[PATCH] e1000: Fix SoL/IDER link and loopback
Fix so that if a SoL/IDER session is active, do not allow operations which require a PHY reset and instead log a message. Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com> Signed-off-by: Jesse Brandeburg <jesse.brandeburg@intel.com> Signed-off-by: John Ronciak <john.ronciak@intel.com> Signed-off-by: Jeff Garzik <jgarzik@pobox.com>
Diffstat (limited to 'drivers/net/e1000/e1000_main.c')
-rw-r--r--drivers/net/e1000/e1000_main.c16
1 files changed, 11 insertions, 5 deletions
diff --git a/drivers/net/e1000/e1000_main.c b/drivers/net/e1000/e1000_main.c
index 22c8286a4849..66cf1748ba9b 100644
--- a/drivers/net/e1000/e1000_main.c
+++ b/drivers/net/e1000/e1000_main.c
@@ -378,6 +378,8 @@ void
e1000_down(struct e1000_adapter *adapter)
{
struct net_device *netdev = adapter->netdev;
+ boolean_t mng_mode_enabled = (adapter->hw.mac_type >= e1000_82571) &&
+ e1000_check_mng_mode(&adapter->hw);
e1000_irq_disable(adapter);
#ifdef CONFIG_E1000_MQ
@@ -405,12 +407,16 @@ e1000_down(struct e1000_adapter *adapter)
e1000_clean_all_tx_rings(adapter);
e1000_clean_all_rx_rings(adapter);
- /* If WoL is not enabled and management mode is not IAMT
- * Power down the PHY so no link is implied when interface is down */
- if(!adapter->wol && adapter->hw.mac_type >= e1000_82540 &&
+ /* Power down the PHY so no link is implied when interface is down *
+ * The PHY cannot be powered down if any of the following is TRUE *
+ * (a) WoL is enabled
+ * (b) AMT is active
+ * (c) SoL/IDER session is active */
+ if (!adapter->wol && adapter->hw.mac_type >= e1000_82540 &&
adapter->hw.media_type == e1000_media_type_copper &&
- !e1000_check_mng_mode(&adapter->hw) &&
- !(E1000_READ_REG(&adapter->hw, MANC) & E1000_MANC_SMBUS_EN)) {
+ !(E1000_READ_REG(&adapter->hw, MANC) & E1000_MANC_SMBUS_EN) &&
+ !mng_mode_enabled &&
+ !e1000_check_phy_reset_block(&adapter->hw)) {
uint16_t mii_reg;
e1000_read_phy_reg(&adapter->hw, PHY_CTRL, &mii_reg);
mii_reg |= MII_CR_POWER_DOWN;
OpenPOWER on IntegriCloud