summaryrefslogtreecommitdiffstats
path: root/drivers/usb
diff options
context:
space:
mode:
authorMathias Nyman <mathias.nyman@linux.intel.com>2014-06-24 17:14:40 +0300
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2014-06-24 12:29:35 -0400
commit6fcfb0d682a8212d321a6131adc94daf0905992a (patch)
tree92c42c45ff79599d505b0a86c601662f47701ad8 /drivers/usb
parent135e7d0d4a488df06c2301c74e190a8aff6f75ab (diff)
downloadtalos-op-linux-6fcfb0d682a8212d321a6131adc94daf0905992a.tar.gz
talos-op-linux-6fcfb0d682a8212d321a6131adc94daf0905992a.zip
xhci: Use correct SLOT ID when handling a reset device command
Command completion events normally include command completion status, SLOT_ID, and a pointer to the original command. Reset device command completion SLOT_ID may be zero according to xhci specs 4.6.11. VIA controllers set the SLOT_ID to zero, triggering a WARN_ON in the command completion handler. Use the SLOT ID found from the original command instead. This patch should be applied to stable kernels since 3.13 that contain the commit 20e7acb13ff48fbc884d5918c3697c27de63922a "xhci: use completion event's slot id rather than dig it out of command" Cc: stable@vger.kernel.org # 3.13 Reported-by: Saran Neti <sarannmr@gmail.com> Tested-by: Saran Neti <sarannmr@gmail.com> Signed-off-by: Mathias Nyman <mathias.nyman@linux.intel.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'drivers/usb')
-rw-r--r--drivers/usb/host/xhci-ring.c7
1 files changed, 5 insertions, 2 deletions
diff --git a/drivers/usb/host/xhci-ring.c b/drivers/usb/host/xhci-ring.c
index d67ff71209f5..71657d39a578 100644
--- a/drivers/usb/host/xhci-ring.c
+++ b/drivers/usb/host/xhci-ring.c
@@ -1433,8 +1433,11 @@ static void handle_cmd_completion(struct xhci_hcd *xhci,
xhci_handle_cmd_reset_ep(xhci, slot_id, cmd_trb, cmd_comp_code);
break;
case TRB_RESET_DEV:
- WARN_ON(slot_id != TRB_TO_SLOT_ID(
- le32_to_cpu(cmd_trb->generic.field[3])));
+ /* SLOT_ID field in reset device cmd completion event TRB is 0.
+ * Use the SLOT_ID from the command TRB instead (xhci 4.6.11)
+ */
+ slot_id = TRB_TO_SLOT_ID(
+ le32_to_cpu(cmd_trb->generic.field[3]));
xhci_handle_cmd_reset_dev(xhci, slot_id, event);
break;
case TRB_NEC_GET_FW:
OpenPOWER on IntegriCloud