summaryrefslogtreecommitdiffstats
path: root/net/wireless/mlme.c
diff options
context:
space:
mode:
authorJohannes Berg <johannes.berg@intel.com>2012-06-16 00:19:54 +0200
committerJohannes Berg <johannes.berg@intel.com>2012-08-20 13:58:21 +0200
commit98104fdeda63d57631c9f89e90a7b83b58fcee40 (patch)
tree22d0f75c2f369fd02695ea8051ddc68e6f8b8390 /net/wireless/mlme.c
parentcc74c0c7d6d623d0d3f13ef64895937edb7b3177 (diff)
downloadtalos-op-linux-98104fdeda63d57631c9f89e90a7b83b58fcee40.tar.gz
talos-op-linux-98104fdeda63d57631c9f89e90a7b83b58fcee40.zip
cfg80211: add P2P Device abstraction
In order to support using a different MAC address for the P2P Device address we must first have a P2P Device abstraction that can be assigned a MAC address. This abstraction will also be useful to support offloading P2P operations to the device, e.g. periodic listen for discoverability. Currently, the driver is responsible for assigning a MAC address to the P2P Device, but this could be changed by allowing a MAC address to be given to the NEW_INTERFACE command. As it has no associated netdev, a P2P Device can only be identified by its wdev identifier but the previous patches allowed using the wdev identifier in various APIs, e.g. remain-on-channel. Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Diffstat (limited to 'net/wireless/mlme.c')
-rw-r--r--net/wireless/mlme.c10
1 files changed, 7 insertions, 3 deletions
diff --git a/net/wireless/mlme.c b/net/wireless/mlme.c
index 1cdb1d5e6b0f..8fd0242ee169 100644
--- a/net/wireless/mlme.c
+++ b/net/wireless/mlme.c
@@ -736,7 +736,6 @@ int cfg80211_mlme_mgmt_tx(struct cfg80211_registered_device *rdev,
const u8 *buf, size_t len, bool no_cck,
bool dont_wait_for_ack, u64 *cookie)
{
- struct net_device *dev = wdev->netdev;
const struct ieee80211_mgmt *mgmt;
u16 stype;
@@ -796,7 +795,7 @@ int cfg80211_mlme_mgmt_tx(struct cfg80211_registered_device *rdev,
case NL80211_IFTYPE_AP:
case NL80211_IFTYPE_P2P_GO:
case NL80211_IFTYPE_AP_VLAN:
- if (!ether_addr_equal(mgmt->bssid, dev->dev_addr))
+ if (!ether_addr_equal(mgmt->bssid, wdev_address(wdev)))
err = -EINVAL;
break;
case NL80211_IFTYPE_MESH_POINT:
@@ -809,6 +808,11 @@ int cfg80211_mlme_mgmt_tx(struct cfg80211_registered_device *rdev,
* cfg80211 doesn't track the stations
*/
break;
+ case NL80211_IFTYPE_P2P_DEVICE:
+ /*
+ * fall through, P2P device only supports
+ * public action frames
+ */
default:
err = -EOPNOTSUPP;
break;
@@ -819,7 +823,7 @@ int cfg80211_mlme_mgmt_tx(struct cfg80211_registered_device *rdev,
return err;
}
- if (!ether_addr_equal(mgmt->sa, dev->dev_addr))
+ if (!ether_addr_equal(mgmt->sa, wdev_address(wdev)))
return -EINVAL;
/* Transmit the Action frame as requested by user space */
OpenPOWER on IntegriCloud