@@ -78,8 +78,13 @@ config SOC_OMAP3430
default y
select ARCH_OMAP_OTG
-config SOC_OMAPTI816X
- bool "TI816X support"
+config SOC_OMAPTI81XX
+ bool "TI81XX support"
+ depends on ARCH_OMAP3
+ default y
+
+config SOC_OMAPAM33XX
+ bool "AM33XX support"
depends on ARCH_OMAP3
default y
@@ -316,7 +321,12 @@ config MACH_OMAP_3630SDP
config MACH_TI8168EVM
bool "TI8168 Evaluation Module"
- depends on SOC_OMAPTI816X
+ depends on SOC_OMAPTI81XX
+ default y
+
+config MACH_TI8148EVM
+ bool "TI8148 Evaluation Module"
+ depends on SOC_OMAPTI81XX
default y
config MACH_OMAP_4430SDP
@@ -355,6 +365,27 @@ config OMAP3_SDRC_AC_TIMING
wish to say no. Selecting yes without understanding what is
going on could result in system crashes;
+config OMAP4_ERRATA_I688
+ bool "OMAP4 errata: Async Bridge Corruption"
+ depends on ARCH_OMAP4
+ select ARCH_HAS_BARRIERS
+ help
+ If a data is stalled inside asynchronous bridge because of back
+ pressure, it may be accepted multiple times, creating pointer
+ misalignment that will corrupt next transfers on that data path
+ until next reset of the system (No recovery procedure once the
+ issue is hit, the path remains consistently broken). Async bridge
+ can be found on path between MPU to EMIF and MPU to L3 interconnect.
+ This situation can happen only when the idle is initiated by a
+ Master Request Disconnection (which is trigged by software when
+ executing WFI on CPU).
+ The work-around for this errata needs all the initiators connected
+ through async bridge must ensure that data path is properly drained
+ before issuing WFI. This condition will be met if one Strongly ordered
+ access is performed to the target right before executing the WFI.
+ In MPU case, L3 T2ASYNC FIFO and DDR T2ASYNC FIFO needs to be drained.
+ IO barrier ensure that there is no synchronisation loss on initiators
+ operating on both interconnect port simultaneously.