summaryrefslogtreecommitdiffstats
path: root/drivers/clocksource/samsung_pwm_timer.c
Commit message (Collapse)AuthorAgeFilesLines
* clocksource: misc drivers: Remove deprecated IRQF_DISABLEDMichael Opdenacker2013-12-111-1/+1
| | | | | | | | | | | This patch removes the use of the IRQF_DISABLED flag It's a NOOP since 2.6.35 and it will be removed one day. [dlezcano] : slightly changed the changelog Signed-off-by: Michael Opdenacker <michael.opdenacker@free-electrons.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
* Merge remote-tracking branch 'tip/timers/core' into ↵John Stultz2013-09-261-53/+67
|\ | | | | | | | | | | | | | | | | | | | | fordlezcano/3.13/sched-clock64-conversion Update to tip/timers/core and resolve minor conflict. Conflicts: drivers/clocksource/samsung_pwm_timer.c Signed-off-by: John Stultz <john.stultz@linaro.org>
| * Merge tag 'clk-for-linus-3.12' of git://git.linaro.org/people/mturquette/linuxLinus Torvalds2013-09-091-4/+8
| |\ | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Pull clock framework changes from Michael Turquette: "The common clk framework changes for 3.12 are dominated by clock driver patches, both new drivers and fixes to existing. A high percentage of these are for Samsung platforms like Exynos. Core framework fixes and some new features like automagical clock re-parenting round out the patches" * tag 'clk-for-linus-3.12' of git://git.linaro.org/people/mturquette/linux: (102 commits) clk: only call get_parent if there is one clk: samsung: exynos5250: Simplify registration of PLL rate tables clk: samsung: exynos4: Register PLL rate tables for Exynos4x12 clk: samsung: exynos4: Register PLL rate tables for Exynos4210 clk: samsung: exynos4: Reorder registration of mout_vpllsrc clk: samsung: pll: Add support for rate configuration of PLL46xx clk: samsung: pll: Use new registration method for PLL46xx clk: samsung: pll: Add support for rate configuration of PLL45xx clk: samsung: pll: Use new registration method for PLL45xx clk: samsung: exynos4: Rename exynos4_plls to exynos4x12_plls clk: samsung: exynos4: Remove checks for DT node clk: samsung: exynos4: Remove unused static clkdev aliases clk: samsung: Modify _get_rate() helper to use __clk_lookup() clk: samsung: exynos4: Use separate aliases for cpufreq related clocks clocksource: samsung_pwm_timer: Get clock from device tree ARM: dts: exynos4: Specify PWM clocks in PWM node pwm: samsung: Update DT bindings documentation to cover clocks clk: Move symbol export to proper location clk: fix new_parent dereference before null check clk: wm831x: Initialise wm831x pointer on init ...
| | * clocksource: samsung_pwm_timer: Get clock from device treeTomasz Figa2013-09-061-4/+8
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | When booting with device tree static clkdev aliases should not be used. This patch modifies the samsung_pwm_timer driver to use DT-based clock lookup when booting with device tree. Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com> Signed-off-by: Mike Turquette <mturquette@linaro.org>
| * | clocksource: samsung_pwm_timer: Handle suspend/resume correctlyTomasz Figa2013-08-061-14/+28
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Current suspend/resume handling of the driver was broken, because: - periodic timer was being enabled in CLOCK_EVT_MODE_RESUME mode, which does not seem to be correct behavior looking at other platforms, - PWM divisors need to be restored, but they were not, - clockevent interrupt mask needs to be restored, but it was not, - clocksource was being restored in clockevent resume callback. This patch fixes issues mentioned above, making suspend/resume handling in the driver correct. Signed-off-by: Tomasz Figa <tomasz.figa@gmail.com> Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com> Tested-by: Heiko Stuebner <heiko@sntech.de> Tested-by: Mark Brown <broonie@linaro.org> Tested-by: Sylwester Nawrocki <sylvester.nawrocki@gmail.com> Acked-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org>
| * | clocksource: samsung_pwm_timer: Do not use clocksource_mmioTomasz Figa2013-08-061-4/+15
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | In case of Samsung PWM timer, clocksource MMIO can not be used, because custom suspend/resume callbacks are required. Signed-off-by: Tomasz Figa <tomasz.figa@gmail.com> Reviewed-by: Daniel Lezcano <daniel.lezcano@linaro.org> Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com> Tested-by: Heiko Stuebner <heiko@sntech.de> Tested-by: Mark Brown <broonie@linaro.org> Tested-by: Sylwester Nawrocki <sylvester.nawrocki@gmail.com> Acked-by: Arnd Bergmann <arnd@arndb.de>
| * | clocksource: samsung_pwm_timer: Cache clocksource register addressTomasz Figa2013-08-061-25/+8
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Instead of calculating register every time the timer should be read, we can just do it one time at initialization and store the address in driver data. Signed-off-by: Tomasz Figa <tomasz.figa@gmail.com> Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com> Tested-by: Heiko Stuebner <heiko@sntech.de> Tested-by: Mark Brown <broonie@linaro.org> Tested-by: Sylwester Nawrocki <sylvester.nawrocki@gmail.com> Acked-by: Arnd Bergmann <arnd@arndb.de>
| * | clocksource: samsung_pwm_timer: Correct definition of AUTORELOAD bitTomasz Figa2013-08-061-1/+12
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | PWM channel 4 has its autoreload bit located at different position. This patch fixes the driver to account for that. This fixes a problem with the clocksource hanging after it overflows because it is not reloaded any more. Signed-off-by: Tomasz Figa <tomasz.figa@gmail.com> Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com> Tested-by: Heiko Stuebner <heiko@sntech.de> Tested-by: Mark Brown <broonie@linaro.org> Tested-by: Sylwester Nawrocki <sylvester.nawrocki@gmail.com> Acked-by: Arnd Bergmann <arnd@arndb.de>
| * | clocksource: samsung_pwm_timer: Do not request PWM mem regionTomasz Figa2013-08-061-10/+1
| |/ | | | | | | | | | | | | | | | | | | | | | | PWM registers are shared between clocksource and PWM drivers and so can not be claimed for exclusive use. Signed-off-by: Tomasz Figa <tomasz.figa@gmail.com> Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com> Tested-by: Heiko Stuebner <heiko@sntech.de> Tested-by: Mark Brown <broonie@linaro.org> Tested-by: Sylwester Nawrocki <sylvester.nawrocki@gmail.com> Acked-by: Arnd Bergmann <arnd@arndb.de>
* | clocksource: samsung_pwm_timer: Switch to sched_clock_register()Stephen Boyd2013-07-301-2/+2
|/ | | | | | | | | | | | The 32 bit sched_clock interface now supports 64 bits. Upgrade to the 64 bit function to allow us to remove the 32 bit registration interface. Cc: Tomasz Figa <t.figa@samsung.com> Cc: Kyungmin Park <kyungmin.park@samsung.com> Cc: Kukjin Kim <kgene.kim@samsung.com> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org> Signed-off-by: John Stultz <john.stultz@linaro.org>
* sched_clock: Make ARM's sched_clock generic for all architecturesStephen Boyd2013-06-121-1/+1
| | | | | | | | | | Nothing about the sched_clock implementation in the ARM port is specific to the architecture. Generalize the code so that other architectures can use it by selecting GENERIC_SCHED_CLOCK. Signed-off-by: Stephen Boyd <sboyd@codeaurora.org> [jstultz: Merge minor collisions with other patches in my tree] Signed-off-by: John Stultz <john.stultz@linaro.org>
* clocksource: samsung_pwm_timer: Work around rounding errors in clockevents coreTomasz Figa2013-04-281-0/+13
| | | | | | | | | | | | | | | Due to rounding errors in clockevents core (in conversions between ticks and nsecs), it might happen that the set_next_event callback gets called with cycles = 0, causing the code to incorrectly program the PWM timer. This patch modifies the callback to program the timer for 1 tick, if received tick count value is 0. Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Kukjin Kim <kgene.kim@samsung.com> Signed-off-by: Olof Johansson <olof@lixom.net>
* clocksource: samsung_pwm_timer: Correct programming of clock eventsTomasz Figa2013-04-281-4/+2
| | | | | | | | | | | | | | | | | | In current code, the tick count value programmed to the hardware is always decremented by one. This is reasonable for periodic mode, since there is one extra tick between 0 and COUNT (after reloading), but it makes oneshot events happen 1 tick earlier than requested, because the interrupt is triggered on transition from 1 to 0. This patch removes the decrementation from PWM channel setup code and moves it instead to periodic timer setup, to make both periodic and oneshot modes work correctly. Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Kukjin Kim <kgene.kim@samsung.com> Signed-off-by: Olof Johansson <olof@lixom.net>
* clocksource: samsung_pwm_timer: Use proper clockevents max_deltaTomasz Figa2013-04-281-1/+2
| | | | | | | | | | | | | | This patch replaces hardcoded -1 argument passed to clockevents_config_and_register() with tcnt_max calculated based on variant data. This fixes invalid max delta configuration for 16-bit timers of s3c24xx. Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Kukjin Kim <kgene.kim@samsung.com> Signed-off-by: Olof Johansson <olof@lixom.net>
* clocksource: samsung_pwm_timer: Add support for non-DT platformsTomasz Figa2013-04-281-2/+14
| | | | | | | | | | | | This patch extends the driver to support platforms that still use legacy ATAGS-based boot, without device tree, by providing an exported function that can be used from platform code to initialize the clocksource. Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Kukjin Kim <kgene.kim@samsung.com> Signed-off-by: Olof Johansson <olof@lixom.net>
* clocksource: samsung_pwm_timer: Keep all driver data in a structureTomasz Figa2013-04-281-83/+74
| | | | | | | | | | | This patch modifies the driver to keep all its private data consistently in a single struct, instead of keeping part as separate variables. Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Kukjin Kim <kgene.kim@samsung.com> Signed-off-by: Olof Johansson <olof@lixom.net>
* clocksource: samsung_pwm_timer: Make PWM spinlock globalTomasz Figa2013-04-281-11/+13
| | | | | | | | | | | | This patch makes the PWM spinlock global and exports it to allow using it in Samsung PWM driver (will be reworked to use proper synchronization in further patches). Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Kukjin Kim <kgene.kim@samsung.com> Signed-off-by: Olof Johansson <olof@lixom.net>
* clocksource: add samsung pwm timer driverTomasz Figa2013-04-211-0/+477
This adds a new clocksource driver for the PWM timer that is present in most Samsung SoCs, based on the existing driver in arch/arm/plat-samsung/samsung-time.c and many changes implemented by Tomasz Figa. Originally, the conversion of all Samsung machines to the new driver was planned for 3.10, but that work ended up being too late and too invasive just before the merge window. Unfortunately, other changes in the Exynos platform resulted in some Exynos4 setups, particularly the Universal C210 board to be broken. In order to fix that with minimum risk, so we now leave the existing pwm clocksource driver in place for all older platforms and use the new driver only for device tree enabled boards. This way, we can get the broken machines running again using DT descriptions. All clocksource changes were implemented by Tomasz, while the DT registration was rewritten by Arnd. Signed-off-by: Arnd Bergmann <arnd@arndb.de> Cc: Tomasz Figa <t.figa@samsung.com> Cc: Kyungmin Park <kyungmin.park@samsung.com> Cc: Kukjin Kim <kgene.kim@samsung.com> Cc: Ben Dooks <ben-linux@fluff.org> Cc: John Stultz <john.stultz@linaro.org> Cc: Thomas Gleixner <tglx@linutronix.de>
OpenPOWER on IntegriCloud