1 files changed, 88 insertions, 230 deletions
diff --git a/src/occ_405/pss/avsbus.c b/src/occ_405/pss/avsbus.c
index 620d376..f25f86e 100644
--- a/src/occ_405/pss/avsbus.c
+++ b/src/occ_405/pss/avsbus.c
@@ -35,6 +35,7 @@
#include "ssx.h"
#include "occ_util.h"
#include "cmdh_fsp_cmds_datacnfg.h"
+#include "common.h"
//#define AVSDEBUG
@@ -62,9 +63,12 @@ static bool G_trace_scoms = TRUE;
bool G_avsbus_vdd_monitoring = FALSE;
bool G_avsbus_vdn_monitoring = FALSE;
+// Vdd Current reading to check if it rolled over (0 when no roll over checking required)
+uint32_t G_check_vdd_current_10mA_for_rollover = 0;
+
+extern uint16_t G_allow_trace_flags;
extern uint32_t G_nest_frequency_mhz;
#define AVSBUS_FREQUENCY_MHZ 10
-extern bool G_vrm_thermal_monitoring;
extern bool G_vrm_vdd_temp_expired;
void amec_health_check_vrm_vdd_temp(const sensor_t *i_sensor);
@@ -114,8 +118,8 @@ uint32_t wait_for_complete(const uint8_t i_bus)
}
-// Clear OT/OC bit in status reg for both busses
-uint32_t deglitch_status_errors(const uint8_t i_bus, const uint32_t i_status_mask)
+// Clear bits i_status_mask in status reg for i_bus
+uint32_t clear_status_errors(const uint8_t i_bus, const uint32_t i_status_mask)
{
// Write O2SCMD[a][n]
// o2s_clear_sticky_bits = 1
@@ -123,12 +127,8 @@ uint32_t deglitch_status_errors(const uint8_t i_bus, const uint32_t i_status_mas
DEBUG_OUT32(OCB_O2SCMDxB[i_bus], value, "OCB_O2SCMDxB");
out32(OCB_O2SCMDxB[i_bus], value);
- // To deglitch the status bits, set the status bits you wish to clear with a 1. (in CmdData)
- // After the write completes, if the status is still active, then the
- // signal must be solid failure.
-
- TRAC_INFO("deglitch_status_errors(AVSBUS %d,0x%08X)", i_bus, i_status_mask);
- // AVS Bus command (write staus):
+ // To clear status bits write the status bits you wish to clear with a 1. (in CmdData)
+ // AVS Bus command (write status):
// 0:1 StartCode = 0b01
// 2:3 Cmd = 0b00 (write+commit)
// 4 CmdGroup = 0b0 (AVSBus)
@@ -138,7 +138,7 @@ uint32_t deglitch_status_errors(const uint8_t i_bus, const uint32_t i_status_mas
// 29:31 CRC
// 01000DDD DRRRRXXX XXXXXXXX XXXXXCCC
// 01000111 01111--- -------- -----CCC
- uint32_t cmd_data = AVSBUS_STATUS_OVER_CURRENT_MASK | AVSBUS_STATUS_OVER_TEMPERATURE_MASK;
+ uint32_t cmd_data = i_status_mask;
value = 0x47780000 | (cmd_data << 3);
// Calculate/add CRC
value |= avs_crc_calculate(value);
@@ -151,7 +151,7 @@ uint32_t deglitch_status_errors(const uint8_t i_bus, const uint32_t i_status_mas
// return the last read status
return l_status;
-} // end deglitch_status_errors()
+} // end clear_status_errors()
// Re-sync AVS bus to try to recover from errors
@@ -290,18 +290,17 @@ void avsbus_init()
out32(OCB_O2SCTRL21B, value);
}
- // Re-sync AVS bus and clear OC/OT masks in status regs and
- // De-glitch: clear OC/OT masks in the status reg
- const uint32_t error_mask = AVSBUS_STATUS_OVER_CURRENT_MASK | AVSBUS_STATUS_OVER_TEMPERATURE_MASK;
+ // Re-sync AVS bus and clear OC bits in status regs and
+ const uint32_t error_mask = AVSBUS_STATUS_OVER_CURRENT_MASK;
if (bus0_monitoring)
{
avsbus_resync(0);
- deglitch_status_errors(0, error_mask);
+ clear_status_errors(0, error_mask);
}
if (bus1_monitoring)
{
avsbus_resync(1);
- deglitch_status_errors(1, error_mask);
+ clear_status_errors(1, error_mask);
}
@@ -676,7 +675,6 @@ uint16_t avsbus_read(const avsbus_type_e i_type,
*l_error_count, l_trace_type, l_trace_cmd);
G_avsbus_vdd_monitoring = FALSE;
G_avsbus_vdn_monitoring = FALSE;
- G_vrm_thermal_monitoring = FALSE;
errlHndl_t l_err = createErrl(PSS_MID_AVSBUS_READ,
rc,
exrc,
@@ -728,7 +726,7 @@ void initiate_avsbus_reads(avsbus_cmdtype_e i_cmdType)
} // end initiate_avsbus_reads()
-// Initiate read for error status bits (over-temperature, over-current)
+// Initiate read for error status bits (over-current)
void initiate_avsbus_read_status()
{
if (isSafeStateRequested())
@@ -805,12 +803,10 @@ void initiate_avsbus_read_status()
// Process AVS Bus read status results (or errors)
-// Predictive error will be logged after "VRMs: max_read_timeout" failures
-// and a mfg error will be committed.
// Returns the status data or AVSBUS_STATUS_READ_ERROR on error
uint16_t avsbus_read_status(const avsbus_type_e i_type)
{
- if (isSafeStateRequested() || (G_vrm_thermal_monitoring == FALSE))
+ if (isSafeStateRequested())
{
// No need to process data if OCC will be reset
return 0;
@@ -977,243 +973,105 @@ uint16_t avsbus_read_status(const avsbus_type_e i_type)
} // end avsbus_read_status()
-// Read the status from AVS Bus and return 1 if over-temperature was found for either bus
-// or 0 if no OT was found. 0xFF will be returned if there was an error reading status.
-// Error history counters will be incremented for any over-temp/over-current condition.
-// Mfg error will be logged for the first OT or first OC condition.
-uint8_t process_avsbus_status()
+// Read the status from AVS Bus and apply Vdd current roll over workaround if needed
+// Error history counters will be incremented for any over-current condition.
+void process_avsbus_status()
{
- uint8_t foundOT = 0;
- uint8_t foundOC = 0;
uint16_t vdd_status = 0;
uint16_t vdn_status = 0;
- static bool L_vdd_ot_found = FALSE;
static bool L_vdd_oc_found = FALSE;
- static bool L_vdn_ot_found = FALSE;
static bool L_vdn_oc_found = FALSE;
- static bool L_vdd_ot_counted = FALSE;
- static bool L_vdd_oc_counted = FALSE;
- static bool L_vdn_ot_counted = FALSE;
- static bool L_vdn_oc_counted = FALSE;
- if (G_vrm_thermal_monitoring)
+ if (G_avsbus_vdd_monitoring)
{
- if (G_avsbus_vdd_monitoring)
+ vdd_status = avsbus_read_status(AVSBUS_VDD);
+ if (vdd_status != AVSBUS_STATUS_READ_ERROR)
{
- vdd_status = avsbus_read_status(AVSBUS_VDD);
- if (vdd_status != AVSBUS_STATUS_READ_ERROR)
+ if ((vdd_status & AVSBUS_STATUS_OVER_CURRENT_MASK) == 0)
{
- if ((vdd_status & (AVSBUS_STATUS_OVER_TEMPERATURE_MASK|AVSBUS_STATUS_OVER_CURRENT_MASK)) == 0)
+ // No OC errors found
+ if (L_vdd_oc_found)
{
- // No OT/OC errors found
- if (L_vdd_ot_found) TRAC_INFO("process_avsbus_status: Vdd OT cleared");
- L_vdd_ot_found = FALSE;
- L_vdd_ot_counted = FALSE;
- if (L_vdd_oc_found) TRAC_INFO("process_avsbus_status: Vdd OC cleared");
L_vdd_oc_found = FALSE;
- L_vdd_oc_counted = FALSE;
- }
- else
- {
- // Deglitch error if needed
- uint32_t deglitch_mask = 0;
- if ((vdd_status & AVSBUS_STATUS_OVER_TEMPERATURE_MASK) && (!L_vdd_ot_found))
- {
- deglitch_mask |= AVSBUS_STATUS_OVER_TEMPERATURE_MASK;
- L_vdd_ot_found = TRUE;
- }
- if ((vdd_status & AVSBUS_STATUS_OVER_CURRENT_MASK) && (!L_vdd_oc_found))
- {
- deglitch_mask |= AVSBUS_STATUS_OVER_CURRENT_MASK;
- L_vdd_oc_found = TRUE;
- }
- if (deglitch_mask)
- {
- // Deglitch error bit(s)
- deglitch_status_errors(G_sysConfigData.avsbus_vdd.bus, deglitch_mask);
-
- // Clear error bit(s) since could be false reading
- vdd_status &= (~deglitch_mask);
- }
-
- // Process error (if already deglitched)
- if (vdd_status & AVSBUS_STATUS_OVER_TEMPERATURE_MASK)
- {
- foundOT = 1;
- if (!L_vdd_ot_counted)
- {
- INCREMENT_ERR_HISTORY(ERRH_AVSBUS_VDD_OVER_TEMPERATURE);
- L_vdd_ot_counted = TRUE;
- }
- }
- else
- {
- L_vdd_ot_counted = FALSE;
- }
-
- if (vdd_status & AVSBUS_STATUS_OVER_CURRENT_MASK)
- {
- foundOC = 1;
- if (!L_vdd_oc_counted)
- {
- INCREMENT_ERR_HISTORY(ERRH_AVSBUS_VDD_OVER_CURRENT);
- L_vdd_oc_counted = TRUE;
- }
- }
- else
- {
- L_vdd_oc_counted = FALSE;
- }
+
+ if(G_allow_trace_flags & ALLOW_AVSBUS_TRACE)
+ TRAC_INFO("process_avsbus_status: Vdd OC cleared");
}
}
- else
+ else // Over current warning bit is set
{
- // 0xFF indicates error reading status
- foundOT = 0xFF;
+ INCREMENT_ERR_HISTORY(ERRH_AVSBUS_VDD_OVER_CURRENT);
+ L_vdd_oc_found = TRUE;
}
- }
- if (G_avsbus_vdn_monitoring)
- {
- vdn_status = avsbus_read_status(AVSBUS_VDN);
- if (vdn_status != AVSBUS_STATUS_READ_ERROR)
+
+ // Was updating Vdd Current sensor on hold to check if the reading rolled over?
+ if (G_check_vdd_current_10mA_for_rollover)
{
- if ((vdn_status & (AVSBUS_STATUS_OVER_TEMPERATURE_MASK|AVSBUS_STATUS_OVER_CURRENT_MASK)) == 0)
- {
- // No OT/OC errors found
- if (L_vdn_ot_found) TRAC_INFO("process_avsbus_status: Vdn OT cleared");
- L_vdn_ot_found = FALSE;
- L_vdn_ot_counted = FALSE;
- if (L_vdn_oc_found) TRAC_INFO("process_avsbus_status: Vdn OC cleared");
- L_vdn_oc_found = FALSE;
- L_vdn_oc_counted = FALSE;
- }
- else
+ uint32_t l_current = G_check_vdd_current_10mA_for_rollover;
+
+ // over current bit gets set when there is a roll over
+ if (L_vdd_oc_found)
{
- // Deglitch error if needed
- uint32_t deglitch_mask = 0;
- if ((vdn_status & AVSBUS_STATUS_OVER_TEMPERATURE_MASK) && (!L_vdn_ot_found))
- {
- deglitch_mask |= AVSBUS_STATUS_OVER_TEMPERATURE_MASK;
- L_vdn_ot_found = TRUE;
- }
- if ((vdn_status & AVSBUS_STATUS_OVER_CURRENT_MASK) && (!L_vdn_oc_found))
- {
- deglitch_mask |= AVSBUS_STATUS_OVER_CURRENT_MASK;
- L_vdn_oc_found = TRUE;
- }
- if (deglitch_mask)
- {
- // Deglitch error bit(s)
- deglitch_status_errors(G_sysConfigData.avsbus_vdn.bus, deglitch_mask);
-
- // Clear error bit(s) since could be false reading
- vdn_status &= (~deglitch_mask);
- }
-
- // Process error (if already deglitched)
- if (vdn_status & AVSBUS_STATUS_OVER_TEMPERATURE_MASK)
- {
- // if no Vdd error, update OT result
- if (foundOT != 0xFF)
+ // add the rollover point (from AVSbus config data) to the Current reading
+ l_current += G_sysConfigData.vdd_current_rollover_10mA;
+ // sanity check for valid rollover, make sure it isn't over the theoretical max (from AVSbus config data)
+ if(l_current > G_sysConfigData.vdd_max_current_10mA)
+ {
+ // went over the theoretical max don't apply the roll over
+ INCREMENT_ERR_HISTORY(ERRH_VDD_CURRENT_ROLLOVER_MAX);
+
+ if(G_allow_trace_flags & ALLOW_AVSBUS_TRACE)
{
- foundOT = 1;
+ TRAC_INFO("process_avsbus_status: Current with rollover %d > %d max",
+ l_current, G_sysConfigData.vdd_max_current_10mA);
}
- if (!L_vdn_ot_counted)
- {
- INCREMENT_ERR_HISTORY(ERRH_AVSBUS_VDN_OVER_TEMPERATURE);
- L_vdn_ot_counted = TRUE;
- }
- }
- else
- {
- L_vdn_ot_counted = FALSE;
- }
-
- if (vdn_status & AVSBUS_STATUS_OVER_CURRENT_MASK)
- {
- foundOC = 1;
- if (!L_vdn_oc_counted)
- {
- INCREMENT_ERR_HISTORY(ERRH_AVSBUS_VDN_OVER_CURRENT);
- L_vdn_oc_counted = TRUE;
- }
- }
- else
- {
- L_vdn_oc_counted = FALSE;
- }
+ l_current = G_check_vdd_current_10mA_for_rollover;
+ }
}
- }
- else
- {
- // 0xFF indicates error reading status
- foundOT = 0xFF;
+
+ // Now it is ok to update the sensor with Current value in unit 10mA
+ sensor_update(AMECSENSOR_PTR(CURVDD), (uint16_t)l_current);
+
+ // Update the chip voltage and power sensors after every current reading
+ update_avsbus_power_sensors(AVSBUS_VDD);
+
+ // clear so we know we have a new reading next time
+ G_check_vdd_current_10mA_for_rollover = 0;
}
}
-
- // Log an error the first time either condition is asserted
- static bool loggedOT = FALSE;
- static bool loggedOC = FALSE;
- errlHndl_t l_err;
- if ((foundOT == 1) && !loggedOT && G_vrm_thermal_monitoring)
+ else
{
- loggedOT = TRUE;
- TRAC_ERR("process_avsbus_status: AVSBUS Over Temperature Warning (Vdd: 0x%08X, Vdn: 0x%08X)",
- vdd_status, vdn_status);
- /* @
- * @errortype
- * @moduleid PSS_MID_AVSBUS_READ
- * @reasoncode VRM_VRFAN_WARNING
- * @userdata1 Vdd Status
- * @userdata2 Vdn Status
- * @devdesc VRFAN / over-temperature asserted
- */
- l_err = createErrl(PSS_MID_AVSBUS_READ,
- VRM_VRFAN_WARNING,
- OCC_NO_EXTENDED_RC,
- ERRL_SEV_INFORMATIONAL,
- NULL,
- DEFAULT_TRACE_SIZE,
- vdd_status, vdn_status);
- setErrlActions(l_err, ERRL_ACTIONS_MANUFACTURING_ERROR);
- // add processor callout
- addCalloutToErrl(l_err,
- ERRL_CALLOUT_TYPE_HUID,
- G_sysConfigData.proc_huid,
- ERRL_CALLOUT_PRIORITY_MED);
- commitErrl(&l_err);
+ // error reading status
+ INCREMENT_ERR_HISTORY(ERRH_AVSBUS_VDD_STATUS_READ_FAIL);
}
- if ((foundOC == 1) && !loggedOC)
+ }
+ if (G_avsbus_vdn_monitoring)
+ {
+ vdn_status = avsbus_read_status(AVSBUS_VDN);
+ if (vdn_status != AVSBUS_STATUS_READ_ERROR)
{
- loggedOC = TRUE;
- TRAC_ERR("process_avsbus_status: AVSBUS Over Current Warning (Vdd: 0x%08X, Vdn: 0x%08X)",
- vdd_status, vdn_status);
- /* @
- * @errortype
- * @moduleid PSS_MID_AVSBUS_READ
- * @reasoncode VRM_OVER_CURRENT_WARNING
- * @userdata1 Vdd Status
- * @userdata2 Vdn Status
- * @devdesc Output over-current asserted
- */
- l_err = createErrl(PSS_MID_AVSBUS_READ,
- VRM_OVER_CURRENT_WARNING,
- OCC_NO_EXTENDED_RC,
- ERRL_SEV_INFORMATIONAL,
- NULL,
- DEFAULT_TRACE_SIZE,
- vdd_status, vdn_status);
- setErrlActions(l_err, ERRL_ACTIONS_MANUFACTURING_ERROR);
- // add processor callout
- addCalloutToErrl(l_err,
- ERRL_CALLOUT_TYPE_HUID,
- G_sysConfigData.proc_huid,
- ERRL_CALLOUT_PRIORITY_MED);
- commitErrl(&l_err);
+ if ((vdn_status & AVSBUS_STATUS_OVER_CURRENT_MASK) == 0)
+ {
+ // No OC errors found
+ if (L_vdn_oc_found) TRAC_INFO("process_avsbus_status: Vdn OC cleared");
+ L_vdn_oc_found = FALSE;
+ }
+ else // Over current warning bit is set
+ {
+ INCREMENT_ERR_HISTORY(ERRH_AVSBUS_VDN_OVER_CURRENT);
+ L_vdn_oc_found = TRUE;
+ // Clear the over current error bit so we get a new read next time
+ clear_status_errors(G_sysConfigData.avsbus_vdn.bus, AVSBUS_STATUS_OVER_CURRENT_MASK);
+ }
+ }
+ else
+ {
+ // error reading status
+ INCREMENT_ERR_HISTORY(ERRH_AVSBUS_VDN_STATUS_READ_FAIL);
}
}
- return foundOT;
+ return;
} // end process_avsbus_status()