572b96afe91506a0edec42efd84ba4939.tar.gz
blackbird-obmc-linux-044833b572b96afe91506a0edec42efd84ba4939.zip
[SCSI] megaraid_sas: report system PDs to OS
When OS issue inquiry, it will check driver's internal pd_list. Signed-off-by Bo Yang<bo.yang@lsi.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Diffstat (limited to 'drivers/scsi/megaraid')
-rw-r--r--drivers/scsi/megaraid/megaraid_sas.c91
1 files changed, 65 insertions, 26 deletions
diff --git a/drivers/scsi/megaraid/megaraid_sas.c b/drivers/scsi/megaraid/megaraid_sas.c
index 48c3658d73a7..9967ee72a967 100644
--- a/drivers/scsi/megaraid/megaraid_sas.c
+++ b/drivers/scsi/megaraid/megaraid_sas.c
@@ -1115,24 +1115,76 @@ megasas_queue_command(struct scsi_cmnd *scmd, void (*done) (struct scsi_cmnd *))
return 0;
}
+static struct megasas_instance *megasas_lookup_instance(u16 host_no)
+{
+ int i;
+
+ for (i = 0; i < megasas_mgmt_info.max_index; i++) {
+
+ if ((megasas_mgmt_info.instance[i]) &&
+ (megasas_mgmt_info.instance[i]->host->host_no == host_no))
+ return megasas_mgmt_info.instance[i];
+ }
+
+ return NULL;
+}
+
static int megasas_slave_configure(struct scsi_device *sdev)
{
+ u16 pd_index = 0;
+ struct megasas_instance *instance ;
+
+ instance = megasas_lookup_instance(sdev->host->host_no);
+
/*
- * Don't export physical disk devices to the disk driver.
- *
- * FIXME: Currently we don't export them to the midlayer at all.
- * That will be fixed once LSI engineers have audited the
- * firmware for possible issues.
- */
- if (sdev->channel < MEGASAS_MAX_PD_CHANNELS && sdev->type == TYPE_DISK)
+ * Don't export physical disk devices to the disk driver.
+ *
+ * FIXME: Currently we don't export them to the midlayer at all.
+ * That will be fixed once LSI engineers have audited the
+ * firmware for possible issues.
+ */
+ if (sdev->channel < MEGASAS_MAX_PD_CHANNELS &&
+ sdev->type == TYPE_DISK) {
+ pd_index = (sdev->channel * MEGASAS_MAX_DEV_PER_CHANNEL) +
+ sdev->id;
+ if (instance->pd_list[pd_index].driveState ==
+ MR_PD_STATE_SYSTEM) {
+ blk_queue_rq_timeout(sdev->request_queue,
+ MEGASAS_DEFAULT_CMD_TIMEOUT * HZ);
+ return 0;
+ }
return -ENXIO;
+ }
/*
- * The RAID firmware may require extended timeouts.
- */
- if (sdev->channel >= MEGASAS_MAX_PD_CHANNELS)
- blk_queue_rq_timeout(sdev->request_queue,
- MEGASAS_DEFAULT_CMD_TIMEOUT * HZ);
+ * The RAID firmware may require extended timeouts.
+ */
+ blk_queue_rq_timeout(sdev->request_queue,
+ MEGASAS_DEFAULT_CMD_TIMEOUT * HZ);
+ return 0;
+}
+
+static int megasas_slave_alloc(struct scsi_device *sdev)
+{
+ u16 pd_index = 0;
+ struct megasas_instance *instance ;
+ instance = megasas_lookup_instance(sdev->host->host_no);
+ if ((sdev->channel < MEGASAS_MAX_PD_CHANNELS) &&
+ (sdev->type == TYPE_DISK)) {
+ /*
+ * Open the OS scan to the SYSTEM PD
+ */
+ pd_index =
+ (sdev->channel * MEGASAS_MAX_DEV_PER_CHANNEL) +
+ sdev->id;
+ if ((instance->pd_list[pd_index].driveState ==
+ MR_PD_STATE_SYSTEM) &&
+ (instance->pd_list[pd_index].driveType ==
+ TYPE_DISK)) {
+ return 0;
+ }
+ return -ENXIO;
+ }
return 0;
}
@@ -1423,6 +1475,7 @@ static struct scsi_host_template megasas_template = {
.name = "LSI SAS based MegaRAID driver",
.proc_name = "megaraid_sas",
.slave_configure = megasas_slave_configure,
+ .slave_alloc = megasas_slave_alloc,
.queuecommand = megasas_queue_command,
.eh_device_reset_handler = megasas_reset_device,
.eh_bus_reset_handler = megasas_reset_bus_host,
@@ -3455,20 +3508,6 @@ megasas_mgmt_fw_ioctl(struct megasas_instance *instance,
return error;
}
-static struct megasas_instance *megasas_lookup_instance(u16 host_no)
-{
- int i;
-
- for (i = 0; i < megasas_mgmt_info.max_index; i++) {
-
- if ((megasas_mgmt_info.instance[i]) &&
- (megasas_mgmt_info.instance[i]->host->host_no == host_no))
- return megasas_mgmt_info.instance[i];
- }
-
- return NULL;
-}
-
static int megasas_mgmt_ioctl_fw(struct file *file, unsigned long arg)
{
struct megasas_iocpacket __user *user_ioc =
OpenPOWER on IntegriCloud