summaryrefslogtreecommitdiffstats
path: root/arch/arm/mach-u300/regulator.c
diff options
context:
space:
mode:
Diffstat (limited to 'arch/arm/mach-u300/regulator.c')
-rw-r--r--arch/arm/mach-u300/regulator.c88
1 files changed, 88 insertions, 0 deletions
diff --git a/arch/arm/mach-u300/regulator.c b/arch/arm/mach-u300/regulator.c
new file mode 100644
index 000000000000..9c53f01c62eb
--- /dev/null
+++ b/arch/arm/mach-u300/regulator.c
@@ -0,0 +1,88 @@
+/*
+ * arch/arm/mach-u300/regulator.c
+ *
+ * Copyright (C) 2009 ST-Ericsson AB
+ * License terms: GNU General Public License (GPL) version 2
+ * Handle board-bound regulators and board power not related
+ * to any devices.
+ * Author: Linus Walleij <linus.walleij@stericsson.com>
+ */
+#include <linux/device.h>
+#include <linux/signal.h>
+#include <linux/err.h>
+#include <linux/regulator/consumer.h>
+/* Those are just for writing in syscon */
+#include <linux/io.h>
+#include <mach/hardware.h>
+#include <mach/syscon.h>
+
+/*
+ * Regulators that power the board and chip and which are
+ * not copuled to specific drivers are hogged in these
+ * instances.
+ */
+static struct regulator *main_power_15;
+
+/*
+ * This function is used from pm.h to shut down the system by
+ * resetting all regulators in turn and then disable regulator
+ * LDO D (main power).
+ */
+void u300_pm_poweroff(void)
+{
+ sigset_t old, all;
+
+ sigfillset(&all);
+ if (!sigprocmask(SIG_BLOCK, &all, &old)) {
+ /* Disable LDO D to shut down the system */
+ if (main_power_15)
+ regulator_disable(main_power_15);
+ else
+ pr_err("regulator not available to shut down system\n");
+ (void) sigprocmask(SIG_SETMASK, &old, NULL);
+ }
+ return;
+}
+
+/*
+ * Hog the regulators needed to power up the board.
+ */
+static int __init u300_init_boardpower(void)
+{
+ int err;
+ u32 val;
+
+ pr_info("U300: setting up board power\n");
+ main_power_15 = regulator_get(NULL, "vana15");
+ if (IS_ERR(main_power_15)) {
+ pr_err("could not get vana15");
+ return PTR_ERR(main_power_15);
+ }
+ err = regulator_enable(main_power_15);
+ if (err) {
+ pr_err("could not enable vana15\n");
+ return err;
+ }
+
+ /*
+ * On U300 a special system controller register pulls up the DC
+ * until the vana15 (LDO D) regulator comes up. At this point, all
+ * regulators are set and we do not need power control via
+ * DC ON anymore. This function will likely be moved whenever
+ * the rest of the U300 power management is implemented.
+ */
+ pr_info("U300: disable system controller pull-up\n");
+ val = readw(U300_SYSCON_VBASE + U300_SYSCON_PMCR);
+ val &= ~U300_SYSCON_PMCR_DCON_ENABLE;
+ writew(val, U300_SYSCON_VBASE + U300_SYSCON_PMCR);
+
+ /* Register globally exported PM poweroff hook */
+ pm_power_off = u300_pm_poweroff;
+
+ return 0;
+}
+
+/*
+ * So at module init time we hog the regulator!
+ */
+module_init(u300_init_boardpower);
OpenPOWER on IntegriCloud