diff options
author | Ben Widawsky <ben@bwidawsk.net> | 2014-12-15 12:26:46 -0800 |
---|---|---|
committer | Daniel Vetter <daniel.vetter@ffwll.ch> | 2014-12-16 08:56:55 +0100 |
commit | b04d4a38c0691e4467fa2988b6fe481bf759daaf (patch) | |
tree | 5bc4d0f0df284ac0f60894fa0a0904e34d6003c0 /drivers/gpu/drm/drm_cache.c | |
parent | 7432ca5acec8a24a7e576c92d28449e2d790b734 (diff) | |
download | blackbird-obmc-linux-b04d4a38c0691e4467fa2988b6fe481bf759daaf.tar.gz blackbird-obmc-linux-b04d4a38c0691e4467fa2988b6fe481bf759daaf.zip |
drm/cache: Use wbinvd helpers
When the original drm code was written there were no centralized functions for
doing a coordinated wbinvd across all CPUs. Now (since 2010) there are, so use
them instead of rolling a new one.
v2: On x86 UP systems the wbinvd_on_all_cpus() is defined as a static inline in
smp.h. We must therefore include this file so we don't get compiler errors.
This error was found by 0-DAY kernel test infrastructure. We only need this for
x86.
Cc: Intel GFX <intel-gfx@lists.freedesktop.org>
Signed-off-by: Ben Widawsky <ben@bwidawsk.net>
Reviewed-by: Chris Wilson <chris@chris-wilson.co.uk> (v1)
Signed-off-by: Daniel Vetter <daniel.vetter@ffwll.ch>
Diffstat (limited to 'drivers/gpu/drm/drm_cache.c')
-rw-r--r-- | drivers/gpu/drm/drm_cache.c | 13 |
1 files changed, 4 insertions, 9 deletions
diff --git a/drivers/gpu/drm/drm_cache.c b/drivers/gpu/drm/drm_cache.c index a6b690626a6b..9a62d7a53553 100644 --- a/drivers/gpu/drm/drm_cache.c +++ b/drivers/gpu/drm/drm_cache.c @@ -32,6 +32,7 @@ #include <drm/drmP.h> #if defined(CONFIG_X86) +#include <asm/smp.h> /* * clflushopt is an unordered instruction which needs fencing with mfence or @@ -64,12 +65,6 @@ static void drm_cache_flush_clflush(struct page *pages[], drm_clflush_page(*pages++); mb(); } - -static void -drm_clflush_ipi_handler(void *null) -{ - wbinvd(); -} #endif void @@ -82,7 +77,7 @@ drm_clflush_pages(struct page *pages[], unsigned long num_pages) return; } - if (on_each_cpu(drm_clflush_ipi_handler, NULL, 1) != 0) + if (wbinvd_on_all_cpus()) printk(KERN_ERR "Timed out waiting for cache flush.\n"); #elif defined(__powerpc__) @@ -121,7 +116,7 @@ drm_clflush_sg(struct sg_table *st) return; } - if (on_each_cpu(drm_clflush_ipi_handler, NULL, 1) != 0) + if (wbinvd_on_all_cpus()) printk(KERN_ERR "Timed out waiting for cache flush.\n"); #else printk(KERN_ERR "Architecture has no drm_cache.c support\n"); @@ -144,7 +139,7 @@ drm_clflush_virt_range(void *addr, unsigned long length) return; } - if (on_each_cpu(drm_clflush_ipi_handler, NULL, 1) != 0) + if (wbinvd_on_all_cpus()) printk(KERN_ERR "Timed out waiting for cache flush.\n"); #else printk(KERN_ERR "Architecture has no drm_cache.c support\n"); |