Validate OBUS DL lane failed indications during initial link training
Under certain circumstances, the DL logic can consume a spare lane during training, reporting that the link trained successfully but without reporting a lane sparing event in the FIR This commit adds a change to check for failed lanes in this case, and: - raise the lane spared indication in the FIR if a single lane is spared (no HWP error returned, but attention can trigger MFG IPL failure) - mark the link as failed to train if more than a single lane is marked spared, to trigger reconfig loop Change-Id: Iecc69bb1cad172d9c0b16c9b987cc6896e46216b CQ: SW439577 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/63383 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: HWSV CI <hwsv-ci+hostboot@us.ibm.com> Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com> Tested-by: PPE CI <ppe-ci+hostboot@us.ibm.com> Reviewed-by: DANIEL C. HOWE <dchowe@us.ibm.com> Reviewed-by: Megan P. Nguyen <pmegan@us.ibm.com> Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com> Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/63394 Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com>
Diffstat (limited to 'src/sbefw/app/power')
0 files changed, 0 insertions, 0 deletions
OpenPOWER on IntegriCloud