summaryrefslogtreecommitdiffstats
path: root/src/import/chips/p9/procedures/xml/error_info/p9_common_poweronoff_errors.xml
blob: b87937afa55b9c6cb3a377c3a8584984704ecc82 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
<!-- IBM_PROLOG_BEGIN_TAG                                                   -->
<!-- This is an automatically generated prolog.                             -->
<!--                                                                        -->
<!-- $Source: import/chips/p9/procedures/xml/error_info/p9_common_poweronoff_errors.xml $ -->
<!--                                                                        -->
<!-- OpenPOWER sbe Project                                                  -->
<!--                                                                        -->
<!-- Contributors Listed Below - COPYRIGHT 2015,2016                        -->
<!-- [+] International Business Machines Corp.                              -->
<!--                                                                        -->
<!--                                                                        -->
<!-- Licensed under the Apache License, Version 2.0 (the "License");        -->
<!-- you may not use this file except in compliance with the License.       -->
<!-- You may obtain a copy of the License at                                -->
<!--                                                                        -->
<!--     http://www.apache.org/licenses/LICENSE-2.0                         -->
<!--                                                                        -->
<!-- Unless required by applicable law or agreed to in writing, software    -->
<!-- distributed under the License is distributed on an "AS IS" BASIS,      -->
<!-- WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or        -->
<!-- implied. See the License for the specific language governing           -->
<!-- permissions and limitations under the License.                         -->
<!--                                                                        -->
<!-- IBM_PROLOG_END_TAG                                                     -->
<!-- Error definitions for p9_pfet_init and p9_pfet_lib procedures -->
<hwpErrors>
  <!-- ********************************************************************* -->
  <hwpError>
    <sbeError/>
    <rc>RC_PMPROC_PFETLIB_BAD_DOMAIN</rc>
    <description>Invalid domain value passed to p9_pfet_control.</description>
    <ffdc>EX</ffdc>
    <ffdc>DOMAIN</ffdc>
    <callout>
      <procedure>CODE</procedure>
      <priority>HIGH</priority>
    </callout>
  </hwpError>
  <!-- ********************************************************************* -->
  <hwpError>
    <sbeError/>
    <rc>RC_PMPROC_PFETLIB_BAD_SCOM</rc>
    <description>SCOM request failed.</description>
    <ffdc>EX</ffdc>
    <ffdc>DOMAIN</ffdc>
    <ffdc>ADDRESS</ffdc>
    <callout>
      <procedure>CODE</procedure>
      <priority>HIGH</priority>
    </callout>
  </hwpError>
  <!-- ********************************************************************* -->
  <hwpError>
    <sbeError/>
    <rc>RC_PMPROC_PFETLIB_BAD_OP</rc>
    <description>Invalid operation value passed to p9_pfet_control.</description>
    <ffdc>EX</ffdc>
    <ffdc>DOMAIN</ffdc>
    <ffdc>OPERATION</ffdc>
    <callout>
      <procedure>CODE</procedure>
      <priority>HIGH</priority>
    </callout>
  </hwpError>
  <!-- ********************************************************************* -->
  <hwpError>
    <sbeError/>
    <rc>RC_PMPROC_PFETLIB_RAIL_ON</rc>
    <description>Error returned turning PFETs on in p9_pfet_control.</description>
    <ffdc>EX</ffdc>
    <ffdc>DOMAIN</ffdc>
    <ffdc>OPERATION</ffdc>
  </hwpError>
  <!-- ********************************************************************* -->
  <hwpError>
    <sbeError/>
    <rc>RC_PMPROC_PFETLIB_RAIL_OFF</rc>
    <description>Error returned turning PFETs off in p9_pfet_control.</description>
    <ffdc>EX</ffdc>
    <ffdc>DOMAIN</ffdc>
    <ffdc>OPERATION</ffdc>
  </hwpError>
  <!-- ********************************************************************* -->
  <hwpError>
    <sbeError/>
    <rc>RC_PMPROC_PFETLIB_TIMEOUT</rc>
    <description>
        PFET sequencer timed out in p9_pfet_control.
        Bad EX Chiplet
    </description>
    <ffdc>ADDRESS</ffdc>
    <ffdc>PFETCONTROLVALUE</ffdc>
    <ffdc>DOMAIN</ffdc>
    <callout>
      <childTargets>
        <parent>PROC_CHIP_IN_ERROR</parent>
        <childType>TARGET_TYPE_EX_CHIPLET</childType>
        <childNumber>EX_NUMBER_IN_ERROR</childNumber>
      </childTargets>
      <priority>HIGH</priority>
    </callout>
    <deconfigure>
      <childTargets>
        <parent>PROC_CHIP_IN_ERROR</parent>
        <childType>TARGET_TYPE_EX_CHIPLET</childType>
        <childNumber>EX_NUMBER_IN_ERROR</childNumber>
      </childTargets>
    </deconfigure>
    <gard>
      <childTargets>
        <parent>PROC_CHIP_IN_ERROR</parent>
        <childType>TARGET_TYPE_EX_CHIPLET</childType>
        <childNumber>EX_NUMBER_IN_ERROR</childNumber>
      </childTargets>
    </gard>
  </hwpError>
  <!-- ********************************************************************* -->
  <hwpError>
    <sbeError/>
    <rc>RC_PMPROC_PFET_CODE_BAD_MODE</rc>
    <description>Unknown mode passed to p9_pfet_init</description>
    <ffdc>EX</ffdc>
    <ffdc>DOMAIN</ffdc>
    <callout>
      <procedure>CODE</procedure>
      <priority>HIGH</priority>
    </callout>
  </hwpError>
  <!-- ********************************************************************* -->
  <hwpError>
    <sbeError/>
    <rc>RC_PMPROC_PFET_GET_ATTR</rc>
    <description>p9_pfet_init could not get an attribute.</description>   
    <ffdc>EX</ffdc>
    <ffdc>DOMAIN</ffdc>
    <ffdc>OPERATION</ffdc>
  </hwpError>
  <!-- ********************************************************************* -->
</hwpErrors>