summaryrefslogtreecommitdiffstats
path: root/Documentation/bus-virt-phys-mapping.txt
diff options
context:
space:
mode:
authorJack Morgenstein <jackm@mellanox.com>2012-01-26 16:41:33 +0200
committerRoland Dreier <roland@purestorage.com>2012-01-30 16:15:17 -0800
commita6f7feae6d19e84253918d88b04153af09d3a243 (patch)
tree8745df2fa8a944d81069249c88229b9e39c41b7d /Documentation/bus-virt-phys-mapping.txt
parentdcd6c92267155e70a94b3927bce681ce74b80d1f (diff)
downloadblackbird-obmc-linux-a6f7feae6d19e84253918d88b04153af09d3a243.tar.gz
blackbird-obmc-linux-a6f7feae6d19e84253918d88b04153af09d3a243.zip
IB/mlx4: pass SMP vendor-specific attribute MADs to firmware
In the current code, vendor-specific MADs (e.g with the FDR-10 attribute) are silently dropped by the driver, resulting in timeouts at the sending side and inability to query/configure the relevant feature. However, the ConnectX firmware is able to handle such MADs. For unsupported attributes, the firmware returns a GET_RESPONSE MAD containing an error status. For example, for a FDR-10 node with LID 11: # ibstat mlx4_0 1 CA: 'mlx4_0' Port 1: State: Active Physical state: LinkUp Rate: 40 (FDR10) Base lid: 11 LMC: 0 SM lid: 24 Capability mask: 0x02514868 Port GUID: 0x0002c903002e65d1 Link layer: InfiniBand Extended Port Query (EPI) vendor mad timeouts before the patch: # smpquery MEPI 11 -d ibwarn: [4196] smp_query_via: attr 0xff90 mod 0x0 route Lid 11 ibwarn: [4196] _do_madrpc: retry 1 (timeout 1000 ms) ibwarn: [4196] _do_madrpc: retry 2 (timeout 1000 ms) ibwarn: [4196] _do_madrpc: timeout after 3 retries, 3000 ms ibwarn: [4196] mad_rpc: _do_madrpc failed; dport (Lid 11) smpquery: iberror: [pid 4196] main: failed: operation EPI: ext port info query failed EPI query works OK with the patch: # smpquery MEPI 11 -d ibwarn: [6548] smp_query_via: attr 0xff90 mod 0x0 route Lid 11 ibwarn: [6548] mad_rpc: data offs 64 sz 64 mad data 0000 0000 0000 0001 0000 0001 0000 0001 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 # Ext Port info: Lid 11 port 0 StateChangeEnable:...............0x00 LinkSpeedSupported:..............0x01 LinkSpeedEnabled:................0x01 LinkSpeedActive:.................0x01 Signed-off-by: Jack Morgenstein <jackm@mellanox.com> Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Acked-by: Ira Weiny <weiny2@llnl.gov> Cc: <stable@vger.kernel.org> Signed-off-by: Roland Dreier <roland@purestorage.com>
Diffstat (limited to 'Documentation/bus-virt-phys-mapping.txt')
0 files changed, 0 insertions, 0 deletions
OpenPOWER on IntegriCloud