summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/ABI')
-rw-r--r--Documentation/ABI/testing/sysfs-devices-power31
-rw-r--r--Documentation/ABI/testing/sysfs-devices-sun14
2 files changed, 45 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-devices-power b/Documentation/ABI/testing/sysfs-devices-power
index 45000f0db4d4..7fc2997b23a6 100644
--- a/Documentation/ABI/testing/sysfs-devices-power
+++ b/Documentation/ABI/testing/sysfs-devices-power
@@ -204,3 +204,34 @@ Description:
This attribute has no effect on system-wide suspend/resume and
hibernation.
+
+What: /sys/devices/.../power/pm_qos_no_power_off
+Date: September 2012
+Contact: Rafael J. Wysocki <rjw@sisk.pl>
+Description:
+ The /sys/devices/.../power/pm_qos_no_power_off attribute
+ is used for manipulating the PM QoS "no power off" flag. If
+ set, this flag indicates to the kernel that power should not
+ be removed entirely from the device.
+
+ Not all drivers support this attribute. If it isn't supported,
+ it is not present.
+
+ This attribute has no effect on system-wide suspend/resume and
+ hibernation.
+
+What: /sys/devices/.../power/pm_qos_remote_wakeup
+Date: September 2012
+Contact: Rafael J. Wysocki <rjw@sisk.pl>
+Description:
+ The /sys/devices/.../power/pm_qos_remote_wakeup attribute
+ is used for manipulating the PM QoS "remote wakeup required"
+ flag. If set, this flag indicates to the kernel that the
+ device is a source of user events that have to be signaled from
+ its low-power states.
+
+ Not all drivers support this attribute. If it isn't supported,
+ it is not present.
+
+ This attribute has no effect on system-wide suspend/resume and
+ hibernation.
diff --git a/Documentation/ABI/testing/sysfs-devices-sun b/Documentation/ABI/testing/sysfs-devices-sun
new file mode 100644
index 000000000000..86be9848a77e
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-devices-sun
@@ -0,0 +1,14 @@
+Whatt: /sys/devices/.../sun
+Date: October 2012
+Contact: Yasuaki Ishimatsu <isimatu.yasuaki@jp.fujitsu.com>
+Description:
+ The file contains a Slot-unique ID which provided by the _SUN
+ method in the ACPI namespace. The value is written in Advanced
+ Configuration and Power Interface Specification as follows:
+
+ "The _SUN value is required to be unique among the slots of
+ the same type. It is also recommended that this number match
+ the slot number printed on the physical slot whenever possible."
+
+ So reading the sysfs file, we can identify a physical position
+ of the slot in the system.
OpenPOWER on IntegriCloud