summaryrefslogtreecommitdiffstats
path: root/drivers/pci/quirks.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/pci/quirks.c')
-rw-r--r--drivers/pci/quirks.c57
1 files changed, 57 insertions, 0 deletions
diff --git a/drivers/pci/quirks.c b/drivers/pci/quirks.c
index dc2ee0de3c6b..eb57d8b610fe 100644
--- a/drivers/pci/quirks.c
+++ b/drivers/pci/quirks.c
@@ -460,6 +460,7 @@ static void quirk_nfp6000(struct pci_dev *dev)
}
DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_NETRONOME, PCI_DEVICE_ID_NETRONOME_NFP4000, quirk_nfp6000);
DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_NETRONOME, PCI_DEVICE_ID_NETRONOME_NFP6000, quirk_nfp6000);
+DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_NETRONOME, PCI_DEVICE_ID_NETRONOME_NFP5000, quirk_nfp6000);
DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_NETRONOME, PCI_DEVICE_ID_NETRONOME_NFP6000_VF, quirk_nfp6000);
/* On IBM Crocodile ipr SAS adapters, expand BAR to system page size */
@@ -2105,6 +2106,7 @@ static void quirk_netmos(struct pci_dev *dev)
if (dev->subsystem_vendor == PCI_VENDOR_ID_IBM &&
dev->subsystem_device == 0x0299)
return;
+ /* else: fall through */
case PCI_DEVICE_ID_NETMOS_9735:
case PCI_DEVICE_ID_NETMOS_9745:
case PCI_DEVICE_ID_NETMOS_9845:
@@ -4805,3 +4807,58 @@ DECLARE_PCI_FIXUP_CLASS_FINAL(PCI_VENDOR_ID_AMD, PCI_ANY_ID,
PCI_CLASS_MULTIMEDIA_HD_AUDIO, 8, quirk_gpu_hda);
DECLARE_PCI_FIXUP_CLASS_FINAL(PCI_VENDOR_ID_NVIDIA, PCI_ANY_ID,
PCI_CLASS_MULTIMEDIA_HD_AUDIO, 8, quirk_gpu_hda);
+
+/*
+ * Some IDT switches incorrectly flag an ACS Source Validation error on
+ * completions for config read requests even though PCIe r4.0, sec
+ * 6.12.1.1, says that completions are never affected by ACS Source
+ * Validation. Here's the text of IDT 89H32H8G3-YC, erratum #36:
+ *
+ * Item #36 - Downstream port applies ACS Source Validation to Completions
+ * Section 6.12.1.1 of the PCI Express Base Specification 3.1 states that
+ * completions are never affected by ACS Source Validation. However,
+ * completions received by a downstream port of the PCIe switch from a
+ * device that has not yet captured a PCIe bus number are incorrectly
+ * dropped by ACS Source Validation by the switch downstream port.
+ *
+ * The workaround suggested by IDT is to issue a config write to the
+ * downstream device before issuing the first config read. This allows the
+ * downstream device to capture its bus and device numbers (see PCIe r4.0,
+ * sec 2.2.9), thus avoiding the ACS error on the completion.
+ *
+ * However, we don't know when the device is ready to accept the config
+ * write, so we do config reads until we receive a non-Config Request Retry
+ * Status, then do the config write.
+ *
+ * To avoid hitting the erratum when doing the config reads, we disable ACS
+ * SV around this process.
+ */
+int pci_idt_bus_quirk(struct pci_bus *bus, int devfn, u32 *l, int timeout)
+{
+ int pos;
+ u16 ctrl = 0;
+ bool found;
+ struct pci_dev *bridge = bus->self;
+
+ pos = pci_find_ext_capability(bridge, PCI_EXT_CAP_ID_ACS);
+
+ /* Disable ACS SV before initial config reads */
+ if (pos) {
+ pci_read_config_word(bridge, pos + PCI_ACS_CTRL, &ctrl);
+ if (ctrl & PCI_ACS_SV)
+ pci_write_config_word(bridge, pos + PCI_ACS_CTRL,
+ ctrl & ~PCI_ACS_SV);
+ }
+
+ found = pci_bus_generic_read_dev_vendor_id(bus, devfn, l, timeout);
+
+ /* Write Vendor ID (read-only) so the endpoint latches its bus/dev */
+ if (found)
+ pci_bus_write_config_word(bus, devfn, PCI_VENDOR_ID, 0);
+
+ /* Re-enable ACS_SV if it was previously enabled */
+ if (ctrl & PCI_ACS_SV)
+ pci_write_config_word(bridge, pos + PCI_ACS_CTRL, ctrl);
+
+ return found;
+}
OpenPOWER on IntegriCloud