/* IBM_PROLOG_BEGIN_TAG */
/* This is an automatically generated prolog. */
/* */
/* $Source: src/occ_405/pss/avsbus.h $ */
/* */
/* OpenPOWER OnChipController Project */
/* */
/* Contributors Listed Below - COPYRIGHT 2011,2015 */
/* [+] International Business Machines Corp. */
/* */
/* */
/* Licensed under the Apache License, Version 2.0 (the "License"); */
/* you may not use this file except in compliance with the License. */
/* You may obtain a copy of the License at */
/* */
/* http://www.apache.org/licenses/LICENSE-2.0 */
/* */
/* Unless required by applicable law or agreed to in writing, software */
/* distributed under the License is distributed on an "AS IS" BASIS, */
/* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or */
/* implied. See the License for the specific language governing */
/* permissions and limitations under the License. */
/* */
/* IBM_PROLOG_END_TAG */
#ifndef _AVSBUS_H
#define _AVSBUS_H
#include <errl.h>
extern bool G_avsbus_vdd_monitoring;
extern bool G_avsbus_vdn_monitoring;
#define AVSBUS_STATUS_OVER_CURRENT_MASK 0x4000
#define AVSBUS_STATUS_UNDER_VOLTAGE_MASK 0x2000
#define AVSBUS_STATUS_OVER_TEMPERATURE_MASK 0x1000
#define AVSBUS_STATUS_OVER_POWER_MASK 0x0800
typedef enum
{
AVSBUS_VDD = 0x00,
AVSBUS_VDN = 0x01,
} avsbus_type_e;
typedef enum
{
// This enum contains the AVS Bus CmdDataType that can be read
AVSBUS_VOLTAGE = 0x00,
AVSBUS_CURRENT = 0x02,
AVSBUS_STATUS = 0x0E
} avsbus_cmdtype_e;
// Setup the AVS Bus for reading
void avsbus_init();
// Initiate AVS Bus read for specified cmdtype (Voltage / Current)
// (results can then be read on the next tick)
void initiate_avsbus_reads(avsbus_cmdtype_e i_cmdType);
// Process AVS Bus read results (or errors) for specified bus/cmdtype.
// Returns the data requested (voltage units are mV, current units are in 10mA)
// Predictive error will be logged after MAX_READ_ATTEMPTS failures on the specific
// bus/cmdtype and an OCC reset will be requested
uint16_t avsbus_read(const avsbus_type_e i_type,
const avsbus_cmdtype_e i_cmdtype);
// Initiate read of AVS Bus Status
// (results can then be read on the next tick)
void initiate_avsbus_read_status();
// Read the status from AVS Bus and return 1 if over-temperature was found for either bus
// or 0 if no OT was found. 0xFF will be returned if there was an error reading status
// on either bus. Mfg error will be logged for the first OT or first OC condition.
// Error history counters will be incremented for any over-temp/over-current condition.
uint8_t process_avsbus_status();
#endif //_AVSBUS_H
|