summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorIan Campbell <ian.campbell@citrix.com>2010-08-23 11:59:29 +0100
committerIan Campbell <ian.campbell@citrix.com>2010-08-23 11:59:29 +0100
commit1dc7ce99b091a11cce0f34456c1ffcb928f17edd (patch)
treeb9f125fc324a86ff4af64fb0799d20330f61084c
parentc93a4dfb31f2c023da3ad1238c352452f2cc0e05 (diff)
downloadblackbird-obmc-linux-1dc7ce99b091a11cce0f34456c1ffcb928f17edd.tar.gz
blackbird-obmc-linux-1dc7ce99b091a11cce0f34456c1ffcb928f17edd.zip
xen: pvhvm: rename xen_emul_unplug=ignore to =unnnecessary
It is not immediately clear what this option causes to become ignored. The actual meaning is that it is not necessary to unplug the emulated devices to safely use the PV ones, even if the platform does not support the unplug protocol. (pressumably the user will only add this option if they have ensured that their domain configuration is safe). I think xen_emul_unplug=unnecessary better captures this. Signed-off-by: Ian Campbell <ian.campbell@citrix.com> Acked-by: Jeremy Fitzhardinge <jeremy.fitzhardinge@citrix.com> Acked-by: Stefano Stabellini <Stefano.Stabellini@eu.citrix.com>
-rw-r--r--Documentation/kernel-parameters.txt5
-rw-r--r--arch/x86/xen/platform-pci-unplug.c13
-rw-r--r--drivers/block/xen-blkfront.c2
-rw-r--r--include/xen/platform_pci.h2
4 files changed, 12 insertions, 10 deletions
diff --git a/Documentation/kernel-parameters.txt b/Documentation/kernel-parameters.txt
index 8bbe83b9d0b2..f084af0cb8e0 100644
--- a/Documentation/kernel-parameters.txt
+++ b/Documentation/kernel-parameters.txt
@@ -2629,8 +2629,9 @@ and is between 256 and 4096 characters. It is defined in the file
aux-ide-disks -- unplug non-primary-master IDE devices
nics -- unplug network devices
all -- unplug all emulated devices (NICs and IDE disks)
- ignore -- continue loading the Xen platform PCI driver even
- if the version check failed
+ unnecessary -- unplugging emulated devices is
+ unnecessary even if the host did not respond to
+ the unplug protocol
never -- do not unplug even if version check succeeds
xirc2ps_cs= [NET,PCMCIA]
diff --git a/arch/x86/xen/platform-pci-unplug.c b/arch/x86/xen/platform-pci-unplug.c
index 070dfa0654bd..0f456386cce5 100644
--- a/arch/x86/xen/platform-pci-unplug.c
+++ b/arch/x86/xen/platform-pci-unplug.c
@@ -78,10 +78,11 @@ void __init xen_unplug_emulated_devices(void)
/* check the version of the xen platform PCI device */
r = check_platform_magic();
/* If the version matches enable the Xen platform PCI driver.
- * Also enable the Xen platform PCI driver if the version is really old
- * and the user told us to ignore it. */
+ * Also enable the Xen platform PCI driver if the host does
+ * not support the unplug protocol (XEN_PLATFORM_ERR_MAGIC)
+ * but the user told us that unplugging is unnecessary. */
if (r && !(r == XEN_PLATFORM_ERR_MAGIC &&
- (xen_emul_unplug & XEN_UNPLUG_IGNORE)))
+ (xen_emul_unplug & XEN_UNPLUG_UNNECESSARY)))
return;
/* Set the default value of xen_emul_unplug depending on whether or
* not the Xen PV frontends and the Xen platform PCI driver have
@@ -102,7 +103,7 @@ void __init xen_unplug_emulated_devices(void)
}
}
/* Now unplug the emulated devices */
- if (!(xen_emul_unplug & XEN_UNPLUG_IGNORE))
+ if (!(xen_emul_unplug & XEN_UNPLUG_UNNECESSARY))
outw(xen_emul_unplug, XEN_IOPORT_UNPLUG);
xen_platform_pci_unplug = xen_emul_unplug;
}
@@ -128,8 +129,8 @@ static int __init parse_xen_emul_unplug(char *arg)
xen_emul_unplug |= XEN_UNPLUG_AUX_IDE_DISKS;
else if (!strncmp(p, "nics", l))
xen_emul_unplug |= XEN_UNPLUG_ALL_NICS;
- else if (!strncmp(p, "ignore", l))
- xen_emul_unplug |= XEN_UNPLUG_IGNORE;
+ else if (!strncmp(p, "unnecessary", l))
+ xen_emul_unplug |= XEN_UNPLUG_UNNECESSARY;
else if (!strncmp(p, "never", l))
xen_emul_unplug |= XEN_UNPLUG_NEVER;
else
diff --git a/drivers/block/xen-blkfront.c b/drivers/block/xen-blkfront.c
index ac1b682edecb..ab735a605cf3 100644
--- a/drivers/block/xen-blkfront.c
+++ b/drivers/block/xen-blkfront.c
@@ -834,7 +834,7 @@ static int blkfront_probe(struct xenbus_device *dev,
char *type;
int len;
/* no unplug has been done: do not hook devices != xen vbds */
- if (xen_platform_pci_unplug & XEN_UNPLUG_IGNORE) {
+ if (xen_platform_pci_unplug & XEN_UNPLUG_UNNECESSARY) {
int major;
if (!VDEV_IS_EXTENDED(vdevice))
diff --git a/include/xen/platform_pci.h b/include/xen/platform_pci.h
index 123b7752fa6a..590ccfd82645 100644
--- a/include/xen/platform_pci.h
+++ b/include/xen/platform_pci.h
@@ -20,7 +20,7 @@
#define XEN_UNPLUG_ALL_NICS 2
#define XEN_UNPLUG_AUX_IDE_DISKS 4
#define XEN_UNPLUG_ALL 7
-#define XEN_UNPLUG_IGNORE 8
+#define XEN_UNPLUG_UNNECESSARY 8
#define XEN_UNPLUG_NEVER 16
static inline int xen_must_unplug_nics(void) {
OpenPOWER on IntegriCloud