authorVaibhav Hiremath <hvaibhav@ti.com>2012-09-03 11:50:36 -0600
committerPaul Walmsley <paul@pwsan.com>2012-09-03 11:50:36 -0600
commit577650139062dcc20246da3f61e0bdafc65edf8f (patch)
tree0134658d4b26ba7d9aa488fea067b0a14c650618 /arch/arm
parent4cbe5a555fa58a79b6ecbb6c531b8bab0650778d (diff)
downloadtalos-op-linux-577650139062dcc20246da3f61e0bdafc65edf8f.tar.gz
talos-op-linux-577650139062dcc20246da3f61e0bdafc65edf8f.zip
ARM: OMAP2+: am33xx: Fix the timer fck clock naming convention
With commit ae6df418a21f3a361c5f9b878e32a8aba4e17692 Sub: ARM: OMAP2+: dmtimer: cleanup fclk usage) The Timer functional clock naming convention has changed from gptX_fck => timerXfck, and so as the timer init function in mach-omap2/timer.c. OMAP4 clocktree also has changed accordingly. AM33xx Clock Tree has been merged during rc3-4 timeframe, before above commit got merged, so similar change is required for AM33xx as well (Change the gptX_fck => timerX_fck). Signed-off-by: Vaibhav Hiremath <hvaibhav@ti.com> Signed-off-by: Paul Walmsley <paul@pwsan.com>
Diffstat (limited to 'arch/arm')
-rw-r--r--arch/arm/mach-omap2/clock33xx_data.c14
1 files changed, 7 insertions, 7 deletions
diff --git a/arch/arm/mach-omap2/clock33xx_data.c b/arch/arm/mach-omap2/clock33xx_data.c
index 25bbcc7ca4dc..ae27de8899a6 100644
--- a/arch/arm/mach-omap2/clock33xx_data.c
+++ b/arch/arm/mach-omap2/clock33xx_data.c
@@ -1036,13 +1036,13 @@ static struct omap_clk am33xx_clks[] = {
CLK(NULL, "mmu_fck", &mmu_fck, CK_AM33XX),
CLK(NULL, "smartreflex0_fck", &smartreflex0_fck, CK_AM33XX),
CLK(NULL, "smartreflex1_fck", &smartreflex1_fck, CK_AM33XX),
- CLK(NULL, "gpt1_fck", &timer1_fck, CK_AM33XX),
- CLK(NULL, "gpt2_fck", &timer2_fck, CK_AM33XX),
- CLK(NULL, "gpt3_fck", &timer3_fck, CK_AM33XX),
- CLK(NULL, "gpt4_fck", &timer4_fck, CK_AM33XX),
- CLK(NULL, "gpt5_fck", &timer5_fck, CK_AM33XX),
- CLK(NULL, "gpt6_fck", &timer6_fck, CK_AM33XX),
- CLK(NULL, "gpt7_fck", &timer7_fck, CK_AM33XX),
+ CLK(NULL, "timer1_fck", &timer1_fck, CK_AM33XX),
+ CLK(NULL, "timer2_fck", &timer2_fck, CK_AM33XX),
+ CLK(NULL, "timer3_fck", &timer3_fck, CK_AM33XX),
+ CLK(NULL, "timer4_fck", &timer4_fck, CK_AM33XX),
+ CLK(NULL, "timer5_fck", &timer5_fck, CK_AM33XX),
+ CLK(NULL, "timer6_fck", &timer6_fck, CK_AM33XX),
+ CLK(NULL, "timer7_fck", &timer7_fck, CK_AM33XX),
CLK(NULL, "usbotg_fck", &usbotg_fck, CK_AM33XX),
CLK(NULL, "ieee5000_fck", &ieee5000_fck, CK_AM33XX),
CLK(NULL, "wdt1_fck", &wdt1_fck, CK_AM33XX),