summaryrefslogtreecommitdiffstats
path: root/arch/x86/kernel/cpu
diff options
context:
space:
mode:
authorXie XiuQi <xiexiuqi@huawei.com>2015-05-26 10:28:21 +0200
committerIngo Molnar <mingo@kernel.org>2015-05-27 14:39:14 +0200
commit5c31b2800d8d3e735e5ecac8fc13d1cf862fd330 (patch)
tree86e596c275928af284093a993593abd2580544ad /arch/x86/kernel/cpu
parent4ddf2a178570c9db2935206f3b0bdfea08f3c905 (diff)
downloadblackbird-obmc-linux-5c31b2800d8d3e735e5ecac8fc13d1cf862fd330.tar.gz
blackbird-obmc-linux-5c31b2800d8d3e735e5ecac8fc13d1cf862fd330.zip
x86/mce: Fix monarch timeout setting through the mce= cmdline option
Using "mce=1,10000000" on the kernel cmdline to change the monarch timeout does not work. The cause is that get_option() does parse a subsequent comma in the option string and signals that with a return value. So we don't need to check for a second comma ourselves. Signed-off-by: Xie XiuQi <xiexiuqi@huawei.com> Signed-off-by: Borislav Petkov <bp@suse.de> Cc: Andy Lutomirski <luto@amacapital.net> Cc: Borislav Petkov <bp@alien8.de> Cc: Brian Gerst <brgerst@gmail.com> Cc: Denys Vlasenko <dvlasenk@redhat.com> Cc: H. Peter Anvin <hpa@zytor.com> Cc: Linus Torvalds <torvalds@linux-foundation.org> Cc: Peter Zijlstra <peterz@infradead.org> Cc: Thomas Gleixner <tglx@linutronix.de> Cc: Tony Luck <tony.luck@intel.com> Link: http://lkml.kernel.org/r/1432120943-25028-1-git-send-email-xiexiuqi@huawei.com Link: http://lkml.kernel.org/r/1432628901-18044-19-git-send-email-bp@alien8.de Signed-off-by: Ingo Molnar <mingo@kernel.org>
Diffstat (limited to 'arch/x86/kernel/cpu')
-rw-r--r--arch/x86/kernel/cpu/mcheck/mce.c5
1 files changed, 1 insertions, 4 deletions
diff --git a/arch/x86/kernel/cpu/mcheck/mce.c b/arch/x86/kernel/cpu/mcheck/mce.c
index 521e5016aca6..0cbcd3183acf 100644
--- a/arch/x86/kernel/cpu/mcheck/mce.c
+++ b/arch/x86/kernel/cpu/mcheck/mce.c
@@ -2014,11 +2014,8 @@ static int __init mcheck_enable(char *str)
else if (!strcmp(str, "bios_cmci_threshold"))
cfg->bios_cmci_threshold = true;
else if (isdigit(str[0])) {
- get_option(&str, &(cfg->tolerant));
- if (*str == ',') {
- ++str;
+ if (get_option(&str, &cfg->tolerant) == 2)
get_option(&str, &(cfg->monarch_timeout));
- }
} else {
pr_info("mce argument %s ignored. Please use /sys\n", str);
return 0;
OpenPOWER on IntegriCloud