<!-- IBM_PROLOG_BEGIN_TAG -->
<!-- This is an automatically generated prolog. -->
<!-- -->
<!-- $Source: src/import/chips/ocmb/explorer/procedures/xml/error_info/exp_i2c_scom_errors.xml $ -->
<!-- -->
<!-- OpenPOWER sbe Project -->
<!-- -->
<!-- Contributors Listed Below - COPYRIGHT 2018,2019 -->
<!-- [+] International Business Machines Corp. -->
<!-- -->
<!-- -->
<!-- Licensed under the Apache License, Version 2.0 (the "License"); -->
<!-- you may not use this file except in compliance with the License. -->
<!-- You may obtain a copy of the License at -->
<!-- -->
<!-- http://www.apache.org/licenses/LICENSE-2.0 -->
<!-- -->
<!-- Unless required by applicable law or agreed to in writing, software -->
<!-- distributed under the License is distributed on an "AS IS" BASIS, -->
<!-- WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or -->
<!-- implied. See the License for the specific language governing -->
<!-- permissions and limitations under the License. -->
<!-- -->
<!-- IBM_PROLOG_END_TAG -->
<hwpErrors>
<hwpError>
<rc>RC_I2C_GET_SCOM_INVALID_READ_SIZE</rc>
<description>
First Byte data returned from the i2c register read contains
the size of the remaining bytes returned. This should match
the number of bytes we requested.
</description>
<ffdc>TARGET</ffdc>
<ffdc>ADDRESS</ffdc>
<ffdc>SIZE_RETURNED</ffdc>
<ffdc>SIZE_REQUESTED</ffdc>
</hwpError>
<hwpError>
<rc>RC_I2C_SCOM_EXPECTED_IBM_INDICATOR</rc>
<description>
First Byte of the address passed to i2c_scom operation did not match
what was required for IBM scom. I2c scoms associated with 64 bits of
are assumed to be IBM scoms and must have 0x08 set in the first byte
of the address.
</description>
<ffdc>TARGET</ffdc>
<ffdc>ADDRESS</ffdc>
</hwpError>
<hwpError>
<rc>RC_I2C_SCOM_UNEXPECTED_IBM_INDICATOR</rc>
<description>
First Byte of the address passed to i2c_scom operation had 0x08 set which
indicates IBM scom. But the data associated with the address does not
match IBM scom data size.
</description>
<ffdc>TARGET</ffdc>
<ffdc>ADDRESS</ffdc>
</hwpError>
</hwpErrors>
|