summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorSinan Kaya <okaya@codeaurora.org>2017-12-19 00:37:47 -0500
committerBjorn Helgaas <helgaas@kernel.org>2018-01-11 17:31:05 -0600
commitd5bf0f4f2bade2f26e2a170aecfc7c1a8feb5587 (patch)
treeed76eef08aee12ec471fe54079aa282a8c89145f
parent8c016394e838a48f4815d820d6589fe8da82fc9d (diff)
downloadblackbird-obmc-linux-d5bf0f4f2bade2f26e2a170aecfc7c1a8feb5587.tar.gz
blackbird-obmc-linux-d5bf0f4f2bade2f26e2a170aecfc7c1a8feb5587.zip
iommu/amd: Deprecate pci_get_bus_and_slot()
pci_get_bus_and_slot() is restrictive such that it assumes domain=0 as where a PCI device is present. This restricts the device drivers to be reused for other domain numbers. Getting ready to remove pci_get_bus_and_slot() function in favor of pci_get_domain_bus_and_slot(). Hard-code the domain number as 0 for the AMD IOMMU driver. Signed-off-by: Sinan Kaya <okaya@codeaurora.org> Signed-off-by: Bjorn Helgaas <helgaas@kernel.org> Reviewed-by: Gary R Hook <gary.hook@amd.com> Acked-by: Joerg Roedel <jroedel@suse.de>
-rw-r--r--drivers/iommu/amd_iommu.c3
-rw-r--r--drivers/iommu/amd_iommu_init.c9
-rw-r--r--drivers/iommu/amd_iommu_v2.c3
3 files changed, 9 insertions, 6 deletions
diff --git a/drivers/iommu/amd_iommu.c b/drivers/iommu/amd_iommu.c
index 7d5eb004091d..821547b23c65 100644
--- a/drivers/iommu/amd_iommu.c
+++ b/drivers/iommu/amd_iommu.c
@@ -527,7 +527,8 @@ static void amd_iommu_report_page_fault(u16 devid, u16 domain_id,
struct iommu_dev_data *dev_data = NULL;
struct pci_dev *pdev;
- pdev = pci_get_bus_and_slot(PCI_BUS_NUM(devid), devid & 0xff);
+ pdev = pci_get_domain_bus_and_slot(0, PCI_BUS_NUM(devid),
+ devid & 0xff);
if (pdev)
dev_data = get_dev_data(&pdev->dev);
diff --git a/drivers/iommu/amd_iommu_init.c b/drivers/iommu/amd_iommu_init.c
index 6fe2d0346073..4e4a615bf13f 100644
--- a/drivers/iommu/amd_iommu_init.c
+++ b/drivers/iommu/amd_iommu_init.c
@@ -1697,8 +1697,8 @@ static int iommu_init_pci(struct amd_iommu *iommu)
u32 range, misc, low, high;
int ret;
- iommu->dev = pci_get_bus_and_slot(PCI_BUS_NUM(iommu->devid),
- iommu->devid & 0xff);
+ iommu->dev = pci_get_domain_bus_and_slot(0, PCI_BUS_NUM(iommu->devid),
+ iommu->devid & 0xff);
if (!iommu->dev)
return -ENODEV;
@@ -1764,8 +1764,9 @@ static int iommu_init_pci(struct amd_iommu *iommu)
if (is_rd890_iommu(iommu->dev)) {
int i, j;
- iommu->root_pdev = pci_get_bus_and_slot(iommu->dev->bus->number,
- PCI_DEVFN(0, 0));
+ iommu->root_pdev =
+ pci_get_domain_bus_and_slot(0, iommu->dev->bus->number,
+ PCI_DEVFN(0, 0));
/*
* Some rd890 systems may not be fully reconfigured by the
diff --git a/drivers/iommu/amd_iommu_v2.c b/drivers/iommu/amd_iommu_v2.c
index 7d94e1d39e5e..8696382be837 100644
--- a/drivers/iommu/amd_iommu_v2.c
+++ b/drivers/iommu/amd_iommu_v2.c
@@ -564,7 +564,8 @@ static int ppr_notifier(struct notifier_block *nb, unsigned long e, void *data)
finish = (iommu_fault->tag >> 9) & 1;
devid = iommu_fault->device_id;
- pdev = pci_get_bus_and_slot(PCI_BUS_NUM(devid), devid & 0xff);
+ pdev = pci_get_domain_bus_and_slot(0, PCI_BUS_NUM(devid),
+ devid & 0xff);
if (!pdev)
return -ENODEV;
dev_data = get_dev_data(&pdev->dev);
OpenPOWER on IntegriCloud