hwmon/aspeed-pwm-tacho: Return 0 RPM if fan disconnected / failed
Having a tachometer read return an -ETIMEDOUT error condition instead of 0 RPM due to a disconnected or failed fan is highly unexpected, and depending on higher level software can cause application failures. Return 0 RPM if tachometer cannot be read. This should trigger the same error paths in any sane fan control implementation without requiring special handling for the AST2x00 devices. Signed-off-by: Timothy Pearson <tpearson@raptorengineering.com>