An HBRT error log larger than 4K sent to the host will be truncated
to 4K before it reaches HWSV, where a size mismatch prevents processing
of the log. To avoid this, truncate the HBRT log to 4K before sending
across interface to host.
Change-Id: Ic2c354da99c0a4ccec00ce58cf6ef34bc02e7996
CQ:SW480758
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/88724
Reviewed-by: Matt Derksen <mderkse1@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Roland Veloz <rveloz@us.ibm.com>
Reviewed-by: Daniel M Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
When HBRT first boots we read ATTR_HOSTSVC_PLID to set our starting
PLID/EID number. However, we never increment that attribute as we
create new logs. This will result in HBRT reusing PLIDs if it ever
reboots (e.g. after a crash or as part of a code update) and also
when it restarts after a mpipl.
Change-Id: I9f3b83f2be793908b62f3fb959fbbe590a4a1464
CQ: SW446539
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/66611
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Disable-CI: Christian R. Geddes <crgeddes@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
There was a bug in the runtime code where if a errorlog was created
and it had a deconfigure callout as well as a gard callout it would
attempt to create a gard record for the callout. This caused PNOR
reads which are not permitted in HBRT on systems with FSPs.
Change-Id: Ie2e1019889e0087396acfa07c7ce93e24643f322
CQ: SW430100
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/61505
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Add back in the lost 0x89 subsystem specifier to the HBRT
error logs.
Change-Id: Idf9a5a90e79137df3745e5a3d387255e5c87f715
CQ: SW420482
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55364
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
PRD needs to read the PNOR to tell OCC where to write in the pnor.
This will cache the PNOR section so PRD will not fail the
read call. If an error is created with pnor inaccessible,
errl manager could get stuck unless it was initialized first.
Change-Id: Ia7212bf99e947a1016423b37aff6f13ddfc7190a
CQ:SW412798
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54990
Reviewed-by: Martin Gloff <mgloff@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Reviewed-by: Roland Veloz <rveloz@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
CI-Ready: Daniel M. Crowell <dcrowell@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Need to avoid incrementing into the processor node
field of the PLID.
Decided to use the highest bit in the last 3 bytes as a dividing bit.
[0x##800000 - 0x##FFFFFF] -- for pre-boot setup errors.
[0x##000000 - 0x##7FFFFF] -- for post setup errors
When setting up from PNOR, we will look for the max EID in the post-setup range.
If no max is found, restart at 0.
Change-Id: I4a8811d9c93039090504ca9cf8c0eebc6812a4ca
CQ:SW416592
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54362
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
For every instance where a firmware_request is made, it is possible
to get an error if the FSP is doing a reset/reload. Now, if an
error returned from the firmware_request call indicates that the
FSP is doing a reset/reload, the firmware_request call will be made
again. Also refactored the code. Consolidated the calls to
firmware_request to another file to facilitate the adding/updating
of messages.
Change-Id: I5be440927ab255c55b40a0a0ed26f786d31a9317
RTC:182606
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/50505
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I6ce94d9cbf62fa7d2afe53b83b6bc5588a39a5d6
RTC:178947
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/45442
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I0c00eb1a400410a72cabb89d57d80e70d0ab3ebe
RTC: 131067
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/42657
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Reviewed-by: Martin Gloff <mgloff@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Corey V. Swenson <cswenson@us.ibm.com>
Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Attribute overrides are stored in a separate tank of memory from
the regular attribute values. This tank will be added as an
additional reserved memory section for HBRT to consume (only if
overrides exist).
Also fixed a couple bugs encountered while testing:
- No longer crashes if an error is created inside the targeting
initialization code.
- Added reserved bytes to RHB definition.
Change-Id: I5b10f7ad8dfcb58c550868bb83c4d843f48e1aae
RTC: 169942
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/38547
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Corey V. Swenson <cswenson@us.ibm.com>
Reviewed-by: Martin Gloff <mgloff@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I1ada7061d8fb258431b64c8e02bf84b019f7b25c
CQ: SW315645
Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/19661
Tested-by: Jenkins Server
Reviewed-by: WILLIAM G. HOFFA <wghoffa@us.ibm.com>
Tested-by: Jenkins OP Build CI
Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
. call errlmanager ack inline/synchronously, so that we don't have
dup eSELs due to shutdown
. don't resend sensor SEL events for errorlogs read out of PNOR
Depends-On: Ia2b211d8ebf489e92f2bc3d281d92175a6b61f30
Change-Id: I32c8e49ef2e00567987cdf030a225b61e7077cf6
CQ: SW312094
Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/19993
Tested-by: Jenkins Server
Tested-by: Jenkins OP Build CI
Tested-by: Jenkins OP HW
Tested-by: FSP CI Jenkins
Reviewed-by: WILLIAM G. HOFFA <wghoffa@us.ibm.com>
Reviewed-by: Richard J. Knight <rjknight@us.ibm.com>
Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: Ia2b211d8ebf489e92f2bc3d281d92175a6b61f30
Depends-On: I170d6586062b6e4684a55782df83a1b19ed7d937
Depends-On: Id8c44b0dcdb5714c163ac6485a53216786f9fbcf
Depends-On: I626bce5c8c0c8b7d0a44408280de178c7a86a83f
RTC: 123419
Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/18233
Tested-by: Jenkins Server
Tested-by: Jenkins OP Build CI
Reviewed-by: STEPHEN M. CPREK <smcprek@us.ibm.com>
Tested-by: Jenkins OP HW
Reviewed-by: WILLIAM G. HOFFA <wghoffa@us.ibm.com>
Tested-by: FSP CI Jenkins
Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
| |
-Fixed runtime resolution of the flag which determines if
an error log will be visable to the customer.
Change-Id: Id8c44b0dcdb5714c163ac6485a53216786f9fbcf
RTC:133158
Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/19658
Tested-by: Jenkins Server
Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I1bb13fede249ee09a65541cd04c6449b1bb555b2
RTC: 122885
Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/15712
Tested-by: Jenkins Server
Reviewed-by: Brian H. Horton <brianh@linux.ibm.com>
Reviewed-by: Corey V. Swenson <cswenson@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: Icf91982f1c590323df2c28afe7c6a3a38d8583ef
RTC:119076
Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/15276
Tested-by: Jenkins Server
Reviewed-by: STEPHEN M. CPREK <smcprek@us.ibm.com>
Reviewed-by: Brian H. Horton <brianh@linux.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
|
|
|
|
|
|
|
| |
Change-Id: I5664587b4f889099290ef50d50fa9ce5e580e1eb
Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/11167
Tested-by: Jenkins Server
Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I2903425c721c77354dd778a1a66fe9678ac40f2c
RTC: 106241
CQ: SW258964
Backport: release-fips810
Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/10769
Reviewed-by: Michael Baiocchi <baiocchi@us.ibm.com>
Tested-by: Jenkins Server
Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Partial updates for issues 94995 Errlm, 94996 targeting, 94998 istep/initservice
94999 VPD accessors, 95000 HWAS, and 95001 MDIA.
Open issues require additional research: push_back memory leak, sync_cond_wait
infinite loop, masterCpu uninitialized complaint, checkConstantsMatch template
no effect, and shutdown has no effect. Issue will be updated with progress.
Change-Id: If60fef67564a0c2cb2a10824100480095e896f17
RTC: 94995
Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/9492
Tested-by: Jenkins Server
Reviewed-by: MIKE J. JONES <mjjones@us.ibm.com>
Reviewed-by: STEPHEN M. CPREK <smcprek@us.ibm.com>
Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
|
|
RTC: 79415
Change-Id: I2fd60b48046425692fb3921b46ac21b57e1dba96
Reviewed-on: http://gfw160.austin.ibm.com:8080/gerrit/6349
Tested-by: Jenkins Server
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
|