summaryrefslogtreecommitdiffstats
path: root/src/test/testcases/testExecutorCntrlTimer.py
blob: fae474d7df2eb472c8a510c681c5e3f92a433a74 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
#!/usr/bin/python
# IBM_PROLOG_BEGIN_TAG
# This is an automatically generated prolog.
#
# $Source: src/test/testcases/testExecutorCntrlTimer.py $
#
# OpenPOWER sbe Project
#
# Contributors Listed Below - COPYRIGHT 2016,2018
# [+] International Business Machines Corp.
#
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
#     http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or
# implied. See the License for the specific language governing
# permissions and limitations under the License.
#
# IBM_PROLOG_END_TAG
import testPSUUtil
import testRegistry as reg
import testUtil

#-------------------------------
# This  is a Test Expected Data
#-------------------------------
'''
This data are the values or strings that needs to be validated for the test.
'''
'''
#------------------------------------------------------------------------------------------------------------------------------
# SBE side test data - 32000us timer
#------------------------------------------------------------------------------------------------------------------------------
'''
sbe_test_startTimer = (
    #-----------------------------------------------------------------------------------------------------
    #   OP      Reg                               ValueToWrite         size    Test Expected Data       Description
    #-----------------------------------------------------------------------------------------------------
    ["write", reg.REG_MBOX0, "0000010100F0D401", 	 8, 	"None", 		"Writing to MBOX0 address"],
    ["write", reg.REG_MBOX1, "0000000000007D00", 	 8, 	"None", 			"Writing to MBOX1 address"],
    ["write", reg.PSU_SBE_DOORBELL_REG_WO_OR, "8000000000000000", 	 8, 	"None", 		"Update SBE Doorbell register to interrupt SBE"],
    )
'''
#------------------------------------------------------------------------------------------------------------------------------
# SBE side test data - Stop Timer.
# In this test case though timer is already expired, we want to check that
# stop timer does not fail in that case
#------------------------------------------------------------------------------------------------------------------------------
'''
sbe_test_StopTimer = (
    #-----------------------------------------------------------------------------------------------------
    #   OP      Reg                               ValueToWrite         size    Test Expected Data       Description
    #-----------------------------------------------------------------------------------------------------
    ["write", reg.REG_MBOX0, "0000010200F0D401", 	 8, 	"None", 		"Writing to MBOX0 address"],
    ["write", reg.PSU_SBE_DOORBELL_REG_WO_OR, "8000000000000000", 	 8, 	"None", 		"Update SBE Doorbell register to interrupt SBE"],
    )
'''
#---------------------
# Host side test data - SUCCESS
#---------------------
'''
host_test_Timer_Cmd_success = (
    #----------------------------------------------------------------------------------------------------------------
    #   OP     Reg                                 ValueToWrite        size    Test Expected Data        Description
    #----------------------------------------------------------------------------------------------------------------
    ["read", reg.REG_MBOX4, 		"0", 	 	 8, 	"0000000000F0D401", "Reading Host MBOX4 data to Validate"],
    )
'''
#-----------------------------------------------------------------------
# Do not modify - Used to simulate interrupt on Ringing Doorbell on Host
#-----------------------------------------------------------------------
'''
host_polling_data = (
    #----------------------------------------------------------------------------------------------------------------
    #   OP     Reg                                 ValueToWrite        size    Test Expected Data           Description
    #----------------------------------------------------------------------------------------------------------------
    ["read", reg.PSU_HOST_DOORBELL_REG_WO_OR, 		"0", 		8, 	"8000000000000000", "Reading Host Doorbell for Interrupt"],
    )

timer_polling_data = (
    #----------------------------------------------------------------------------------------------------------------
    #   OP     Reg                                 ValueToWrite        size    Test Expected Data           Description
    #----------------------------------------------------------------------------------------------------------------
    ["read", reg.PSU_HOST_DOORBELL_REG_WO_OR, 		"0", 		8, 	"0002000000000000", "Reading Host Doorbell for Interrupt"],
    )

#-------------------------
# Main Function
#-------------------------
def main():
    # Run Simics initially
    testUtil.runCycles( 10000000 );

    # Intialize the class obj instances
    regObj = testPSUUtil.registry() # Registry obj def for operation

    print "\n  Execute SBE Test set1  [ PutCntrlTimer ] ...\n"

    '''
    Test Case 1
    '''
    print "\n  Test Start timer\n"
    # HOST->SBE data set execution
    regObj.ExecuteTestOp( testPSUUtil.simSbeObj, sbe_test_startTimer )

    #Poll on HOST DoorBell Register for interrupt
    regObj.pollingOn( testPSUUtil.simSbeObj, host_polling_data, 5 )

    #SBE->HOST data set execution
    regObj.ExecuteTestOp( testPSUUtil.simSbeObj, host_test_Timer_Cmd_success )

    #Poll on HOST DoorBell Register for interrupt
    print "\n  Poll on Host side for Timer INTR  ...\n"
    regObj.pollingOn( testPSUUtil.simSbeObj, timer_polling_data, 50 )

    '''
    Test Case 2. Stop timer when timer already expired
    '''
    print "\n  Test Stop timer\n"
    # HOST->SBE data set execution
    regObj.ExecuteTestOp( testPSUUtil.simSbeObj, sbe_test_StopTimer )

    #Poll on HOST DoorBell Register for interrupt
    regObj.pollingOn( testPSUUtil.simSbeObj, host_polling_data, 5 )

    #SBE->HOST data set execution
    regObj.ExecuteTestOp( testPSUUtil.simSbeObj, host_test_Timer_Cmd_success )


if __name__ == "__main__":
    main()
    if err:
    	print ( "\nTest Suite completed with error(s)" )
    	#sys.exit(1)
    else:
    	print ( "\nTest Suite completed with no errors" )