diff options
author | David S. Miller <davem@davemloft.net> | 2015-09-26 16:08:27 -0700 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2015-09-26 16:08:27 -0700 |
commit | 4963ed48f2c20196d51a447ee87dc2815584fee4 (patch) | |
tree | a1902f466dafa00453889a4f1e66b00249ce0529 /Documentation/thermal | |
parent | 4d54d86546f62c7c4a0fe3b36a64c5e3b98ce1a9 (diff) | |
parent | 518a7cb6980cd640c7f979d29021ad870f60d7d7 (diff) | |
download | talos-op-linux-4963ed48f2c20196d51a447ee87dc2815584fee4.tar.gz talos-op-linux-4963ed48f2c20196d51a447ee87dc2815584fee4.zip |
Merge git://git.kernel.org/pub/scm/linux/kernel/git/davem/net
Conflicts:
net/ipv4/arp.c
The net/ipv4/arp.c conflict was one commit adding a new
local variable while another commit was deleting one.
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'Documentation/thermal')
-rw-r--r-- | Documentation/thermal/power_allocator.txt | 2 | ||||
-rw-r--r-- | Documentation/thermal/sysfs-api.txt | 6 |
2 files changed, 7 insertions, 1 deletions
diff --git a/Documentation/thermal/power_allocator.txt b/Documentation/thermal/power_allocator.txt index c3797b529991..a1ce2235f121 100644 --- a/Documentation/thermal/power_allocator.txt +++ b/Documentation/thermal/power_allocator.txt @@ -4,7 +4,7 @@ Power allocator governor tunables Trip points ----------- -The governor requires the following two passive trip points: +The governor works optimally with the following two passive trip points: 1. "switch on" trip point: temperature above which the governor control loop starts operating. This is the first passive trip diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index c1f6864a8c5d..10f062ea6bc2 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt @@ -180,6 +180,7 @@ Thermal zone device sys I/F, created once it's registered: |---temp: Current temperature |---mode: Working mode of the thermal zone |---policy: Thermal governor used for this zone + |---available_policies: Available thermal governors for this zone |---trip_point_[0-*]_temp: Trip point temperature |---trip_point_[0-*]_type: Trip point type |---trip_point_[0-*]_hyst: Hysteresis value for this trip point @@ -256,6 +257,10 @@ policy One of the various thermal governors used for a particular zone. RW, Required +available_policies + Available thermal governors which can be used for a particular zone. + RO, Required + trip_point_[0-*]_temp The temperature above which trip point will be fired. Unit: millidegree Celsius @@ -417,6 +422,7 @@ method, the sys I/F structure will be built like this: |---temp: 37000 |---mode: enabled |---policy: step_wise + |---available_policies: step_wise fair_share |---trip_point_0_temp: 100000 |---trip_point_0_type: critical |---trip_point_1_temp: 80000 |