authorGreg Rose <gregory.v.rose@intel.com>2013-01-19 06:40:22 +0000
committerJeff Kirsher <jeffrey.t.kirsher@intel.com>2013-01-23 14:34:13 -0800
commitb876a744a228308ecf75466831453f0863d253db (patch)
tree835523eea4a2691c20a1f8d208705bad68173619 /drivers/net/ethernet/intel/ixgbevf
parent43dc4e0158a343e4f6dc400b925bf4a945f4978b (diff)
downloadblackbird-obmc-linux-b876a744a228308ecf75466831453f0863d253db.tar.gz
blackbird-obmc-linux-b876a744a228308ecf75466831453f0863d253db.zip
ixgbevf: Fix link speed message to support 100Mbps
The X540 can link at 100Mbps - fix the link speed indicator message to show that value. Signed-off-by: Greg Rose <gregory.v.rose@intel.com> Tested-by: Sibai Li <sibai.li@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Diffstat (limited to 'drivers/net/ethernet/intel/ixgbevf')
-rw-r--r--drivers/net/ethernet/intel/ixgbevf/ixgbevf_main.c19
1 files changed, 16 insertions, 3 deletions
diff --git a/drivers/net/ethernet/intel/ixgbevf/ixgbevf_main.c b/drivers/net/ethernet/intel/ixgbevf/ixgbevf_main.c
index 551e31dc25c5..c3db6cd69b68 100644
--- a/drivers/net/ethernet/intel/ixgbevf/ixgbevf_main.c
+++ b/drivers/net/ethernet/intel/ixgbevf/ixgbevf_main.c
@@ -2245,10 +2245,23 @@ static void ixgbevf_watchdog_task(struct work_struct *work)
if (link_up) {
if (!netif_carrier_ok(netdev)) {
+ char *link_speed_string;
+ switch (link_speed) {
+ case IXGBE_LINK_SPEED_10GB_FULL:
+ link_speed_string = "10 Gbps";
+ break;
+ case IXGBE_LINK_SPEED_1GB_FULL:
+ link_speed_string = "1 Gbps";
+ break;
+ case IXGBE_LINK_SPEED_100_FULL:
+ link_speed_string = "100 Mbps";
+ break;
+ default:
+ link_speed_string = "unknown speed";
+ break;
+ }
dev_info(&adapter->pdev->dev,
- "NIC Link is Up, %u Gbps\n",
- (link_speed == IXGBE_LINK_SPEED_10GB_FULL) ?
- 10 : 1);
+ "NIC Link is Up, %s\n", link_speed_string);
netif_carrier_on(netdev);
netif_tx_wake_all_queues(netdev);
}