* OpenPOWER support for native and compatibility mode for DD2.3Matt Derksen2019-02-281-15/+1
| | | | | | | | | | | | | | | | | | | | | | | Witherspoon (OpenPOWER) will run in native mode, which means all the processors have to be at the same level (all DD2.2 or all DD2.3). Other systems (ZZ) we support running in a mixed configuration where DD2.3 processors will be run in 2.2 compatibility mode. We also need to support arbitrary OP systems that might want to run in compatibility mode even without mixed parts. See src/usr/hwas/common/README.md for the rules and resulting mode. Change-Id: I80fb98e2687b945ba506f2d75b1533884443e10b RTC:201485 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/72214 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Move HOMER BAR to Secure Memory in SMF ModeIlya Smirnov2018-11-131-0/+14
| | | | | | | | | | | | | | | | | This commits enables HOMER BAR to point to the top of the secure memory on SMF-enabled systems. Consequently, the HOMER image and hostboot reserved memory will be moved to the secure memory if SMF is enabled. Change-Id: I37c7527b06688a41e57f14b4107ff53a507ffae8 RTC: 198825 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/66702 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* zero length dump on single node systemsRick Ward2018-04-051-1/+1
| | | | | | | | | | | | | | | Quick hack to fix dumps on single node systems. Proposed fix did not work. This change forces isCurrentMasterNode() to always return true. Change-Id: I9366617d42923e5d13c0f7ea4f624e1749ad6810 CQ:SW423016 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56769 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Setup Node-Level Attributes for Multinode TCE SupportMike Baiocchi2018-03-261-0/+28
| | | | | | | | | | | | | | | | | | | | | This commit establishes a TCE Table and allocates the necessary TCEs for each node in a multinode (ie, Fleetwood) system. It then sets the corresponding node-level TCE attributes such that the FSP can use these TCEs for PSI Diagnostics and DMAing-via-TCEs the PAYLOAD and HDAT content. Change-Id: Ibd06675ea68a9c630987765b51fdd9db631f6425 RTC:187335 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56129 CI-Ready: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Dump collection should only be run on the master node and skipped on slaves.Rick Ward2018-03-221-1/+15
| | | | | | | | | | | | | | | | | | | Added an attribute, IS_MASTER_DRAWER, and a utility function, isCurrentMasterNode(). The attribute is set in host_sys_fab_iovalid_processing which is called during istep 18.9. isCurrentMasterNode() is called by call_host_mpipl_service() to ensure that memory dump collection is only performed on the master node during a MPIPL. Change-Id: I7fd48476c3cd7cf4697eafed6705d158a9c54dcf RTC: 116089 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55162 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Replaced calls to bmc for sensor type with static information.Donald Washburn2017-06-271-1/+1
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | The sendErrLogToBMC function was calling to the bmc in order to determine the type of a sensor based upon a sensor number. It was determined that the sensor type can be obtained from the sensor number by data loaded during initialization via the TARGETING namespace. The ipmi call from SenorBase::getSensorType was removed from the sendErrLogToBMC function and replaced with a call to IpmiConfigLookup::getSensorType. The getSensorType function from the new IpmiConfigLookup class retrieves sensor data from target attributes and as such does not call the bmc for the type information. * Added the new IpmiConfigLookup class in the IPMI namespace. This class provides static methods to retrive sensor data provided by the IPMI_SENSOR target attribute. In addition to sensor type, the sensor entity id and sensor name can be obtined from this class based upon a sensor number. * Changed sendErrLogToBMC to call IpmiConfigLookup::getSensorType instead of Sensor::SensorBase::getSensorInfo. RTC: 164493 Change-Id: Ie8e7fa5c37fa972d6cecd1e4b69e2d0cb7504533 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/42128 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Richard J. Knight <rjknight@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Update to use uint32_t sensor numbersRichard J. Knight2015-02-191-3/+52
| | | | | | | | | | | | | | | | -Add frequency sensor type/numbers -Add getTargetFromSensor interface -Fix missing gaps in DIMM Temp sensor range -Add Centaur Temp sensors -Move getSensorNumber to targeting Change-Id: Id788a60b4dc0171402817408e8c6d6dcd637048c RTC:123523 Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/15653 Tested-by: Jenkins Server Reviewed-by: Brian Silver <bsilver@us.ibm.com> Reviewed-by: Brian H. Horton <brianh@linux.ibm.com> Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
* Change copyright prolog for all files to Apache.Patrick Williams2014-05-211-11/+11
| | | | | | | Change-Id: I5664587b4f889099290ef50d50fa9ce5e580e1eb Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/11167 Tested-by: Jenkins Server Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
* Support multinode targetingNick Bofferding2013-10-081-0/+255
- Added support for master processor type attributes - Made attribute sync multinode aware - Added platform properties constants - Added multinode iterator support - Extended default iterator to skip hidden system targets - Added raw iterator to "see" hidden system targets - Updated target service to be multinode aware - Added new API to query master proc per node - Modified MRW parser to support cross node peers - Modified MRW parser to default master proc per node - Removed cross node peer workarounds in node splitter script - Added common support for master system targets - Updated attribute compiler to serialize cross node peer targets - Updated attribute compiler to generate attribute size map - Updated attribute compiler to impose special ordering on target layout - Inhibited XML merge script from merging itself in xmltohb makefile - Inhibited duplicate weak symbol errors in trace statements Change-Id: I661eca12f3a7cc16c0ff5476a7ae66cea3bad7d3 RTC: 63940 Reviewed-on: http://gfw160.austin.ibm.com:8080/gerrit/6103 Tested-by: Jenkins Server Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>