| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
|
|
|
|
| |
A quick fix to ensure that mbox-reload.service has a chance to run
after the power off and before the power on during a reboot.
An upcoming refactoring will remove the need for this patch.
Change-Id: Ieee0573e9bd4dec518361da9244d95a27357abd3
Signed-off-by: Matt Spinler <spinler@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
| |
Romulus VDDR uses different regulator, so the scripts is updated:
1. Remove VDDR related settings in vrm-control.sh
2. Add vrm.sh to invoke vrm-control.sh to set VDN, and invoke i2cset to
set VDDR.
Change-Id: I8be757728833280392328eaf03b3a88b911a4fbd
Signed-off-by: Lei YU <mine260309@gmail.com>
|
|
|
|
|
|
|
|
|
|
| |
Add AVSBus and VRM control scripts.
Add systemd services to do AVSBus workaround, disable AVSBus, do VRM workaround and enable
AVSBus.
Add BitBake recipe to install script and services.
Change-Id: I72ec0138d23eba57ee56d5a6b01e3cd638c819bc
Signed-off-by: Lei YU <mine260309@gmail.com>
|
|
Romulus power on scripts requires a workaround to trigger CPLD to give
pgood signal after vcs_workaround.
Add this as cpld_trigger service that runs after vcs_workaround and
before obmc-host-start-pre.
Change-Id: I0723bad38a5832f0bb2a8776129885308a8e644a
Signed-off-by: Lei YU <mine260309@gmail.com>
|