diff --git a/drivers/hwmon/it87.c b/drivers/hwmon/it87.c
index 1002befd87d5..5be09c048c5f 100644
--- a/drivers/hwmon/it87.c
+++ b/drivers/hwmon/it87.c
@@ -539,14 +539,14 @@ static ssize_t set_sensor(struct device *dev, struct device_attribute *attr,
struct it87_data *data = dev_get_drvdata(dev);
long val;
+ u8 reg;
if (strict_strtol(buf, 10, &val) < 0)
return -EINVAL;
- mutex_lock(&data->update_lock);
-
- data->sensor &= ~(1 << nr);
- data->sensor &= ~(8 << nr);
+ reg = it87_read_value(data, IT87_REG_TEMP_ENABLE);
+ reg &= ~(1 << nr);
+ reg &= ~(8 << nr);
if (val == 2) { /* backwards compatibility */
dev_warn(dev, "Sensor type 2 is deprecated, please use 4 "
"instead\n");
@@ -554,14 +554,16 @@ static ssize_t set_sensor(struct device *dev, struct device_attribute *attr,
}
/* 3 = thermal diode; 4 = thermistor; 0 = disabled */
if (val == 3)
- data->sensor |= 1 << nr;
+ reg |= 1 << nr;
else if (val == 4)
- data->sensor |= 8 << nr;
- else if (val != 0) {
- mutex_unlock(&data->update_lock);
+ reg |= 8 << nr;
+ else if (val != 0)
return -EINVAL;
- }
+
+ mutex_lock(&data->update_lock);
+ data->sensor = reg;
it87_write_value(data, IT87_REG_TEMP_ENABLE, data->sensor);
+ data->valid = 0; /* Force cache refresh */
mutex_unlock(&data->update_lock);
return count;
}
@@ -1841,14 +1843,10 @@ static void __devinit it87_init_device(struct platform_device *pdev)
it87_write_value(data, IT87_REG_TEMP_HIGH(i), 127);
}
- /* Check if temperature channels are reset manually or by some reason */
- tmp = it87_read_value(data, IT87_REG_TEMP_ENABLE);
- if ((tmp & 0x3f) == 0) {
- /* Temp1,Temp3=thermistor; Temp2=thermal diode */
- tmp = (tmp & 0xc0) | 0x2a;
- it87_write_value(data, IT87_REG_TEMP_ENABLE, tmp);
- }
- data->sensor = tmp;
+ /* Temperature channels are not forcibly enabled, as they can be
+ * set to two different sensor types and we can't guess which one
+ * is correct for a given system. These channels can be enabled at
+ * run-time through the temp{1-3}_type sysfs accessors if needed. */
/* Check if voltage monitors are reset manually or by some reason */
tmp = it87_read_value(data, IT87_REG_VIN_ENABLE);